Abstract:
UNLABELLED:Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detection, at about 15-20 ppb. Individual differences in sensitivity lay at or just below an order of magnitude, rare in olfactory testing and indicative of precision. In a study of d-limonene, subjects again showed high sensitivity and small individual differences. The subjects could detect the odor at 8 and 15 ppb, depending upon whether they occupied a space with or without carbon filtration, respectively. The results argue for use of carbon filtration to measure sensitivity most stringently, although absence of filtration seems not to incur a large penalty. The protocol used here, with collection of hundreds of judgments in a day, yet with little net exposure of the subject to odorant; with verifiably stable delivery; and with analytical confirmation of level should reduce tolerance for outcomes of large differences among subjects and among studies. PRACTICAL IMPLICATIONS:Humans manifested much higher sensitivity to ozone and D-limonene than commonly thought, a pattern revealing itself more broadly in olfactory studies as testing improves and analytical confirmation of delivery becomes more common. Published databases, with errors of +/-1000%, often badly underestimate sensitivity and can thereby encourage use of higher concentrations of compounds, particularly VOCs, than relevant in studies of reactive indoor chemistry.
journal_name
Indoor Airjournal_title
Indoor airauthors
Cain WS,Schmidt R,Wolkoff Pdoi
10.1111/j.1600-0668.2007.00476.xsubject
Has Abstractpub_date
2007-10-01 00:00:00pages
337-47issue
5eissn
0905-6947issn
1600-0668pii
INA476journal_volume
17pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12449
更新日期:2018-05-01 00:00:00
abstract:UNLABELLED: Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00757.x
更新日期:2012-06-01 00:00:00
abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00754.x
更新日期:2012-04-01 00:00:00
abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00728.x
更新日期:2011-12-01 00:00:00
abstract:UNLABELLED:Quasi-ultrafine (quasi-UF) particulate matter (PM(0.25)) and its components were measured in indoor and outdoor environments at four retirement communities in Los Angeles Basin, California, as part of the Cardiovascular Health and Air Pollution Study (CHAPS). The present paper focuses on the characterization...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2009.00620.x
更新日期:2010-02-01 00:00:00
abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12536
更新日期:2019-05-01 00:00:00
abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2000.010004258.x
更新日期:2000-12-01 00:00:00
abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...
journal_title:Indoor air
pub_type: 杂志文章,随机对照试验
doi:10.1111/ina.12502
更新日期:2018-11-01 00:00:00
abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00531.x
更新日期:2008-08-01 00:00:00
abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2004.00271.x
更新日期:2004-01-01 00:00:00
abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12163
更新日期:2015-10-01 00:00:00
abstract::Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of P...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12005
更新日期:2013-04-01 00:00:00
abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12220
更新日期:2016-06-01 00:00:00
abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00316.x
更新日期:2004-01-01 00:00:00
abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...
journal_title:Indoor air
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1600-0668.2004.00252.x
更新日期:2004-12-01 00:00:00
abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2006.00432.x
更新日期:2006-10-01 00:00:00
abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12177
更新日期:2015-12-01 00:00:00
abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12158
更新日期:2015-10-01 00:00:00
abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12017
更新日期:2013-06-01 00:00:00
abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12451
更新日期:2018-05-01 00:00:00
abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12619
更新日期:2020-01-01 00:00:00
abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00248.x
更新日期:2004-10-01 00:00:00
abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00738.x
更新日期:2012-02-01 00:00:00
abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12310
更新日期:2017-03-01 00:00:00
abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...
journal_title:Indoor air
pub_type: 杂志文章,多中心研究
doi:10.1111/ina.12408
更新日期:2018-01-01 00:00:00
abstract:UNLABELLED:This paper reports the abundance in indoor air and dust of eleven organophosphate esters and six phthalate esters. Both groups of these semi-volatile compounds are widely incorporated as additives into plastic materials used in the indoor environment, thus contributing to indoor exposure to industrial chemic...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2010.00684.x
更新日期:2011-02-01 00:00:00
abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2009.00590.x
更新日期:2009-06-01 00:00:00
abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00533.x
更新日期:2008-08-01 00:00:00
abstract:UNLABELLED:Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon mon...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00311.x
更新日期:2005-04-01 00:00:00
abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12520
更新日期:2019-03-01 00:00:00