Measured moisture in buildings and adverse health effects: A review.

Abstract:

:It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified 3 eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose-related increases in asthma exacerbation with higher measured moisture, with 1 study reporting an adjusted odds ratio of 7.0 for night-time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera-determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted odds ratio of 14.5 for water-damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured "water activity," which directly assesses moisture availability for microbial growth. Ultimately, evidence-based, health-related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings.

journal_name

Indoor Air

journal_title

Indoor air

authors

Mendell MJ,Macher JM,Kumagai K

doi

10.1111/ina.12464

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

488-499

issue

4

eissn

0905-6947

issn

1600-0668

journal_volume

28

pub_type

杂志文章,评审
  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Comparing zonal and CFD model predictions of isothermal indoor airflows to experimental data.

    abstract::It is inappropriate to use the assumption of instantaneously well-mixed zones to model airflows and pollutant transport in large indoor spaces. We investigate two approaches for describing the details of airflows in large indoor spaces, for accuracy and suitability for integration with multi-zone infiltration models. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00160.x

    authors: Mora L,Gadgil AJ,Wurtz E

    更新日期:2003-06-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Olfactory detection of ozone and D-limonene: reactants in indoor spaces.

    abstract:UNLABELLED:Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00476.x

    authors: Cain WS,Schmidt R,Wolkoff P

    更新日期:2007-10-01 00:00:00

  • Exercise-induced effects on a gym atmosphere.

    abstract::We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity,...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12226

    authors: Žitnik M,Bučar K,Hiti B,Barba Ž,Rupnik Z,Založnik A,Žitnik E,Rodrìguez L,Mihevc I,Žibert J

    更新日期:2016-06-01 00:00:00

  • Quantitative measurement of airborne cockroach allergen in New York City apartments.

    abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00728.x

    authors: Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

    更新日期:2011-12-01 00:00:00

  • Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena.

    abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00316.x

    authors: Ataka Y,Kato S,Murakami S,Zhu Q,Ito K,Yokota T

    更新日期:2004-01-01 00:00:00

  • Assessment of indoor HONO formation mechanisms based on in situ measurements and modeling.

    abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12320

    authors: Mendez M,Blond N,Amedro D,Hauglustaine DA,Blondeau P,Afif C,Fittschen C,Schoemaecker C

    更新日期:2017-03-01 00:00:00

  • Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

    abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00183.x

    authors: Sohn MD,Sextro RG,Gadgil AJ,Daisey JM

    更新日期:2003-09-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • Quantitative aerobiologic analysis of an influenza human challenge-transmission trial.

    abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12701

    authors: Bueno de Mesquita PJ,Noakes CJ,Milton DK

    更新日期:2020-11-01 00:00:00

  • Effects of cigarette smoking and biomass fuel on lung function and respiratory symptoms in middle-aged adults and the elderly in Guangdong province, China: A cross-sectional study.

    abstract::We sought to investigate the association between active cigarette smoking (ex- and current smokers) with or without exposure to biomass fuels and respiratory symptoms/lung function in middle-aged adults and the elderly. In the chronic obstructive pulmonary disease surveillance conducted in six cities of Guangdong prov...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12671

    authors: Zheng XY,Li ZL,Li C,Guan WJ,Li LX,Xu YJ

    更新日期:2020-09-01 00:00:00

  • Levels and sources of volatile organic compounds in homes of children with asthma.

    abstract:UNLABELLED:Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total targe...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12086

    authors: Chin JY,Godwin C,Parker E,Robins T,Lewis T,Harbin P,Batterman S

    更新日期:2014-08-01 00:00:00

  • Indoor visible mold and mold odor are associated with new-onset childhood wheeze in a dose-dependent manner.

    abstract::Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with ne...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12413

    authors: Shorter C,Crane J,Pierse N,Barnes P,Kang J,Wickens K,Douwes J,Stanley T,Täubel M,Hyvärinen A,Howden-Chapman P,Wellington Region General Practitioner Research Network.

