Quantitative measurement of airborne cockroach allergen in New York City apartments.

Abstract:

UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child who was allergic to cockroach allergen resided. Four simultaneous air samples were collected in each home: at heights of 0.3 and 1 m in the child's bedroom and in the kitchen. Extracts of air samples were analyzed by ELISA for the cockroach allergen Bla g2, modified by amplifying the colorimetric signal generated via use of AMPLI-Q detection system (DAKO Corporation, Carpinteria, CA, USA). Settled dust samples were quantified by conventional ELISA. Of the homes where cockroach allergen was detected in settled dust, Bla g2 also was detected in 87% and 93% of air samples in the bedroom and kitchen, respectively. Airborne Bla g2 levels were highly correlated within and between the bedroom and kitchen locations (P < 0.001). Expressed as picogram per cubic meter, the room average geometric mean for Bla g2 concentrations was 1.9 pg/m³ (95% CI 0.63, 4.57) and 3.8 pg/m³ (95% CI 1.35, 9.25) in bedrooms and kitchens, respectively. This method offers an attractive supplement to settled dust sampling for cockroach allergen exposure health studies. PRACTICAL IMPLICATIONS:Until now, cockroach allergen exposures have usually been assessed by collection and analysis of settled dust, on the assumption that airborne cockroach allergen cannot be reliably measured. In this study, a sensitive and quantitative method for measuring indoor airborne exposures to cockroach allergens involving a 7-day integrated total suspended particulate (TSP) sample collected at approximately 10-15 l/min was developed. Investigators are now empowered with an alternative exposure assessment method to supplement their studies and the understanding of allergen aerodynamics in the homes of children with asthma. We report airborne cockroach allergen in apartments, suggesting an ongoing burden of inhalation exposure.

journal_name

Indoor Air

journal_title

Indoor air

authors

Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

doi

10.1111/j.1600-0668.2011.00728.x

subject

Has Abstract

pub_date

2011-12-01 00:00:00

pages

512-20

issue

6

eissn

0905-6947

issn

1600-0668

journal_volume

21

pub_type

杂志文章
  • Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study.

    abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00531.x

    authors: Mendell MJ,Lei-Gomez Q,Mirer AG,Seppänen O,Brunner G

    更新日期:2008-08-01 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00

  • Indoor visible mold and mold odor are associated with new-onset childhood wheeze in a dose-dependent manner.

    abstract::Evidence is accumulating that indoor dampness and mold are associated with the development of asthma. The underlying mechanisms remain unknown. New Zealand has high rates of both asthma and indoor mold and is ideally placed to investigate this. We conducted an incident case-control study involving 150 children with ne...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12413

    authors: Shorter C,Crane J,Pierse N,Barnes P,Kang J,Wickens K,Douwes J,Stanley T,Täubel M,Hyvärinen A,Howden-Chapman P,Wellington Region General Practitioner Research Network.

    更新日期:2018-01-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia.

    abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00533.x

    authors: Dionisio KL,Howie S,Fornace KM,Chimah O,Adegbola RA,Ezzati M

    更新日期:2008-08-01 00:00:00

  • Impact of constructional energy-saving measures on radon levels indoors.

    abstract::Energy-efficient building refurbishment has the aim of saving energy and thus reducing CO2 emissions. Increased energy efficiency of a building often implies reduced air exchange. Together with other indoor air quality problems, this may lead to an increase in indoor radon concentration (Rn-222). In order to investiga...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12553

    authors: Meyer W

    更新日期:2019-07-01 00:00:00

  • Collection efficiency of liquid-based samplers for fungi in indoor air.

    abstract::This study assessed the collection efficiency (CE) of two popularly used sampling devices (BioSampler and Coriolis sampler) for fungal aerosols. Phosphate-buffered saline (PBS) supplemented with or without surfactant (Tween-20, Tween-80, or Triton X-100) and antifoam agent was prepared and used as collection liquids. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12535

    authors: Chang CW,Ting YT,Horng YJ

    更新日期:2019-05-01 00:00:00

  • Dampness at dorm and its associations with allergy and airways infection among college students in China: a cross-sectional study.

    abstract:UNLABELLED:A cross-sectional study was carried out at Tianjin University campus, China, from February 21 to June10, 2006, to survey the association between dampness in dorms and allergy and airways infection among college students. The health and dampness condition were self-reported by 3436 students living in 1511 dor...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00577.x

    authors: Sun Y,Zhang Y,Sundell J,Fan Z,Bao L

    更新日期:2009-04-01 00:00:00

  • Co-occupant's exposure to exhaled pollutants with two types of personalized ventilation strategies under mixing and displacement ventilation systems.

