Exposure to organophosphate and polybrominated diphenyl ether flame retardants via indoor dust and childhood asthma.

Abstract:

:Although the ubiquitous detection of polybrominated diphenyl ether (PBDE) and organophosphate flame retardants (PFRs) in indoor dust has raised health concerns, only very few epidemiological studies have assessed their impact on human health. Inhalation of dust is one of the exposure routes of FRs, especially in children and can be hazardous for the respiratory health. Moreover, PFRs are structurally similar to organophosphate pesticides, which have been associated with allergic asthma. Thus, we investigated whether the concentrations of PFRs and PBDEs in indoor dust are associated with the development of childhood asthma. We selected 110 children who developed asthma at 4 or at 8 years old and 110 matched controls from a large prospective birth cohort (BAMSE - Barn, Allergy, Milieu Stockholm Epidemiology). We analyzed the concentrations of 7 PFRs and 21 PBDEs in dust collected around 2 months after birth from the mother's mattress. The abundance rank in dust was as follows: TBOEP⪢TPHP>mmp-TMPP>EHDPHP~TDCIPP>TCEP~TCIPP~BDE-209⪢BDE-99>BDE-47>BDE-153>BDE-183>BDE-100. There was no positive association between the FRs in mattress dust and the development of childhood asthma. In contrast, dust collected from mattresses of the mothers of children who would develop asthma contained significant lower levels of TPHP and mmp-TMPP. This study provides data on a wide range of PFRs and PBDEs in dust samples and development of asthma in children.

journal_name

Indoor Air

journal_title

Indoor air

authors

Canbaz D,van Velzen MJ,Hallner E,Zwinderman AH,Wickman M,Leonards PE,van Ree R,van Rijt LS

doi

10.1111/ina.12221

subject

Has Abstract

pub_date

2016-06-01 00:00:00

pages

403-13

issue

3

eissn

0905-6947

issn

1600-0668

journal_volume

26

pub_type

杂志文章
  • Responding to sudden pollutant releases in office buildings: 1. Framework and analysis tools.

    abstract::We describe a framework for developing response recommendations to unexpected toxic pollutant releases in commercial buildings. It may be applied in conditions where limited building- and event-specific information is available. The framework is based on a screening-level methodology to develop insights, or rules-of-t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00183.x

    authors: Sohn MD,Sextro RG,Gadgil AJ,Daisey JM

    更新日期:2003-09-01 00:00:00

  • Chemistry in indoor environments: 20 years of research.

    abstract:UNLABELLED:In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regardin...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0668.2011.00713.x

    authors: Weschler CJ

    更新日期:2011-06-01 00:00:00

  • Organic compounds as indicators of air pollution.

    abstract::The most important indoor air pollutants have already been addressed with individual national guidelines or recommendations. However, an international set of guidelines or recommendations for indoor air quality (IAQ) is needed for these pollutants based on general and uniform rules for setting such standards. A major ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.13.s.6.2.x

    authors: Mølhave L

    更新日期:2003-01-01 00:00:00

  • A pilot study to investigate the effects of combined dehumidification and HEPA filtration on dew point and airborne mold spore counts in day care centers.

    abstract:UNLABELLED:Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores t...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00379.x

    authors: Bernstein JA,Levin L,Crandall MS,Perez A,Lanphear B

    更新日期:2005-12-01 00:00:00

  • Comparison of two dust collection methods for reservoir indoor allergens and endotoxin on carpets and mattresses.

    abstract::Variable methods of dust collection may lead to uncertainty in the measurement of biomarkers. The purpose of this study was to examine the effect of two different dust collection devices on dust weight, Der p 1, Fel d 1, and endotoxin levels. We compared: (1) a nylon mesh sock inserted between the furniture attachment...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00253.x

    authors: Wickens K,Lane J,Siebers R,Ingham T,Crane J

    更新日期:2004-06-01 00:00:00

  • A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach.

    abstract::Dispersion characteristics of expiratory aerosols were investigated in an enclosure with two different idealized airflow patterns: the ceiling-return and the unidirectional downward. A multiphase numerical model, which was able to capture the polydispersity and evaporation features of the aerosols, was adopted. Experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2006.00426.x

    authors: Chao CY,Wan MP

    更新日期:2006-08-01 00:00:00

  • Spatiotemporally resolved black carbon concentration, schoolchildren's exposure and dose in Barcelona.

    abstract::At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between persona...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12214

    authors: Rivas I,Donaire-Gonzalez D,Bouso L,Esnaola M,Pandolfi M,de Castro M,Viana M,Àlvarez-Pedrerol M,Nieuwenhuijsen M,Alastuey A,Sunyer J,Querol X

    更新日期:2016-06-01 00:00:00

  • Assessment of human exposure to indoor organic contaminants via dust ingestion in Pakistan.

