Abstract:
:Concentrations and emission rates of sixteen trace elements in emitted PM during heating soybean oil using three types of pans, including Teflon, granitium, and cast-iron, were investigated. Statistically significant decreases in Mn and Co emission rates were observed when the oil was heated in the cast-iron pan compared to Teflon and granitium pans. Among the released trace elements, Ni, Ba, Zn, and Cr had more contribution to the emission rate. The concentrations of Fe in the emitted PM1 were found to be higher when cast-iron pan (8.49 ± 3.35 µg/m3 ) was utilized compared to Teflon (8.05 ± 2.27 µg/m3 ) and granitium (7.45 ± 1.38 µg/m3 ). However, these increases were statistically insignificant. The results of our study support the hypothesis that the trace elements translocate from cooking pans into the heated oil and subsequently to the particulate phase. This translocation creates a new inhalation exposure route to trace elements in indoor environments.
journal_name
Indoor Airjournal_title
Indoor airauthors
Broomandi P,Amouei Torkmahalleh M,Akturk M,Ngagine SH,Gorjinezhad S,Ozturk F,Kocak M,Kim Jdoi
10.1111/ina.12641subject
Has Abstractpub_date
2020-05-01 00:00:00pages
492-499issue
3eissn
0905-6947issn
1600-0668journal_volume
30pub_type
杂志文章相关文献
INDOOR AIR文献大全abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12745
更新日期:2020-09-24 00:00:00
abstract::There is growing awareness that indoor exposure to particulate matter with diameter ≤ 2.5 μm (PM2.5 ) is associated with an increased risk of adverse health effects. Cooking is a key indoor source of PM2.5 and an activity conducted daily in most homes. Population scale models can predict occupant exposures to PM2.5 , ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12542
更新日期:2019-05-01 00:00:00
abstract::The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available me...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12031
更新日期:2013-10-01 00:00:00
abstract:UNLABELLED:A field survey of occupants' response to the indoor environment in 10 office buildings with displacement ventilation was performed. The response of 227 occupants was analyzed. About 24% of the occupants in the survey complained that they were daily bothered by draught, mainly at the lower leg. Vertical air t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00337.x
更新日期:2005-06-01 00:00:00
abstract::Outdoor traffic-related airborne particles can infiltrate a building and adversely affect the indoor air quality. Limited information is available on the effectiveness of high efficiency particulate air (HEPA) filtration of traffic-related particles. Here, we investigated the effectiveness of portable HEPA air cleaner...
journal_title:Indoor air
pub_type: 杂志文章,随机对照试验
doi:10.1111/ina.12502
更新日期:2018-11-01 00:00:00
abstract::Reactive oxygen species (ROS) are an important contributor to adverse health effects associated with ambient air pollution. Despite infiltration of ROS from outdoors, and possible indoor sources (eg, combustion), there are limited data available on indoor ROS. In this study, part of the second phase of Air Composition...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12789
更新日期:2021-01-23 00:00:00
abstract::The photolysis of HONO has been found to be the oxidation driver through OH formation in the indoor air measurement campaign SURFin, an extensive campaign carried out in July 2012 in a classroom in Marseille. In this study, the INCA-Indoor model is used to evaluate different HONO formation mechanisms that have been us...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12320
更新日期:2017-03-01 00:00:00
abstract:UNLABELLED:Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial mont...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00408.x
更新日期:2006-04-01 00:00:00
abstract::A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model-predicted evolving concentrations of ben...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12514
更新日期:2019-01-01 00:00:00
abstract::Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside natur...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12057
更新日期:2014-04-01 00:00:00
abstract:UNLABELLED:Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneu...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2008.00533.x
更新日期:2008-08-01 00:00:00
abstract:UNLABELLED:This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is d...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00383.x
更新日期:2005-10-01 00:00:00
abstract::Indoor air quality (IAQ), as determined by the concentrations of indoor air pollutants, can be predicted using either physically based mechanistic models or statistical models that are driven by measured data. In comparison with mechanistic models mostly used in unoccupied or scenario-based environments, statistical m...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/ina.12580
更新日期:2019-09-01 00:00:00
