A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

Abstract:

UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because of the complexity of air diffuser geometry and the complicated airflow pattern generated. Typical air diffusers used for displacement ventilation systems include, but are not limited to, quarter-circular-perforated, grille, floor-perforated, and swirl diffusers. None of them can be treated as a simple opening in CFD simulations because their effective area ratios are small. We have developed a new, simple method to describe those diffusers by directly specifying the correct jet momentum from the diffusers while adjusting the airflow rate by changing the effective areas. This is done by setting some CFD cells for a diffuser with a certain momentum, while other cells are randomly blocked. By implementing this method into a commercial CFD program, this study used the method to simulate air distributions in an office and a workshop with those diffusers under cooling or heating conditions. The distributions of air velocity, temperature, and airborne contaminant concentration are in good agreement with the corresponding experimental data obtained from an environmental chamber. PRACTICAL IMPLICATIONS:This paper presents a simplified method for description of complex diffusers in computational fluid dynamics simulation of displacement ventilation at high computational efficiency. It may be used to assist the design and analysis of air distribution for displacement ventilation as well as other types of ventilation with complex diffusers.

journal_name

Indoor Air

journal_title

Indoor air

authors

Zhang TT,Lee K,Chen QY

doi

10.1111/j.1600-0668.2009.00590.x

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

255-67

issue

3

eissn

0905-6947

issn

1600-0668

pii

INA590

journal_volume

19

pub_type

杂志文章
  • Variations of formaldehyde and VOC levels during 3 years in new and older homes.

    abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00408.x

    authors: Park JS,Ikeda K

    更新日期:2006-04-01 00:00:00

  • Machine learning and statistical models for predicting indoor air quality.

    abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12580

    authors: Wei W,Ramalho O,Malingre L,Sivanantham S,Little JC,Mandin C

    更新日期:2019-09-01 00:00:00

  • Determinants, reproducibility, and seasonal variation of bacterial cell wall components and viable counts in house dust.

    abstract::The objectives of this study were (i) to assess the determinants that affect concentrations of the bacterial cell wall components 3-hydroxy fatty acids (3-OH FAs) and muramic acid and of total viable bacteria and actinomycetes in house dust; and (ii) to examine the seasonal variation and reproducibility of these bacte...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12141

    authors: Leppänen HK,Täubel M,Roponen M,Vepsäläinen A,Rantakokko P,Pekkanen J,Nevalainen A,von Mutius E,Hyvärinen A

    更新日期:2015-06-01 00:00:00

  • Airborne particle emission of a commercial 3D printer: the effect of filament material and printing temperature.

    abstract::The knowledge of exposure to the airborne particle emitted from three-dimensional (3D) printing activities is becoming a crucial issue due to the relevant spreading of such devices in recent years. To this end, a low-cost desktop 3D printer based on fused deposition modeling (FDM) principle was used. Particle number, ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12310

    authors: Stabile L,Scungio M,Buonanno G,Arpino F,Ficco G

    更新日期:2017-03-01 00:00:00

  • Biomass fuel smoke exposure was associated with adverse cardiac remodeling and left ventricular dysfunction in Peru.

    abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12362

    authors: Burroughs Peña MS,Velazquez EJ,Rivera JD,Alenezi F,Wong C,Grigsby M,Davila-Roman VG,Gilman RH,Miranda JJ,Checkley W

    更新日期:2017-07-01 00:00:00

  • A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach.

    abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00426.x

    authors: Chao CY,Wan MP

    更新日期:2006-08-01 00:00:00

  • Comparison of two dust collection methods for reservoir indoor allergens and endotoxin on carpets and mattresses.

    abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00253.x

    authors: Wickens K,Lane J,Siebers R,Ingham T,Crane J

    更新日期:2004-06-01 00:00:00

  • Endotoxin, extracellular polysaccharides, and β(1-3)-glucan concentrations in dust and their determinants in four European birth cohorts: results from the HITEA project.

    abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12017

    authors: Casas L,Tischer C,Wouters IM,Valkonen M,Gehring U,Doekes G,Torrent M,Pekkanen J,Garcia-Esteban R,Hyvärinen A,Heinrich J,Sunyer J

    更新日期:2013-06-01 00:00:00

  • Single-particle characterization of indoor aerosol particles collected at an underground shopping area in Seoul, Korea.