    abstract:UNLABELLED:  Ingestion of indoor dust has been acknowledged as an important route of exposure to organic contaminants (OCs). We investigated the presence of polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), organophosphate flame retardants (OPFRs), polychlorinated biphenyls (PCBs), and ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00757.x

    authors: Ali N,Van den Eede N,Dirtu AC,Neels H,Covaci A

    更新日期:2012-06-01 00:00:00

  • Single-particle characterization of indoor aerosol particles collected at an underground shopping area in Seoul, Korea.

    abstract:UNLABELLED:In this study, single-particle characterization of aerosol particles collected at an underground shopping area was performed for the first time. A quantitative single-particle analytical technique, low-Z particle electron probe X-ray microanalysis, was used to characterize a total of 7900 individual particle...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00677.x

    authors: Maskey S,Kang T,Jung HJ,Ro CU

    更新日期:2011-02-01 00:00:00

  • Productivity and fatigue.

    abstract:UNLABELLED:In studying productivity, effects of environmental factors have focused only on performance. However, previous studies of the impact of the environment upon performance of mental tasks generally conclude that productivity research is somewhat confusing because the results are sometimes conflicting. In experi...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00281.x

    authors: Tanabe S,Nishihara N

    更新日期:2004-01-01 00:00:00

  • Relationships between estimated flame retardant emissions and levels in indoor air and house dust.

    abstract::A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12332

    authors: Liagkouridis I,Cequier E,Lazarov B,Palm Cousins A,Thomsen C,Stranger M,Cousins IT

    更新日期:2017-05-01 00:00:00

  • Real-time measurements of PM2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes.

    abstract::Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEP...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12716

    authors: Barkjohn KK,Norris C,Cui X,Fang L,Zheng T,Schauer JJ,Li Z,Zhang Y,Black M,Zhang JJ,Bergin MH

    更新日期:2021-01-01 00:00:00

  • Building-related symptoms and inflammatory potency of dust from office buildings.

    abstract:UNLABELLED:The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2007.00493.x

    authors: Allermann L,Pejtersen J,Gunnarsen L,Poulsen OM

    更新日期:2007-12-01 00:00:00

  • Effects of energy retrofits on Indoor Air Quality in multifamily buildings.

    abstract::We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12555

    authors: Du L,Leivo V,Prasauskas T,Täubel M,Martuzevicius D,Haverinen-Shaughnessy U

    更新日期:2019-07-01 00:00:00

  • Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins.

    abstract::Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spect...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1034/j.1600-0668.2003.00175.x

    authors: Hines CJ,Waters MA,Larsson L,Petersen MR,Saraf A,Milton DK

    更新日期:2003-06-01 00:00:00

  • Classrooms' indoor environmental conditions affecting the academic achievement of students and teachers in higher education: A systematic literature review.

    abstract::This study reports the outcomes of a systematic literature review, which aims to determine the influence of four indoor environmental parameters - indoor air, thermal, acoustic, and lighting conditions -on the quality of teaching and learning and on students' academic achievement in schools for higher education, defin...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12745

    authors: Brink HW,Loomans MGLC,Mobach MP,Kort HSM

    更新日期:2020-09-24 00:00:00

  • Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only?

    abstract:UNLABELLED:In this stratified cross-sectional study in eight 'wet' and seven 'dry' schools, 1024 adolescent school children reported potentially building-related symptoms (BRS) in self-administrated questionnaires. From their classrooms dust samples were collected from floors, ventilation ducts, and air; settled dust w...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00356.x

    authors: Meyer HW,Würtz H,Suadicani P,Valbjørn O,Sigsgaard T,Gyntelberg F,Members of a Working Group under the Danish Mold in Buildings program (DAMIB).

    更新日期:2005-01-01 00:00:00

  • Organic compound characterization and source apportionment of indoor and outdoor quasi-ultrafine particulate matter in retirement homes of the Los Angeles Basin.

    abstract:UNLABELLED:Quasi-ultrafine (quasi-UF) particulate matter (PM(0.25)) and its components were measured in indoor and outdoor environments at four retirement communities in Los Angeles Basin, California, as part of the Cardiovascular Health and Air Pollution Study (CHAPS). The present paper focuses on the characterization...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2009.00620.x

    authors: Arhami M,Minguillón MC,Polidori A,Schauer JJ,Delfino RJ,Sioutas C

    更新日期:2010-02-01 00:00:00

  • Cooking fuel type, household ventilation, and the risk of acute lower respiratory illness in urban Bangladeshi children: a longitudinal study.

    abstract:UNLABELLED:Acute lower respiratory illnesses (ALRI) are the leading cause of death among children <5 years. Studies have found that biomass cooking fuels are an important risk factor for ALRI. However, few studies have evaluated the influence of natural household ventilation indicators on ALRI. The purpose of this stud...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00754.x

    authors: Murray EL,Brondi L,Kleinbaum D,McGowan JE,Van Mels C,Brooks WA,Goswami D,Ryan PB,Klein M,Bridges CB