abstract:UNLABELLED:Air movement--good or bad? The question can only be answered by those who are exposed when they are exposed. Human perception of air movement depends on environmental factors including air velocity, air velocity fluctuations, air temperature, and personal factors such as overall thermal sensation and activit...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2004.00271.x
更新日期:2004-01-01 00:00:00
abstract:UNLABELLED:The present paper outlines a modeling approach, which has been developed to model the internal dynamics of heat and moisture transfer in an imperfectly mixed ventilated airspace. The modeling approach, which combines the classical heat and moisture balance differential equations with the use of experimental ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2004.00168.x
更新日期:2004-06-01 00:00:00
abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2003.00183.x
更新日期:2003-09-01 00:00:00
abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12451
更新日期:2018-05-01 00:00:00
abstract::We developed a novel, compact upper-room ultraviolet germicidal irradiation system with light-emitting diode sources (UR-UVGI-LED) to enhance the disinfection of bioaerosols in an enclosed room space. Its effectiveness was evaluated and compared with the conventional upper-room ultraviolet germicidal irradiation syste...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12619
更新日期:2020-01-01 00:00:00
abstract:UNLABELLED:The effects of the human convective boundary layer (CBL), room airflow patterns, and their velocities on personal exposure are examined. Two pollutants are studied which simulate particles released from the feet and generated at distances of 2 and 3 m by a human cough. A thermal manikin whose body shape, siz...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12177
更新日期:2015-12-01 00:00:00
abstract::We investigated the physicochemical properties (size, shape, elemental composition, and endotoxin) of size resolved particulate matter (PM) collected from the indoor and corridor environments of classrooms. A comparative hazard profiling of these PM was conducted using human microvascular endothelial cells (HMVEC). Ox...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12341
更新日期:2017-05-01 00:00:00
abstract::Carbon monoxide (CO) alarms are extensively used in domestic premises in the UK to help protect against CO poisoning. Their expected lifetime has been increasing, and some current models now have a replacement period of more than 6 years under normal operation. However, concerns have been expressed as to the reliabili...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12022
更新日期:2013-08-01 00:00:00
abstract::It is inappropriate to use the assumption of instantaneously well-mixed zones to model airflows and pollutant transport in large indoor spaces. We investigate two approaches for describing the details of airflows in large indoor spaces, for accuracy and suitability for integration with multi-zone infiltration models. ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1034/j.1600-0668.2003.00160.x
更新日期:2003-06-01 00:00:00
abstract:UNLABELLED:Indoor exposures to allergens, mold spores, and endotoxin have been suggested as etiological agents of asthma; therefore, accurate determination of those exposures, especially in young children (6-36 months), is important for understanding the development of asthma. Because use of personal sampling equipment...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00749.x
更新日期:2012-04-01 00:00:00
abstract:UNLABELLED:A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform depos...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2005.00419.x
更新日期:2006-06-01 00:00:00
abstract::Our study conducts a series of investigations in five office buildings chosen according to the types of construction, ventilation, and building age. Formaldehyde was measured by continuous photoacoustic Multi-Gas monitor Type 1302 (Brüel & Kjaer). The 8-h average concentrations in working hours were used to estimate t...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2003.00205.x
更新日期:2003-12-01 00:00:00
abstract::Thermal stratification is established when warmer air rises and cooler air descends under thermal buoyancy. It occurs in indoor environment situations including large warehouse-type buildings, buoyancy-driven ventilated spaces with displacement, underfloor ventilation, and/or natural ventilation, and enclosure fires w...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12520
更新日期:2019-03-01 00:00:00
abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/j.1600-0668.2011.00728.x
更新日期:2011-12-01 00:00:00
abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...
journal_title:Indoor air
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0668.2011.00713.x
更新日期:2011-06-01 00:00:00
abstract::The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and ...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12609
更新日期:2020-01-01 00:00:00
abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...
journal_title:Indoor air
pub_type: 杂志文章
doi:10.1111/ina.12214
更新日期:2016-06-01 00:00:00