Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

Abstract:

:Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaners in reducing indoor concentrations of traffic-related and other aerosols, including black carbon (BC), PM2.5 , ultraviolet absorbing particulate matter (UVPM) (a marker of tobacco smoke), and fungal spores. This intervention study consisted of a placebo-controlled cross-over design, in which a HEPA cleaner and a placebo "dummy" were placed in homes for 4-weeks each, with 48-hour air sampling conducted prior to and during the end of each treatment period. The concentrations measured for BC, PM2.5 , UVPM, and fungal spores were significantly reduced following HEPA filtration, but not following the dummy period. The indoor fraction of BC/PM2.5 was significantly reduced due to the HEPA cleaner, indicating that black carbon was particularly impacted by HEPA filtration. This study demonstrates that HEPA air purification can result in a significant reduction of traffic-related and other aerosols in diverse residential settings.

journal_name

Indoor Air

journal_title

Indoor air

authors

Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

doi

10.1111/ina.12502

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

818-827

issue

6

eissn

0905-6947

issn

1600-0668

journal_volume

28

pub_type

杂志文章,随机对照试验
  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Human symptom responses to bioeffluents, short-chain carbonyls/acids, and long-chain carbonyls in a simulated aircraft cabin environment.

    abstract::Occupants of aircraft have reported an array of symptoms related to general discomfort and irritation. Volatile organic compounds (VOCs) have been suggested to contribute to the reported symptoms. VOCs are from products used, bioeffluents from people and oxidation reaction products. Thirty-six healthy, young female su...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12392

    authors: Weisel CP,Fiedler N,Weschler CJ,Ohman-Strickland PA,Mohan KR,McNeil K,Space DR

    更新日期:2017-11-01 00:00:00

  • Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris, France).

    abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12358

    authors: Paunescu AC,Attoui M,Bouallala S,Sunyer J,Momas I

    更新日期:2017-07-01 00:00:00

  • Prevalence and risk factors associated with nonspecific building-related symptoms in office employees in Japan: relationships between work environment, Indoor Air Quality, and occupational stress.

    abstract::A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12158

    authors: Azuma K,Ikeda K,Kagi N,Yanagi U,Osawa H

    更新日期:2015-10-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Simulating the human body's microclimate using automatic coupling of CFD and an advanced thermoregulation model.

    abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12451

    authors: Voelker C,Alsaad H

    更新日期:2018-05-01 00:00:00

  • Stability of airborne microbes in the Louvre Museum over time.

    abstract::The microbial content of air has as yet been little described, despite its public health implications, and there remains a lack of environmental microbial data on airborne microflora in enclosed spaces. In this context, the aim of this study was to characterize the diversity and dynamics of airborne microorganisms in ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12053

    authors: Gaüzère C,Moletta-Denat M,Blanquart H,Ferreira S,Moularat S,Godon JJ,Robine E

    更新日期:2014-02-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Oxygenated VOCs, aqueous chemistry, and potential impacts on residential indoor air composition.

    abstract::Dampness affects a substantial percentage of homes and is associated with increased risk of respiratory ailments; yet, the effects of dampness on indoor chemistry are largely unknown. We hypothesize that the presence of water-soluble gases and their aqueous processing alters the chemical composition of indoor air and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12422

    authors: Duncan SM,Sexton KG,Turpin BJ

    更新日期:2018-01-01 00:00:00

  • Indoor gaseous air pollutants determinants in office buildings-The OFFICAIR project.

    abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12609

    authors: Spinazzè A,Campagnolo D,Cattaneo A,Urso P,Sakellaris IA,Saraga DE,Mandin C,Canha N,Mabilia R,Perreca E,Mihucz VG,Szigeti T,Ventura G,de Oliveira Fernandes E,de Kluizenaar Y,Cornelissen E,Hänninen O,Carrer P,Wolkoff P

    更新日期:2020-01-01 00:00:00

  • Influence of local airflow on the pollutant emission from indoor building surfaces.

    abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011003162.x

    authors: Topp C,Nielsen PV,Heiselberg P

    更新日期:2001-09-01 00:00:00

  • Indoor environmental control of tuberculosis and other airborne infections.

    abstract::Tuberculosis (TB) remains the airborne infection of global importance, although many environmental interventions to control TB apply to influenza and other infections with airborne potential. This review focuses on the global problem and the current state of available environmental interventions. TB transmission is fa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12232

    authors: Nardell EA

    更新日期:2016-02-01 00:00:00

  • Indoor environmental quality in a 'low allergen' school and three standard primary schools in Western Australia.