    abstract::Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of P...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12005

    authors: Li X,Niu J,Gao N

    更新日期:2013-04-01 00:00:00

  • Ultrafine particles from electric appliances and cooking pans: experiments suggesting desorption/nucleation of sorbed organics as the primary source.

    abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12163

    authors: Wallace LA,Ott WR,Weschler CJ

    更新日期:2015-10-01 00:00:00

  • Determination of radon exhalation from construction materials using VOC emission test chambers.

    abstract::The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available me...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12031

    authors: Richter M,Jann O,Kemski J,Schneider U,Krocker C,Hoffmann B

    更新日期:2013-10-01 00:00:00

  • Biomass fuel smoke exposure was associated with adverse cardiac remodeling and left ventricular dysfunction in Peru.

    abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12362

    authors: Burroughs Peña MS,Velazquez EJ,Rivera JD,Alenezi F,Wong C,Grigsby M,Davila-Roman VG,Gilman RH,Miranda JJ,Checkley W

    更新日期:2017-07-01 00:00:00

  • Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets.

    abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12177

    authors: Licina D,Melikov A,Pantelic J,Sekhar C,Tham KW

    更新日期:2015-12-01 00:00:00

  • Stability of airborne microbes in the Louvre Museum over time.

    abstract::The microbial content of air has as yet been little described, despite its public health implications, and there remains a lack of environmental microbial data on airborne microflora in enclosed spaces. In this context, the aim of this study was to characterize the diversity and dynamics of airborne microorganisms in ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12053

    authors: Gaüzère C,Moletta-Denat M,Blanquart H,Ferreira S,Moularat S,Godon JJ,Robine E

    更新日期:2014-02-01 00:00:00

  • Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena.

    abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00316.x

    authors: Ataka Y,Kato S,Murakami S,Zhu Q,Ito K,Yokota T

    更新日期:2004-01-01 00:00:00

  • Prevalence and risk factors associated with nonspecific building-related symptoms in office employees in Japan: relationships between work environment, Indoor Air Quality, and occupational stress.

    abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12158

    authors: Azuma K,Ikeda K,Kagi N,Yanagi U,Osawa H

    更新日期:2015-10-01 00:00:00

  • Comparison of disinfection performance of UVC-LED and conventional upper-room UVGI systems.

    abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12619

    authors: Nunayon SS,Zhang H,Lai ACK

    更新日期:2020-01-01 00:00:00

  • Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12127

    authors: Yang J,Sekhar SC,Cheong KW,Raphael B

    更新日期:2015-04-01 00:00:00

  • Olfactory detection of ozone and D-limonene: reactants in indoor spaces.

    abstract:UNLABELLED:Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00476.x

    authors: Cain WS,Schmidt R,Wolkoff P

    更新日期:2007-10-01 00:00:00

  • Assessment through environmental and biological measurements of total daily exposure to volatile organic compounds of office workers in Milan, Italy.

    abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010004258.x

    authors: Carrer P,Maroni M,Alcini D,Cavallo D,Fustinoni S,Lovato L,Visigalli F

    更新日期:2000-12-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Chemistry in indoor environments: 20 years of research.

    abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2011.00713.x

    authors: Weschler CJ

    更新日期:2011-06-01 00:00:00

  • Characterization of particulate emissions from occupant activities in offices.

    abstract::This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mas...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011001035.x

    authors: Luoma M,Batterman SA

    更新日期:2001-03-01 00:00:00

  • A review of ventilation and the quality of ventilation air.

    abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0668.2000.010003193.x

    authors: Liddament MW

    更新日期:2000-09-01 00:00:00

  • A pilot study to investigate the effects of combined dehumidification and HEPA filtration on dew point and airborne mold spore counts in day care centers.

    abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00379.x

    authors: Bernstein JA,Levin L,Crandall MS,Perez A,Lanphear B

    更新日期:2005-12-01 00:00:00

  • Does e-cigarette consumption cause passive vaping?

    abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00792.x

    authors: Schripp T,Markewitz D,Uhde E,Salthammer T

    更新日期:2013-02-01 00:00:00

  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Classrooms' indoor environmental conditions affecting the academic achievement of students and teachers in higher education: A systematic literature review.

    abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12745

    authors: Brink HW,Loomans MGLC,Mobach MP,Kort HSM

    更新日期:2020-09-24 00:00:00

  • Particle size distributions and concentrations of airborne endotoxin using novel collection methods in homes during the winter and summer seasons.

    abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00419.x

    authors: Kujundzic E,Hernandez M,Miller SL