Particulate matter from indoor environments of classroom induced higher cytotoxicity and leakiness in human microvascular endothelial cells in comparison with those collected from corridor.

Abstract:

:We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Oxidative stress-dependent cytotoxicity responses were assessed using quantitative reverse transcriptase polymerase chain reaction (RT-PCR) and high content screening (HCS), and disruption of monolayer cell integrity was assessed using fluorescence microscopy and transwell assay. Scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDX) analysis showed differences in the morphology and elemental composition of PM of different sizes and origins. While the total mass of PM collected from indoor environment was lower in comparison with those collected from the corridor, the endotoxin content was substantially higher in indoor PM (e.g., ninefold higher endotoxin level in indoor PM8.1-20 ). The ability to induce oxidative stress-mediated cytotoxicity and leakiness in cell monolayer were higher for indoor PM compared to those collected from the corridor. In conclusion, this comparative analysis suggested that indoor PM is relatively more hazardous to the endothelial system possibly because of higher endotoxin content.

journal_name

Indoor Air

journal_title

Indoor air

authors

Chua ML,Setyawati MI,Li H,Fang CHY,Gurusamy S,Teoh FTL,Leong DT,George S

doi

10.1111/ina.12341

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

551-563

issue

3

eissn

0905-6947

issn

1600-0668

journal_volume

27

pub_type

杂志文章
  • Building-related symptoms and inflammatory potency of dust from office buildings.

    abstract:UNLABELLED:The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00493.x

    authors: Allermann L,Pejtersen J,Gunnarsen L,Poulsen OM

    更新日期:2007-12-01 00:00:00

  • Particle dose estimation from frying in residential settings.

    abstract:UNLABELLED:Fumes produced during frying have been implicated as a potential cause for the increased incidence of adenocarcinoma. Particulate matter exposure has also been linked with other pulmonary and coronary disease. This study investigated the contribution of frying in residential settings to ultrafine and fine pa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00551.x

    authors: Evans GJ,Peers A,Sabaliauskas K

    更新日期:2008-12-01 00:00:00

  • Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris, France).

    abstract::This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9-year-old c...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12358

    authors: Paunescu AC,Attoui M,Bouallala S,Sunyer J,Momas I

    更新日期:2017-07-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Comparison of two dust collection methods for reservoir indoor allergens and endotoxin on carpets and mattresses.

    abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00253.x

    authors: Wickens K,Lane J,Siebers R,Ingham T,Crane J

    更新日期:2004-06-01 00:00:00

  • Benefit-cost analysis of commercially available activated carbon filters for indoor ozone removal in single-family homes.

    abstract::This study involved the development of a model for evaluating the potential costs and benefits of ozone control by activated carbon filtration in single-family homes. The modeling effort included the prediction of indoor ozone with and without activated carbon filtration in the HVAC system. As one application, the mod...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12220

    authors: Aldred JR,Darling E,Morrison G,Siegel J,Corsi RL

    更新日期:2016-06-01 00:00:00

  • Indoor environmental quality in a 'low allergen' school and three standard primary schools in Western Australia.

    abstract::To investigate indoor environmental quality in classrooms, assessments were undertaken in a 'low allergen' school and three standard primary schools in Western Australia. Dust allergens, air pollutants and physical parameters were monitored in the four schools at four times (summer school term, autumn holiday, winter ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00405.x

    authors: Zhang G,Spickett J,Rumchev K,Lee AH,Stick S

    更新日期:2006-02-01 00:00:00

  • A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations.

    abstract:UNLABELLED:With the capability to improve indoor air quality while simultaneously reducing energy demand, displacement ventilation is becoming popular. However, the numerical simulation of air distribution in an indoor space with displacement ventilation using computational fluid dynamics (CFD) is challenging because o...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00590.x

    authors: Zhang TT,Lee K,Chen QY

    更新日期:2009-06-01 00:00:00

  • Comparison of disinfection performance of UVC-LED and conventional upper-room UVGI systems.

    abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12619

    authors: Nunayon SS,Zhang H,Lai ACK

    更新日期:2020-01-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • Influence of local airflow on the pollutant emission from indoor building surfaces.

    abstract::This article reports the results of an investigation, based on fundamental fluid dynamics and mass transfer theory, carried out to obtain a general understanding of the mechanisms involved in the emissions from building materials in ventilated rooms. In addition, a generally applicable method for the prediction of sur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2001.011003162.x

    authors: Topp C,Nielsen PV,Heiselberg P

    更新日期:2001-09-01 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00

  • Chemistry in indoor environments: 20 years of research.

    abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2011.00713.x

    authors: Weschler CJ

    更新日期:2011-06-01 00:00:00

  • Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces.

    abstract:UNLABELLED:Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from in...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00364.x

    authors: Grinshpun SA,Mainelis G,Trunov M,Adhikari A,Reponen T,Willeke K

    更新日期:2005-08-01 00:00:00

  • Co-occupant's exposure to exhaled pollutants with two types of personalized ventilation strategies under mixing and displacement ventilation systems.

