Abstract:
UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regarding 'indoor chemistry', much of which came from corrosion and art conservation studies. It then outlines what we have learned in the period between 1991 and 2010 in the context of the major reference categories: gas-phase chemistry, surface chemistry, health effects and reviews/workshops. The indoor reactions that have received the greatest attention are those involving ozone-with terpenoids in the gas-phase as well as with the surfaces of common materials, furnishings, and the occupants themselves. It has become clear that surface reactions often have a larger impact on indoor settings than do gas-phase processes. This review concludes with a subjective list of major research needs going forward, including more information on the decomposition of common indoor pollutants, better understanding of how sorbed water influences surface reactions, and further identification of short-lived products of indoor chemistry. Arguably, the greatest need is for increased knowledge regarding the impact that indoor chemistry has on the health and comfort of building occupants. PRACTICAL IMPLICATIONS:Indoor chemistry changes the type and concentration of chemicals present in indoor environments. In the past, products of indoor chemistry were often overlooked, reflecting a focus on stable, relatively non-polar organic compounds coupled with the use of sampling and analytical methods that were unable to 'see' many of the products of such chemistry. Today, researchers who study indoor environments are more aware of the potential for chemistry to occur. Awareness is valuable, because it leads to the use of sampling methods and analytical tools that can detect changes in indoor environments resulting from chemical processes. This, in turn, leads to a more complete understanding of occupants' chemical exposures, potential links between these exposures and adverse health effects and, finally, steps that might be taken to mitigate these adverse effects.
journal_name
Indoor Airjournal_title
Indoor airauthors
Weschler CJdoi
10.1111/j.1600-0668.2011.00713.xsubject
Has Abstractpub_date
2011-06-01 00:00:00pages
205-18issue
3eissn
0905-6947issn
1600-0668journal_volume
21pub_type
杂志文章,评审相关文献
INDOOR AIR文献大全abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00168.x
更新日期:2004-06-01 00:00:00
abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12536
更新日期:2019-05-01 00:00:00
abstract::We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity,...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12226
更新日期:2016-06-01 00:00:00
abstract::Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside natur...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12057
更新日期:2014-04-01 00:00:00
abstract::Concentrations and emission rates of sixteen trace elements in emitted PM during heating soybean oil using three types of pans, including Teflon, granitium, and cast-iron, were investigated. Statistically significant decreases in Mn and Co emission rates were observed when the oil was heated in the cast-iron pan compa...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12641
更新日期:2020-05-01 00:00:00
abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1034/j.1600-0668.2000.010003193.x
更新日期:2000-09-01 00:00:00
abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00383.x
更新日期:2005-10-01 00:00:00
abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00738.x
更新日期:2012-02-01 00:00:00
abstract:UNLABELLED:Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon mon...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00311.x
更新日期:2005-04-01 00:00:00
abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12520
更新日期:2019-03-01 00:00:00
abstract:UNLABELLED:Previous studies have found inconsistent results on the association between asthma in children and gas cooking emissions. We aimed to assess the effects of the long-term exposure to gas cooking on the onset of asthma and respiratory symptoms, focusing on wheezing, in children from two German birth cohorts: L...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2012.00784.x
更新日期:2012-12-01 00:00:00
abstract::Field measurements were collected through physical measurements and observations in the cities of Seoul, Korea; Eugene and Portland, Oregon; and Yokohama, Japan, during the fall, winter, and summer seasons from 2005 to 2006. A total of 1733 data sets were collected (Seoul - 713; Oregon - 807; Yokohama - 213) in variet...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2010.00705.x
更新日期:2011-08-01 00:00:00
abstract::Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2003.00205.x
更新日期:2003-12-01 00:00:00
abstract::The indoor environmental quality in classrooms can largely affect children's daily exposure to indoor chemicals in schools. To date, there has not been a comprehensive study of the concentrations of semivolatile organic compounds (SVOCs) in French schools. Therefore, the French Observatory for Indoor Air Quality (OQAI...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12724
更新日期:2021-01-01 00:00:00
abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...
journal_title:Indoor air
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1600-0668.2004.00252.x
更新日期:2004-12-01 00:00:00
abstract:UNLABELLED:Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from in...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00364.x
更新日期:2005-08-01 00:00:00
abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00248.x
更新日期:2004-10-01 00:00:00
abstract::A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with al...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.1999.t01-3-00002.x
更新日期:1999-03-01 00:00:00
abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00243.x
更新日期:2004-08-01 00:00:00
abstract::Dampness affects a substantial percentage of homes and is associated with increased risk of respiratory ailments; yet, the effects of dampness on indoor chemistry are largely unknown. We hypothesize that the presence of water-soluble gases and their aqueous processing alters the chemical composition of indoor air and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12422
更新日期:2018-01-01 00:00:00
abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2004.00271.x
更新日期:2004-01-01 00:00:00
abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12163
更新日期:2015-10-01 00:00:00
abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00253.x
更新日期:2004-06-01 00:00:00
abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12622
更新日期:2020-03-01 00:00:00
abstract::Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEP...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12716
更新日期:2021-01-01 00:00:00
abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00356.x
更新日期:2005-01-01 00:00:00
abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...
journal_title:Indoor air
pub_type: 杂志文章,多中心研究
doi:10.1111/ina.12408
更新日期:2018-01-01 00:00:00
abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12701
更新日期:2020-11-01 00:00:00
abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2007.00512.x
更新日期:2008-04-01 00:00:00
abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2003.00183.x
更新日期:2003-09-01 00:00:00