Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation.

Abstract:

UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is designed and constructed. Two different types of ventilation are studied: displacement and mixing ventilation. A computer model for predicting the contaminant dispersion in indoor spaces was validated with experimental data. The validated model is used to study the effects of airflow and the area-source location on contaminant dispersion. Results show that the global airflow pattern has a strong impact on the distribution of the contaminants. In general, the personal exposure could be estimated by analyzing the relative source positions in the airflow pattern. Accordingly, the location of an exhaust diffuser may not greatly affect the airflow pattern, but can significantly affect the exposure level in the room. PRACTICAL IMPLICATIONS:When designing ventilation in addition to bringing fresh air to occupants, it is important to consider the removal of contaminants released in the off-gassing of building materials. Typical indoor off-gassing examples are emissions of volatile organic compounds from building enclosure surfaces such as flooring and painted walls. In this study, we conducted experimental and numerical modeling of different area sources in a mock-up office setup, with displacement or mixing ventilation. Displacement ventilation was as successful as mixing ventilation in removing the contaminant source from the floor area. Actually, the most important consideration in the removal of these contaminants is the relative position of the area source to the main airflow pattern and the occupied zone.

journal_name

Indoor Air

journal_title

Indoor air

authors

He G,Yang X,Srebric J

doi

10.1111/j.1600-0668.2005.00383.x

subject

Has Abstract

pub_date

2005-10-01 00:00:00

pages

367-80

issue

5

eissn

0905-6947

issn

1600-0668

pii

INA383

journal_volume

15

pub_type

杂志文章
  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Indoor air pollution in developing countries: recommendations for research.

    abstract::Available studies indicate that indoor air pollution (IAP) from household cooking and space heating apparently causes substantial ill-health in developing countries where the majority of households rely on solid fuels (coal or biomass as wood, crop residues, and dung), but there are many remaining uncertainties. To pi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01137.x

    authors: Smith KR

    更新日期:2002-09-01 00:00:00

  • Indoor environmental quality in a 'low allergen' school and three standard primary schools in Western Australia.

    abstract::To investigate indoor environmental quality in classrooms, assessments were undertaken in a 'low allergen' school and three standard primary schools in Western Australia. Dust allergens, air pollutants and physical parameters were monitored in the four schools at four times (summer school term, autumn holiday, winter ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00405.x

    authors: Zhang G,Spickett J,Rumchev K,Lee AH,Stick S

    更新日期:2006-02-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • Quantitative measurement of airborne cockroach allergen in New York City apartments.

    abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00728.x

    authors: Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

    更新日期:2011-12-01 00:00:00

  • Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes.

    abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12220

    authors: Aldred JR,Darling E,Morrison G,Siegel J,Corsi RL

    更新日期:2016-06-01 00:00:00

  • Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces.

    abstract::A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with al...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.1999.t01-3-00002.x

    authors: Jørgensen RB,Bjørseth O,Malvik B

    更新日期:1999-03-01 00:00:00

  • Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US.

    abstract::Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building vent...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12743

    authors: Myers NT,Calderón L,Pavilonis B,Wang Z,Xiong Y,Sorensen-Allacci M,Plotnik D,Senick J,Gong J,Krogmann U,Andrews CJ,Mainelis G

    更新日期:2020-09-15 00:00:00

  • Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

    abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00183.x

    authors: Sohn MD,Sextro RG,Gadgil AJ,Daisey JM

    更新日期:2003-09-01 00:00:00

  • Quantitative aerobiologic analysis of an influenza human challenge-transmission trial.

    abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12701

    authors: Bueno de Mesquita PJ,Noakes CJ,Milton DK

    更新日期:2020-11-01 00:00:00

  • Air movement--good or bad?

    abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2004.00271.x

    authors: Toftum J

    更新日期:2004-01-01 00:00:00

  • Hygroscopic fine mode particle deposition on electronic circuits and resulting degradation of circuit performance: an experimental study.

    abstract::A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010001047.x

    authors: Litvak A,Gadgil AJ,Fisk WJ

    更新日期:2000-03-01 00:00:00

  • Measuring the exposure of infants and children to indoor air pollution from biomass fuels in The Gambia.

    abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00533.x

    authors: Dionisio KL,Howie S,Fornace KM,Chimah O,Adegbola RA,Ezzati M

    更新日期:2008-08-01 00:00:00

  • Chemistry in indoor environments: 20 years of research.

    abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2011.00713.x

    authors: Weschler CJ

    更新日期:2011-06-01 00:00:00

  • A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

    abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00590.x

    authors: Zhang TT,Lee K,Chen QY

    更新日期:2009-06-01 00:00:00

  • Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.