    abstract:UNLABELLED:In this study, single-particle characterization of aerosol particles collected at an underground shopping area was performed for the first time. A quantitative single-particle analytical technique, low-Z particle electron probe X-ray microanalysis, was used to characterize a total of 7900 individual particle...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00677.x

    authors: Maskey S,Kang T,Jung HJ,Ro CU

    更新日期:2011-02-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

    abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12341

    authors: Chua ML,Setyawati MI,Li H,Fang CHY,Gurusamy S,Teoh FTL,Leong DT,George S

    更新日期:2017-05-01 00:00:00

  • Organic compound characterization and source apportionment of indoor and outdoor quasi-ultrafine particulate matter in retirement homes of the Los Angeles Basin.

    abstract:UNLABELLED:Quasi-ultrafine (quasi-UF) particulate matter (PM(0.25)) and its components were measured in indoor and outdoor environments at four retirement communities in Los Angeles Basin, California, as part of the Cardiovascular Health and Air Pollution Study (CHAPS). The present paper focuses on the characterization...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00620.x

    authors: Arhami M,Minguillón MC,Polidori A,Schauer JJ,Delfino RJ,Sioutas C

    更新日期:2010-02-01 00:00:00

  • Assessment through environmental and biological measurements of total daily exposure to volatile organic compounds of office workers in Milan, Italy.

    abstract::Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010004258.x

    authors: Carrer P,Maroni M,Alcini D,Cavallo D,Fustinoni S,Lovato L,Visigalli F

    更新日期:2000-12-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Droplet fate in indoor environments, or can we prevent the spread of infection?

    abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2006.00432.x

    authors: Morawska L

    更新日期:2006-10-01 00:00:00

  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Exposure to ultrafine particles in children until 18 years of age: A systematic review.

    abstract::Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12620

    authors: García-Hernández C,Ferrero A,Estarlich M,Ballester F

    更新日期:2020-01-01 00:00:00

  • Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study.

    abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00531.x

    authors: Mendell MJ,Lei-Gomez Q,Mirer AG,Seppänen O,Brunner G

    更新日期:2008-08-01 00:00:00

  • Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions.

    abstract:UNLABELLED:Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00512.x

    authors: Huang R,Agranovski I,Pyankov O,Grinshpun S

    更新日期:2008-04-01 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00

  • Particle dose estimation from frying in residential settings.

    abstract:UNLABELLED:Fumes produced during frying have been implicated as a potential cause for the increased incidence of adenocarcinoma. Particulate matter exposure has also been linked with other pulmonary and coronary disease. This study investigated the contribution of frying in residential settings to ultrafine and fine pa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00551.x

    authors: Evans GJ,Peers A,Sabaliauskas K

    更新日期:2008-12-01 00:00:00

  • Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation.

    abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00383.x

    authors: He G,Yang X,Srebric J

    更新日期:2005-10-01 00:00:00

  • Assessment of human exposure to indoor organic contaminants via dust ingestion in Pakistan.

    abstract:UNLABELLED:  Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00757.x

    authors: Ali N,Van den Eede N,Dirtu AC,Neels H,Covaci A

    更新日期:2012-06-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Influence of local airflow on the pollutant emission from indoor building surfaces.

    abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011003162.x

    authors: Topp C,Nielsen PV,Heiselberg P

    更新日期:2001-09-01 00:00:00

  • Assessment of indoor HONO formation mechanisms based on in situ measurements and modeling.

    abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12320

    authors: Mendez M,Blond N,Amedro D,Hauglustaine DA,Blondeau P,Afif C,Fittschen C,Schoemaecker C

    更新日期:2017-03-01 00:00:00

  • Productivity and fatigue.

    abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00281.x

    authors: Tanabe S,Nishihara N

    更新日期:2004-01-01 00:00:00

  • Does e-cigarette consumption cause passive vaping?

    abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00792.x

    authors: Schripp T,Markewitz D,Uhde E,Salthammer T

    更新日期:2013-02-01 00:00:00

  • Indoor air pollution in developing countries: recommendations for research.

    abstract::Available studies indicate that indoor air pollution (IAP) from household cooking and space heating apparently causes substantial ill-health in developing countries where the majority of households rely on solid fuels (coal or biomass as wood, crop residues, and dung), but there are many remaining uncertainties. To pi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01137.x

    authors: Smith KR

    更新日期:2002-09-01 00:00:00