    更新日期:2018-01-01 00:00:00

  • Indoor and outdoor concentrations and determinants of NO2 in a cohort of 1-year-old children in Valencia, Spain.

    abstract:UNLABELLED:Nitrogen dioxide (NO2) is produced from the exhausts of vehicles and gas appliances and is known to pose certain health risks. In this study, we characterize the exposure to this substance during the first year of life, which is an important period of development. To this end, we used passive samplers to mea...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00646.x

    authors: Esplugues A,Ballester F,Estarlich M,Llop S,Fuentes V,Mantilla E,Iñiguez C

    更新日期:2010-06-01 00:00:00

  • Productivity and fatigue.

    abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00281.x

    authors: Tanabe S,Nishihara N

    更新日期:2004-01-01 00:00:00

  • Association of gas cooking with children's respiratory health: results from GINIplus and LISAplus birth cohort studies.

    abstract:UNLABELLED:Previous studies have found inconsistent results on the association between asthma in children and gas cooking emissions. We aimed to assess the effects of the long-term exposure to gas cooking on the onset of asthma and respiratory symptoms, focusing on wheezing, in children from two German birth cohorts: L...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00784.x

    authors: Casas L,Tischer C,Tiesler C,Brüske I,Koletzko S,Bauer CP,Wichmann HE,von Berg A,Berdel D,Krämer U,Schaaf B,Lehmann I,Herbarth O,Heinrich J,GINIplus and LISAplus Study Group.

    更新日期:2012-12-01 00:00:00

  • A review of ventilation and the quality of ventilation air.

    abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0668.2000.010003193.x

    authors: Liddament MW

    更新日期:2000-09-01 00:00:00

  • Comparison of risk factor profiles concerning self-reported skin complaints and objectively determined skin symptoms in German office workers.

    abstract::The correspondence between impact factor profiles of self-reported skin sensation and of objectively determined skin symptoms was examined using data from the ProKlimA project (1994-1999). A sub-sample of 925 office workers participated in measurements of skin hydration and sebum content and responded to a questionnai...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00222.x

    authors: Brasche S,Bullinger M,Schwab R,Gebhardt H,Herzog V,Bischof W

    更新日期:2004-04-01 00:00:00

  • Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons.

    abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00419.x

    authors: Kujundzic E,Hernandez M,Miller SL

    更新日期:2006-06-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • Particle dose estimation from frying in residential settings.

    abstract:UNLABELLED:Fumes produced during frying have been implicated as a potential cause for the increased incidence of adenocarcinoma. Particulate matter exposure has also been linked with other pulmonary and coronary disease. This study investigated the contribution of frying in residential settings to ultrafine and fine pa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00551.x

    authors: Evans GJ,Peers A,Sabaliauskas K

    更新日期:2008-12-01 00:00:00

  • Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system.

    abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00248.x

    authors: Chao CY,Wan MP

    更新日期:2004-10-01 00:00:00

  • Hygroscopic fine mode particle deposition on electronic circuits and resulting degradation of circuit performance: an experimental study.

    abstract::A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010001047.x

    authors: Litvak A,Gadgil AJ,Fisk WJ

    更新日期:2000-03-01 00:00:00

  • Determination of radon exhalation from construction materials using VOC emission test chambers.

    abstract::The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available me...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12031

    authors: Richter M,Jann O,Kemski J,Schneider U,Krocker C,Hoffmann B

    更新日期:2013-10-01 00:00:00

  • Spatiotemporally resolved black carbon concentration, schoolchildren's exposure and dose in Barcelona.

    abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12214

    authors: Rivas I,Donaire-Gonzalez D,Bouso L,Esnaola M,Pandolfi M,de Castro M,Viana M,Àlvarez-Pedrerol M,Nieuwenhuijsen M,Alastuey A,Sunyer J,Querol X

    更新日期:2016-06-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Variations of formaldehyde and VOC levels during 3 years in new and older homes.

    abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00408.x

    authors: Park JS,Ikeda K

    更新日期:2006-04-01 00:00:00