    abstract::Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEP...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12716

    authors: Barkjohn KK,Norris C,Cui X,Fang L,Zheng T,Schauer JJ,Li Z,Zhang Y,Black M,Zhang JJ,Bergin MH

    更新日期:2021-01-01 00:00:00

  • Olfactory detection of ozone and D-limonene: reactants in indoor spaces.

    abstract:UNLABELLED:Young adult subjects who occupied a well-ventilated space with low background of level of ozone achieved via carbon-filtration could detect ozone odor at 7 ppb, lower than expected from archival compilations. The outcome was not inconsistent, however, with some observations of recognition, beyond mere detect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00476.x

    authors: Cain WS,Schmidt R,Wolkoff P

    更新日期:2007-10-01 00:00:00

  • Does e-cigarette consumption cause passive vaping?

    abstract:UNLABELLED:Electronic cigarette consumption ('vaping') is marketed as an alternative to conventional tobacco smoking. Technically, a mixture of chemicals containing carrier liquids, flavors, and optionally nicotine is vaporized and inhaled. The present study aims at the determination of the release of volatile organic ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2012.00792.x

    authors: Schripp T,Markewitz D,Uhde E,Salthammer T

    更新日期:2013-02-01 00:00:00

  • Impact of constructional energy-saving measures on radon levels indoors.

    abstract::Energy-efficient building refurbishment has the aim of saving energy and thus reducing CO2 emissions. Increased energy efficiency of a building often implies reduced air exchange. Together with other indoor air quality problems, this may lead to an increase in indoor radon concentration (Rn-222). In order to investiga...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12553

    authors: Meyer W

    更新日期:2019-07-01 00:00:00

  • Ultrafine, fine, and black carbon particle concentrations in California child-care facilities.

    abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...

    journal_title:Indoor air

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ina.12408

    authors: Gaspar FW,Maddalena R,Williams J,Castorina R,Wang ZM,Kumagai K,McKone TE,Bradman A

    更新日期:2018-01-01 00:00:00

  • Risk assessment of formaldehyde in typical office buildings in Taiwan.

    abstract::Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2003.00205.x

    authors: Wu PC,Li YY,Lee CC,Chiang CM,Su HJ

    更新日期:2003-12-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • Comparison of risk factor profiles concerning self-reported skin complaints and objectively determined skin symptoms in German office workers.

    abstract::The correspondence between impact factor profiles of self-reported skin sensation and of objectively determined skin symptoms was examined using data from the ProKlimA project (1994-1999). A sub-sample of 925 office workers participated in measurements of skin hydration and sebum content and responded to a questionnai...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1046/j.1600-0668.2003.00222.x

    authors: Brasche S,Bullinger M,Schwab R,Gebhardt H,Herzog V,Bischof W

    更新日期:2004-04-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Determinants, reproducibility, and seasonal variation of bacterial cell wall components and viable counts in house dust.

    abstract::The objectives of this study were (i) to assess the determinants that affect concentrations of the bacterial cell wall components 3-hydroxy fatty acids (3-OH FAs) and muramic acid and of total viable bacteria and actinomycetes in house dust; and (ii) to examine the seasonal variation and reproducibility of these bacte...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12141

    authors: Leppänen HK,Täubel M,Roponen M,Vepsäläinen A,Rantakokko P,Pekkanen J,Nevalainen A,von Mutius E,Hyvärinen A

    更新日期:2015-06-01 00:00:00

  • The relationship between measured moisture conditions and fungal concentrations in water-damaged building materials.

    abstract::We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010002111.x

    authors: Pasanen AL,Rautiala S,Kasanen JP,Raunio P,Rantamäki J,Kalliokoski P

    更新日期:2000-06-01 00:00:00

  • Oxygenated VOCs, aqueous chemistry, and potential impacts on residential indoor air composition.

    abstract::Dampness affects a substantial percentage of homes and is associated with increased risk of respiratory ailments; yet, the effects of dampness on indoor chemistry are largely unknown. We hypothesize that the presence of water-soluble gases and their aqueous processing alters the chemical composition of indoor air and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12422

    authors: Duncan SM,Sexton KG,Turpin BJ

    更新日期:2018-01-01 00:00:00

  • Early age exposure to moisture damage and systemic inflammation at the age of 6 years.

    abstract::Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12454

    authors: Karvonen AM,Tischer C,Kirjavainen PV,Roponen M,Hyvärinen A,Illi S,Mustonen K,Pfefferle PI,Renz H,Remes S,Schaub B,von Mutius E,Pekkanen J

    更新日期:2018-05-01 00:00:00