    更新日期:2012-04-01 00:00:00

  • Measured moisture in buildings and adverse health effects: A review.

    abstract::It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of q...

    journal_title:Indoor air

    pub_type: 杂志文章,评审

    doi:10.1111/ina.12464

    authors: Mendell MJ,Macher JM,Kumagai K

    更新日期:2018-07-01 00:00:00

  • Quantitative filter forensics with residential HVAC filters to assess indoor concentrations.

    abstract::Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long-term sampling method to characterize airborne particle-bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12536

    authors: Givehchi R,Maestre JP,Bi C,Wylie D,Xu Y,Kinney KA,Siegel JA

    更新日期:2019-05-01 00:00:00

  • Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow.

    abstract:UNLABELLED:This paper reports on an investigation of the adequacy of computational fluid dynamics (CFD), using a standard Reynolds Averaged Navier-Stokes (RANS) model, for predicting dispersion of neutrally buoyant gas in a large indoor space. We used CFD to predict pollutant (dye) concentration distribution in a water...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2004.00243.x

    authors: Finlayson EU,Gadgil AJ,Thatcher TL,Sextro RG

    更新日期:2004-08-01 00:00:00

  • Particle dose estimation from frying in residential settings.

    abstract:UNLABELLED:Fumes produced during frying have been implicated as a potential cause for the increased incidence of adenocarcinoma. Particulate matter exposure has also been linked with other pulmonary and coronary disease. This study investigated the contribution of frying in residential settings to ultrafine and fine pa...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2008.00551.x

    authors: Evans GJ,Peers A,Sabaliauskas K

    更新日期:2008-12-01 00:00:00

  • Ultrafine particles from electric appliances and cooking pans: experiments suggesting desorption/nucleation of sorbed organics as the primary source.

    abstract::Ultrafine particles are observed when metal surfaces, such as heating elements in electric appliances, or even empty cooking pans, are heated. The source of the particles has not been identified. We present evidence that particles >10 nm are not emitted directly from the heating elements or the metal surfaces. Using r...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12163

    authors: Wallace LA,Ott WR,Weschler CJ

    更新日期:2015-10-01 00:00:00

  • Quantitative measurement of airborne cockroach allergen in New York City apartments.

    abstract:UNLABELLED:We designed and tested a sampling and analysis system for quantitative measurement of airborne cockroach allergen with sufficient sensitivity for residential exposure assessment. Integrated 1-week airborne particle samples were collected at 10-15 LPM in 19 New York City apartments in which an asthmatic child...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2011.00728.x

    authors: Esposito WA,Chew GL,Correa JC,Chillrud SN,Miller RL,Kinney PL

    更新日期:2011-12-01 00:00:00

  • A general mechanistic model for predicting the fate and transport of phthalates in indoor environments.

    abstract::A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model-predicted evolving concentrations of ben...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12514

    authors: Liang Y,Bi C,Wang X,Xu Y

    更新日期:2019-01-01 00:00:00

  • Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US.

    abstract::Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building vent...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12743

    authors: Myers NT,Calderón L,Pavilonis B,Wang Z,Xiong Y,Sorensen-Allacci M,Plotnik D,Senick J,Gong J,Krogmann U,Andrews CJ,Mainelis G

    更新日期:2020-09-15 00:00:00

  • Simulating the human body's microclimate using automatic coupling of CFD and an advanced thermoregulation model.

    abstract::This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of th...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/ina.12451

    authors: Voelker C,Alsaad H

    更新日期:2018-05-01 00:00:00

  • Measured concentrations of combustion gases from the use of unvented gas fireplaces.

    abstract:UNLABELLED:Measurements of combustion product concentrations were taken in 30 homes where unvented gas fireplaces were used. Measurements of CO, CO(2), NO(x), NO(2) , O(2) (depletion), and water vapor were taken at 1-min interval. The analyzers were calibrated with certified calibration gases for each placement and wer...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2010.00659.x

    authors: Francisco PW,Gordon JR,Rose B

    更新日期:2010-10-01 00:00:00

  • Indoor environmental quality in a 'low allergen' school and three standard primary schools in Western Australia.

    abstract::To investigate indoor environmental quality in classrooms, assessments were undertaken in a 'low allergen' school and three standard primary schools in Western Australia. Dust allergens, air pollutants and physical parameters were monitored in the four schools at four times (summer school term, autumn holiday, winter ...

    journal_title:Indoor air

    pub_type: 杂志文章

    doi:10.1111/j.1600-0668.2005.00405.x

    authors: Zhang G,Spickett J,Rumchev K,Lee AH,Stick S

    更新日期:2006-02-01 00:00:00