    abstract::To investigate indoor environmental quality in classrooms, assessments were undertaken in a 'low allergen' school and three standard primary schools in Western Australia. Dust allergens, air pollutants and physical parameters were monitored in the four schools at four times (summer school term, autumn holiday, winter ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00405.x

    authors: Zhang G,Spickett J,Rumchev K,Lee AH,Stick S

    更新日期:2006-02-01 00:00:00

  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

    abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12341

    authors: Chua ML,Setyawati MI,Li H,Fang CHY,Gurusamy S,Teoh FTL,Leong DT,George S

    更新日期:2017-05-01 00:00:00

  • Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system.

    abstract:UNLABELLED:Ventilation performance and pollutant distribution in a traditional ceiling-type ventilation system, a top-return (TR)-type and a floor-return (FR)-type underfloor ventilation systems were performed in a controlled experimental room. Tracer gas method was utilized to determine the age of air and the contamin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00248.x

    authors: Chao CY,Wan MP

    更新日期:2004-10-01 00:00:00

  • Variations of formaldehyde and VOC levels during 3 years in new and older homes.

    abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00408.x

    authors: Park JS,Ikeda K

    更新日期:2006-04-01 00:00:00

  • Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

    abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00243.x

    authors: Finlayson EU,Gadgil AJ,Thatcher TL,Sextro RG

    更新日期:2004-08-01 00:00:00

  • Classrooms' indoor environmental conditions affecting the academic achievement of students and teachers in higher education: A systematic literature review.

    abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12745

    authors: Brink HW,Loomans MGLC,Mobach MP,Kort HSM

    更新日期:2020-09-24 00:00:00

  • Olfactory detection of ozone and D-limonene: reactants in indoor spaces.

    abstract:UNLABELLED:Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00476.x

    authors: Cain WS,Schmidt R,Wolkoff P

    更新日期:2007-10-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Experimental validation of a computational fluid dynamics model for IAQ applications in ice rink arenas.

    abstract::Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acc...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.110206.x

    authors: Yang C,Demokritou P,Chen Q,Spengler J

    更新日期:2001-06-01 00:00:00

  • Semivolatile organic compounds in French schools: Partitioning between the gas phase, airborne particles and settled dust.

    abstract::The indoor environmental quality in classrooms can largely affect children's daily exposure to indoor chemicals in schools. To date, there has not been a comprehensive study of the concentrations of semivolatile organic compounds (SVOCs) in French schools. Therefore, the French Observatory for Indoor Air Quality (OQAI...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12724

    authors: Wei W,Dassonville C,Sivanantham S,Gregoire A,Mercier F,Le Bot B,Malingre L,Ramalho O,Derbez M,Mandin C

    更新日期:2021-01-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Investigating measurements of fine particle (PM2.5 ) emissions from the cooking of meals and mitigating exposure using a cooker hood.

    abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12542

    authors: O'Leary C,de Kluizenaar Y,Jacobs P,Borsboom W,Hall I,Jones B

    更新日期:2019-05-01 00:00:00

  • A new exposure route to trace elements in indoor particulate matter.

    abstract::Concentrations and emission rates of sixteen trace elements in emitted PM during heating soybean oil using three types of pans, including Teflon, granitium, and cast-iron, were investigated. Statistically significant decreases in Mn and Co emission rates were observed when the oil was heated in the cast-iron pan compa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12641

    authors: Broomandi P,Amouei Torkmahalleh M,Akturk M,Ngagine SH,Gorjinezhad S,Ozturk F,Kocak M,Kim J

    更新日期:2020-05-01 00:00:00

  • Determination of formaldehyde emission with field and laboratory emission cell (FLEC)--recovery and correlation to the chamber method.

    abstract::The formaldehyde emission from wood-based building materials is usually determined in large chambers at a defined temperature, humidity and ventilation rate. In this article, a simpler method, the Field and Laboratory Emission Cell (FLEC), is described for determination of the formaldehyde emission and it is compared ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.1999.00006.x

    authors: Risholm-Sundman M

    更新日期:1999-12-01 00:00:00

  • A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach.

    abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00426.x

    authors: Chao CY,Wan MP

    更新日期:2006-08-01 00:00:00

  • Use of a robotic sampling platform to assess young children's exposure to indoor bioaerosols.

    abstract:UNLABELLED:Indoor exposures to allergens, mold spores, and endotoxin have been suggested as etiological agents of asthma; therefore, accurate determination of those exposures, especially in young children (6-36 months), is important for understanding the development of asthma. Because use of personal sampling equipment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00749.x

    authors: Wang Z,Shalat SL,Black K,Lioy PJ,Stambler AA,Emoekpere OH,Hernandez M,Han T,Ramagopal M,Mainelis G

    更新日期:2012-04-01 00:00:00