Prevalence and risk factors associated with nonspecific building-related symptoms in office employees in Japan: relationships between work environment, Indoor Air Quality, and occupational stress.

Abstract:

:A nationwide cross-sectional study of 3335 employees was conducted in 320 offices in Japan to estimate the prevalence of building-related symptoms (BRSs) and determine the risk factors related to work environment, Indoor Air Quality, and occupational stress. Data were collected through self-administered questionnaires. The prevalences of general symptoms, eye irritation, and upper respiratory symptoms were 14.4%, 12.1%, and 8.9%, respectively. Multiple logistic regression analyses revealed that eye irritation was significantly associated with carpeting [odds ratio (OR), 1.73; 95% confidence interval (CI), 1.24-2.41], coldness perception (OR, 1.28; 95% CI, 1.13-1.45), and air dryness perception (OR, 1.61; 95% CI, 1.42-1.82). General symptoms were significantly associated with unpleasant odors (OR, 1.37; 95% CI, 1.13-1.65), amount of work (OR, 1.24; 95% CI, 1.06-1.45), and interpersonal conflicts (OR, 1.44; 95% CI, 1.23-1.69). Upper respiratory symptoms were significantly associated with crowded workspaces (OR, 1.36; 95% CI, 1.13-1.63), air dryness perception (OR, 2.07; 95% CI, 1.79-2.38), and reported dustiness on the floor (OR, 1.39; 95% CI, 1.16-1.67). Although psychosocial support is important to reduce and control BRSs, maintaining appropriate air-conditioning and a clean and uncrowded workspace is of equal importance.

journal_name

Indoor Air

journal_title

Indoor air

authors

Azuma K,Ikeda K,Kagi N,Yanagi U,Osawa H

doi

10.1111/ina.12158

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

499-511

issue

5

eissn

0905-6947

issn

1600-0668

journal_volume

25

pub_type

杂志文章
  • A general mechanistic model for predicting the fate and transport of phthalates in indoor environments.

    abstract::A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model-predicted evolving concentrations of ben...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12514

    authors: Liang Y,Bi C,Wang X,Xu Y

    更新日期:2019-01-01 00:00:00

  • Impact of constructional energy-saving measures on radon levels indoors.

    abstract::Energy-efficient building refurbishment has the aim of saving energy and thus reducing CO2 emissions. Increased energy efficiency of a building often implies reduced air exchange. Together with other indoor air quality problems, this may lead to an increase in indoor radon concentration (Rn-222). In order to investiga...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12553

    authors: Meyer W

    更新日期:2019-07-01 00:00:00

  • Altered susceptibility to air sampling stress by filtration is related to colistin resistance development in Acinetobacter baumannii.

    abstract::The accurate quantification of antibiotic-resistant bacteria in indoor air has recently attracted increasing attention. Here, we investigated whether the susceptibility of a nosocomial infection-related microbe, Acinetobacter baumannii, to strong sampling stress caused by Nuclepore filter changes as it develops resist...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12487

    authors: Tseng CC,Yu PY,Liou JW,Chang KC

    更新日期:2018-06-26 00:00:00

  • Quantitative aerobiologic analysis of an influenza human challenge-transmission trial.

    abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12701

    authors: Bueno de Mesquita PJ,Noakes CJ,Milton DK

    更新日期:2020-11-01 00:00:00

  • Endotoxin, extracellular polysaccharides, and β(1-3)-glucan concentrations in dust and their determinants in four European birth cohorts: results from the HITEA project.

    abstract:UNLABELLED:Early-life exposure to microbial agents may play a protective role in asthma and allergies development. Geographical differences in the prevalence of these diseases exist, but the differences in early-life indoor microbial agent levels and their determinants have been hardly studied. We aimed to describe the...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12017

    authors: Casas L,Tischer C,Wouters IM,Valkonen M,Gehring U,Doekes G,Torrent M,Pekkanen J,Garcia-Esteban R,Hyvärinen A,Heinrich J,Sunyer J

    更新日期:2013-06-01 00:00:00

  • Study on the lower limit of indoor humidity subject experiments on psychological responses.

    abstract::As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negativ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12717

    authors: Takada S

    更新日期:2021-01-01 00:00:00

  • Cross-city comparison of indoor air temperatures in air-conditioned spaces.

    abstract::Field measurements were collected through physical measurements and observations in the cities of Seoul, Korea; Eugene and Portland, Oregon; and Yokohama, Japan, during the fall, winter, and summer seasons from 2005 to 2006. A total of 1733 data sets were collected (Seoul - 713; Oregon - 807; Yokohama - 213) in variet...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00705.x

    authors: Kim H,Chun C,Kwok A,Ota A,Tamura A

    更新日期:2011-08-01 00:00:00

  • Of microbes and men.

    abstract:UNLABELLED:Moisture accumulation in building structures, the microbial ecology of water-damaged sites and human exposure to biological contaminants are complex phenomena and may result in various types of indoor air pollution and adverse health outcomes. Commonly reported are building-related irritation symptoms, respi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00344.x

    authors: Nevalainen A,Seuri M

    更新日期:2005-01-01 00:00:00

  • Semivolatile organic compounds in French schools: Partitioning between the gas phase, airborne particles and settled dust.

    abstract::The indoor environmental quality in classrooms can largely affect children's daily exposure to indoor chemicals in schools. To date, there has not been a comprehensive study of the concentrations of semivolatile organic compounds (SVOCs) in French schools. Therefore, the French Observatory for Indoor Air Quality (OQAI...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12724

    authors: Wei W,Dassonville C,Sivanantham S,Gregoire A,Mercier F,Le Bot B,Malingre L,Ramalho O,Derbez M,Mandin C

    更新日期:2021-01-01 00:00:00

  • Continuous measurement of reactive oxygen species inside and outside of a residential house during summer.

    abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12789

    authors: Eftekhari A,Fortenberry CF,Williams BJ,Walker MJ,Dang A,Pfaff A,Ercal N,Morrison GC

    更新日期:2021-01-23 00:00:00

  • Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

    abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00243.x

    authors: Finlayson EU,Gadgil AJ,Thatcher TL,Sextro RG

    更新日期:2004-08-01 00:00:00

  • Levels and sources of volatile organic compounds in homes of children with asthma.

    abstract:UNLABELLED:Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total targe...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12086

    authors: Chin JY,Godwin C,Parker E,Robins T,Lewis T,Harbin P,Batterman S

    更新日期:2014-08-01 00:00:00

  • Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena.

    abstract:UNLABELLED:In this paper, a method is developed to assess the performance of adsorptive building materials that are used for reducing indoor pollutant concentrations. Mass transfer has a great influence on the materials' performance. To control the mass transfer rate precisely in the performance test, the authors have ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00316.x

    authors: Ataka Y,Kato S,Murakami S,Zhu Q,Ito K,Yokota T

    更新日期:2004-01-01 00:00:00

  • A pilot study to investigate the effects of combined dehumidification and HEPA filtration on dew point and airborne mold spore counts in day care centers.

    abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00379.x

    authors: Bernstein JA,Levin L,Crandall MS,Perez A,Lanphear B

    更新日期:2005-12-01 00:00:00

  • The field comparison of three measuring techniques for evaluation of the surface dust level in ventilation ducts.

    abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2002.120106.x

    authors: Holopainen R,Asikainen V,Pasanen P,Seppänen O

    更新日期:2002-03-01 00:00:00

  • Risk assessment of formaldehyde in typical office buildings in Taiwan.

    abstract::Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2003.00205.x

    authors: Wu PC,Li YY,Lee CC,Chiang CM,Su HJ

    更新日期:2003-12-01 00:00:00

  • Modeling the internal dynamics of energy and mass transfer in an imperfectly mixed ventilated airspace.

    abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00168.x

    authors: Janssens K,Van Brecht A,Zerihun Desta T,Boonen C,Berckmans D

    更新日期:2004-06-01 00:00:00

  • Humidity control effect of vapor-permeable walls employing hygroscopic insulation material.

    abstract::Airtight construction and high-performance thermal insulation materials are commonly considered important building features to enhance indoor thermal comfort while reducing thermal load. However, when water vapor is generated in such airtight indoor spaces, it cannot be discharged to the outside, causing interstitial ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12622

    authors: Lee H,Ozaki A,Lee M,Yamamoto T

    更新日期:2020-03-01 00:00:00

  • Exposure to ultrafine particles in children until 18 years of age: A systematic review.

    abstract::Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12620

    authors: García-Hernández C,Ferrero A,Estarlich M,Ballester F

    更新日期:2020-01-01 00:00:00

  • Exercise-induced effects on a gym atmosphere.

    abstract::We report results of analysis of a month-long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity,...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12226

    authors: Žitnik M,Bučar K,Hiti B,Barba Ž,Rupnik Z,Založnik A,Žitnik E,Rodrìguez L,Mihevc I,Žibert J

    更新日期:2016-06-01 00:00:00

  • Identification of contaminant sources in enclosed environments by inverse CFD modeling.

    abstract:UNLABELLED:In case contaminants are found in enclosed environments such as aircraft cabins or buildings, it is useful to find the contaminant sources. One method to locate contaminant sources is by inverse computational fluid dynamics (CFD) modeling. As the inverse CFD modeling is ill posed, this paper has proposed to ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00452.x

    authors: Zhang TF,Chen Q

    更新日期:2007-06-01 00:00:00

  • Quantitative filter forensics with residential HVAC filters to assess indoor concentrations.

    abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12536

    authors: Givehchi R,Maestre JP,Bi C,Wylie D,Xu Y,Kinney KA,Siegel JA

    更新日期:2019-05-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Characterizing ultrafine particles and other air pollutants at five schools in South Texas.

    abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00738.x

    authors: Zhang Q,Zhu Y

    更新日期:2012-02-01 00:00:00

  • The relationship between measured moisture conditions and fungal concentrations in water-damaged building materials.

    abstract::We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2000.010002111.x

    authors: Pasanen AL,Rautiala S,Kasanen JP,Raunio P,Rantamäki J,Kalliokoski P

    更新日期:2000-06-01 00:00:00

  • Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

    abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...

    journal_title:Indoor air

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ina.12502

    authors: Cox J,Isiugo K,Ryan P,Grinshpun SA,Yermakov M,Desmond C,Jandarov R,Vesper S,Ross J,Chillrud S,Dannemiller K,Reponen T

    更新日期:2018-11-01 00:00:00

  • Respiratory effects of experimental exposure to office dust.

    abstract:UNLABELLED:The aim of this experiment was to test if healthy persons respond to exposures to normal office dust with objective or subjective effects in a dose-related way. If they did, the importance of their personal characteristics should be investigated. This paper presents the results related to respiratory effects...

    journal_title:Indoor air

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0668.2004.00252.x

    authors: Mølhave L,Kjaergaard SK,Attermann J

    更新日期:2004-12-01 00:00:00

  • Survey of the reliability of carbon monoxide alarms deployed in domestic homes and efficacy of use by consumers.

    abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12022

    authors: Naylor S,Walsh PT,Dowker KP

    更新日期:2013-08-01 00:00:00

  • Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.

    abstract::Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEP...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12716

    authors: Barkjohn KK,Norris C,Cui X,Fang L,Zheng T,Schauer JJ,Li Z,Zhang Y,Black M,Zhang JJ,Bergin MH

    更新日期:2021-01-01 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00