Abstract:
:There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , but these predictions are sensitive to the emission rates used. Reported emission rates are highly variable and are typically for the cooking of single ingredients and not full meals. Accordingly, there is a need to assess PM2.5 emissions from the cooking of complete meals. Mean PM2.5 emission rates and source strengths were measured for four complete meals. Temporal PM2.5 concentrations and particle size distributions were recorded using an optical particle counter (OPC), and gravimetric sampling was used to determine calibration factors. Mean emission rates and source strengths varied between 0.54-3.7 mg/min and 15-68 mg, respectively, with 95% confidence. Using a cooker hood (apparent capture efficiency > 90%) and frying in non-stick pans were found to significantly reduce emissions. OPC calibration factors varied between 1.5 and 5.0 showing that a single value cannot be used for all meals and that gravimetric sampling is necessary when measuring PM2.5 concentrations in kitchens.
journal_name
Indoor Airjournal_title
Indoor airauthors
O'Leary C,de Kluizenaar Y,Jacobs P,Borsboom W,Hall I,Jones Bdoi
10.1111/ina.12542subject
Has Abstractpub_date
2019-05-01 00:00:00pages
423-438issue
3eissn
0905-6947issn
1600-0668journal_volume
29pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12127
更新日期:2015-04-01 00:00:00
abstract::This study assessed the collection efficiency (CE) of two popularly used sampling devices (BioSampler and Coriolis sampler) for fungal aerosols. Phosphate-buffered saline (PBS) supplemented with or without surfactant (Tween-20, Tween-80, or Triton X-100) and antifoam agent was prepared and used as collection liquids. ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12535
更新日期:2019-05-01 00:00:00
abstract:UNLABELLED:When considering how people are infected and what can be done to prevent the infections, answers from many disciplines are sought: microbiology, epidemiology, medicine, engineering, and physics. There are many pathways to infection spread, and among the most significant from the epidemiological point of view...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2006.00432.x
更新日期:2006-10-01 00:00:00
abstract:UNLABELLED:Building-related symptoms in office workers worldwide are common, but of uncertain etiology. One cause may be contaminants related to characteristics of heating, ventilating, and air-conditioning (HVAC) systems. We analyzed data from 97 representative air-conditioned US office buildings in the Building Asses...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00531.x
更新日期:2008-08-01 00:00:00
abstract::The microbial content of air has as yet been little described, despite its public health implications, and there remains a lack of environmental microbial data on airborne microflora in enclosed spaces. In this context, the aim of this study was to characterize the diversity and dynamics of airborne microorganisms in ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12053
更新日期:2014-02-01 00:00:00
abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00253.x
更新日期:2004-06-01 00:00:00
abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00754.x
更新日期:2012-04-01 00:00:00
abstract::This paper reports the comparison of three measuring methods for quantifying the amount of dust on the inner surface of ventilation ducts: 1) a vacuum test method; 2) a gravimetric tape method; and 3) an optical method. Thirteen recently constructed buildings were selected for the field test in the Helsinki metropolit...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2002.120106.x
更新日期:2002-03-01 00:00:00
abstract::Ventilation is pivotal in terms of securing optimum indoor air quality. In addition, it also has a major impact on energy use in buildings. It is important, therefore, that the role and impact of ventilation is fully understood and that ventilation is employed efficiently. The purpose of this paper is to review these ...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1034/j.1600-0668.2000.010003193.x
更新日期:2000-09-01 00:00:00
abstract::While household air pollution from biomass fuel combustion has been linked to cardiovascular disease, the effects on cardiac structure and function have not been well described. We sought to determine the association between biomass fuel smoke exposure and cardiac structure and function by transthoracic echocardiograp...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12362
更新日期:2017-07-01 00:00:00
abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00379.x
更新日期:2005-12-01 00:00:00
abstract::The formaldehyde emission from wood-based building materials is usually determined in large chambers at a defined temperature, humidity and ventilation rate. In this article, a simpler method, the Field and Laboratory Emission Cell (FLEC), is described for determination of the formaldehyde emission and it is compared ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.1999.00006.x
更新日期:1999-12-01 00:00:00
abstract::As a basis for determining the lower limit of acceptable humidity in an indoor environment, experiments were conducted for 25 subjects to assess the maximum expected sensations of dryness, discomfort based on humidity, and intolerance based on humidity, under conditions of 26°C and 10% RH. As results, distinct negativ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12717
更新日期:2021-01-01 00:00:00
abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12745
更新日期:2020-09-24 00:00:00
abstract::Despite evidence that airborne transmission contributes to influenza epidemics, limited knowledge of the infectiousness of human influenza cases hinders pandemic preparedness. We used airborne viral source strength and indoor CO2 monitoring from the largest human influenza challenge-transmission trial (EMIT: Evaluatin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12701
更新日期:2020-11-01 00:00:00
abstract:UNLABELLED:In Japan, organophosphate and polybrominated flame retardants are used in building materials and electric appliances to protect them from fire hazards. In this study, to identify the emission sources of these flame retardants to indoor air, the migration rates (flux) of organophosphate and polybrominated fla...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2006.00442.x
更新日期:2007-02-01 00:00:00
abstract::Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12620
更新日期:2020-01-01 00:00:00
abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00383.x
更新日期:2005-10-01 00:00:00
abstract:UNLABELLED: Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00757.x
更新日期:2012-06-01 00:00:00
abstract::The objectives of this study were (i) to assess the determinants that affect concentrations of the bacterial cell wall components 3-hydroxy fatty acids (3-OH FAs) and muramic acid and of total viable bacteria and actinomycetes in house dust; and (ii) to examine the seasonal variation and reproducibility of these bacte...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12141
更新日期:2015-06-01 00:00:00
abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2003.00183.x
更新日期:2003-09-01 00:00:00
abstract::Associations between size-fractionated indoor particulate matter (PM) and black carbon (BC) and heart rate variability (HRV) and heart rate (HR) in elderly women remain unclear. Twenty-nine healthy elderly women were measured for 24-hour HRV/HR indices. Real-time size-fractionated indoor PM and BC were monitored on th...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12449
更新日期:2018-05-01 00:00:00
abstract:UNLABELLED:This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00738.x
更新日期:2012-02-01 00:00:00
abstract:UNLABELLED:Quasi-ultrafine (quasi-UF) particulate matter (PM(0.25)) and its components were measured in indoor and outdoor environments at four retirement communities in Los Angeles Basin, California, as part of the Cardiovascular Health and Air Pollution Study (CHAPS). The present paper focuses on the characterization...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2009.00620.x
更新日期:2010-02-01 00:00:00
abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12464
更新日期:2018-07-01 00:00:00
abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...
journal_title:Indoor air
pub_type: 杂志文章,随机对照试验
doi:10.1111/ina.12502
更新日期:2018-11-01 00:00:00
abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00168.x
更新日期:2004-06-01 00:00:00
abstract::A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model-predicted evolving concentrations of ben...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12514
更新日期:2019-01-01 00:00:00
abstract:UNLABELLED:Moisture accumulation in building structures, the microbial ecology of water-damaged sites and human exposure to biological contaminants are complex phenomena and may result in various types of indoor air pollution and adverse health outcomes. Commonly reported are building-related irritation symptoms, respi...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00344.x
更新日期:2005-01-01 00:00:00
abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12332
更新日期:2017-05-01 00:00:00