    abstract::Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of P...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12005

    authors: Li X,Niu J,Gao N

    更新日期:2013-04-01 00:00:00

  • Polybrominated diphenyl ether (PBDE) concentrations and resulting exposure in homes in California: relationships among passive air, surface wipe and dust concentrations, and temporal variability.

    abstract::Polybrominated diphenyl ethers (PBDEs) are used as flame retardants in furniture foam, electronics, and other home furnishings. A field study was conducted that enrolled 139 households from California, which has had more stringent flame retardant requirements than other countries and areas. The study collected passive...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12130

    authors: Bennett DH,Moran RE,Wu XM,Tulve NS,Clifton MS,Colón M,Weathers W,Sjödin A,Jones R,Hertz-Picciotto I

    更新日期:2015-04-01 00:00:00

  • Indoor thermal stratification and its statistical distribution.

    abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12520

    authors: Wang LL,Zhang X,Qi D

    更新日期:2019-03-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Controlled experiments measuring personal exposure to PM2.5 in close proximity to cigarette smoking.

    abstract::Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside natur...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12057

    authors: Acevedo-Bolton V,Ott WR,Cheng KC,Jiang RT,Klepeis NE,Hildemann LM

    更新日期:2014-04-01 00:00:00

  • Indoor organophosphate and polybrominated flame retardants in Tokyo.

    abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00442.x

    authors: Saito I,Onuki A,Seto H

    更新日期:2007-02-01 00:00:00

  • A pilot study to investigate the effects of combined dehumidification and HEPA filtration on dew point and airborne mold spore counts in day care centers.

    abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00379.x

    authors: Bernstein JA,Levin L,Crandall MS,Perez A,Lanphear B

    更新日期:2005-12-01 00:00:00

  • Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12127

    authors: Yang J,Sekhar SC,Cheong KW,Raphael B

    更新日期:2015-04-01 00:00:00

  • Ultrafine, fine, and black carbon particle concentrations in California child-care facilities.

    abstract::Although many U.S. children spend time in child care, little information exists on exposures to airborne particulate matter (PM) in this environment, even though PM may be associated with asthma and other respiratory illness, which is a key concern for young children. To address this data gap, we measured ultrafine pa...

    journal_title:Indoor air

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ina.12408

    authors: Gaspar FW,Maddalena R,Williams J,Castorina R,Wang ZM,Kumagai K,McKone TE,Bradman A

    更新日期:2018-01-01 00:00:00

  • Determinants, reproducibility, and seasonal variation of bacterial cell wall components and viable counts in house dust.

    abstract::The objectives of this study were (i) to assess the determinants that affect concentrations of the bacterial cell wall components 3-hydroxy fatty acids (3-OH FAs) and muramic acid and of total viable bacteria and actinomycetes in house dust; and (ii) to examine the seasonal variation and reproducibility of these bacte...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12141

    authors: Leppänen HK,Täubel M,Roponen M,Vepsäläinen A,Rantakokko P,Pekkanen J,Nevalainen A,von Mutius E,Hyvärinen A

    更新日期:2015-06-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • Investigating measurements of fine particle (PM2.5 ) emissions from the cooking of meals and mitigating exposure using a cooker hood.

    abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12542

    authors: O'Leary C,de Kluizenaar Y,Jacobs P,Borsboom W,Hall I,Jones B

    更新日期:2019-05-01 00:00:00

  • Subjective perceptions, symptom intensity and performance: a comparison of two independent studies, both changing similarly the pollution load in an office.

    abstract::The present paper shows that introducing or removing the same pollution source in an office in two independent investigations, one in Denmark and one in Sweden, using similar experimental methodology, resulted in similar and repeatable effects on subjective assessments of perceived air quality, intensity of sick build...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.01101.x

    authors: Wargocki P,Lagercrantz L,Witterseh T,Sundell J,Wyon DP,Fanger PO

    更新日期:2002-06-01 00:00:00

  • Indoor environmental control of tuberculosis and other airborne infections.

    abstract::Tuberculosis (TB) remains the airborne infection of global importance, although many environmental interventions to control TB apply to influenza and other infections with airborne potential. This review focuses on the global problem and the current state of available environmental interventions. TB transmission is fa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12232

    authors: Nardell EA

    更新日期:2016-02-01 00:00:00

  • Quantitative filter forensics with residential HVAC filters to assess indoor concentrations.

    abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12536

    authors: Givehchi R,Maestre JP,Bi C,Wylie D,Xu Y,Kinney KA,Siegel JA

    更新日期:2019-05-01 00:00:00

  • Chamber testing of adsorption of volatile organic compounds (VOCs) on material surfaces.

    abstract::A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with al...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.1999.t01-3-00002.x

    authors: Jørgensen RB,Bjørseth O,Malvik B

    更新日期:1999-03-01 00:00:00