The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

Abstract:

OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on heart rate variability (HRV) parameters. APPROACH:We calculated linear (the mean and standard deviation of RR intervals, RMSSD, pNN50 and the power of the frequency components) and nonlinear (V0, V1 and V2 Porta's symbolic analysis, Shannon and Sample entropy, Guzik's and Porta's asymmetry indexes, the exponents α1 and α2 of detrended fluctuation analysis and the Hurst surface h(q,s) of multiscale multifractal analysis (MMA)) HRV parameters for 65 RR interval night-time series (39 females, 37.5(11.3) years old and 26 males, 41.7(16.5) years old; all without organic heart diseases). All parameters were calculated for original data and for the three kinds of test data in which the following parts of the time series were replaced by 1/f noise: (A) the U-shape patterns annotated in a given data set, (B) randomly chosen windows of similar size as the U-shaped patterns, (C) acceleration-deceleration events shorter than U-shaped patterns. MAIN RESULTS:We found that the U-shaped patterns, as the most persistent structures in RR night-time intervals series, affect the long-range correlation properties (measured by α2). We also found that the U-shaped patterns importantly strictly affect the shape of h(q,s) surface at different scales s. Removing the U-shaped patterns results in the shape of the h(q,s) surface losing the properties characteristic for healthy heart rhythm. The largest quantitative effect of U-shaped patterns was obtained for the power of the VLF component. The mean percentage difference of the VLF component between the original data and the A to C type test data were 19.4%, -4.3% and 5.3%, respectively. SIGNIFICANCE:Although percentage contribution of U-shaped patterns is small compared to the whole night-time series (on the average 3.1%(1.7%) with a standard deviation of 1.7%), these patterns have a considerable impact on the HRV parameters describing the VLF, persistency, nonlinear correlations and multifractal properties.

journal_name

Physiol Meas

authors

Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

doi

10.1088/1361-6579/ab9376

subject

Has Abstract

pub_date

2020-07-02 00:00:00

pages

065001

issue

6

eissn

0967-3334

issn

1361-6579

journal_volume

41

pub_type

杂志文章
  • Assessment of cerebrospinal fluid outflow conductance using an adaptive observer--experimental and clinical evaluation.

    abstract::Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have draw...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/11/003

    authors: Andersson K,Manchester IR,Andersson N,Shiriaev A,Malm J,Eklund A

    更新日期:2007-11-01 00:00:00

  • Length and activation dependent variations in muscle shear wave speed.

    abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/34/6/713

    authors: Chernak LA,DeWall RJ,Lee KS,Thelen DG

    更新日期:2013-06-01 00:00:00

  • Direct EIT Jacobian calculations for conductivity change and electrode movement.

    abstract::Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S08

    authors: Gómez-Laberge C,Adler A

    更新日期:2008-06-01 00:00:00

  • Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model.

    abstract::Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/5/001

    authors: Rodríguez I,Lequerica JL,Berjano EJ,Herrero M,Hornero F

    更新日期:2007-05-01 00:00:00

  • New electrohysterogram-based estimators of intrauterine pressure signal, tonus and contraction peak for non-invasive labor monitoring.

    abstract:BACKGROUND:Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab37db

    authors: Benalcazar-Parra C,Garcia-Casado J,Ye-Lin Y,Alberola-Rubio J,Lopez Á,Perales-Marin A,Prats-Boluda G

    更新日期:2019-09-03 00:00:00

  • Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances.

    abstract::Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/9/007

    authors: Ward LC,Essex T,Cornish BH

    更新日期:2006-09-01 00:00:00

  • Relationship between segmental and whole-body phase angle in peritoneal dialysis patients.

    abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/9/N01

    authors: Nescolarde L,Rosell-Ferrer J,Doñate T

    更新日期:2008-09-01 00:00:00

  • An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances.

    abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/008

    authors: Demidenko E

    更新日期:2011-09-01 00:00:00

  • Effects of awareness and nociception on heart rate variability during general anaesthesia.

    abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/207

    authors: Huhle R,Burghardt M,Zaunseder S,Wessel N,Koch T,Malberg H,Heller AR

    更新日期:2012-02-01 00:00:00

  • Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1035

    authors: Grychtol B,Adler A

    更新日期:2014-06-01 00:00:00

  • Adaptive filtering of ECG interference on surface EEnGs based on signal averaging.

    abstract::An external electroenterogram (EEnG) is the recording of the small bowel myoelectrical signal using contact electrodes placed on the abdominal surface. It is a weak signal affected by possible movements and by the interferences of respiration and, principally, of the cardiac signal. In this paper an adaptive filtering...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/6/005

    authors: Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2006-06-01 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • Techniques for early detection of Alzheimer's disease using spontaneous EEG recordings.

    abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/4/001

    authors: Woon WL,Cichocki A,Vialatte F,Musha T

    更新日期:2007-04-01 00:00:00

  • The feasibility of transoesophageal bioimpedance measurements for the detection of heart graft rejection.

    abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S10

    authors: Giovinazzo G,Ribas N,Cinca J,Rosell-Ferrer J

    更新日期:2011-07-01 00:00:00

  • Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation.

    abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/4/010

    authors: Hren R,Horácek BM

    更新日期:1997-11-01 00:00:00

  • A medical thermal imaging device for the prevention of diabetic foot ulceration.

    abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa56b1

    authors: Machin G,Whittam A,Ainarkar S,Allen J,Bevans J,Edmonds M,Kluwe B,Macdonald A,Petrova N,Plassmann P,Ring F,Rogers L,Simpson R

    更新日期:2017-03-01 00:00:00

  • Effect of lower body negative pressure and gravity on regional lung ventilation determined by EIT.

    abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/003

    authors: Frerichs I,Bodenstein M,Dudykevych T,Hinz J,Hahn G,Hellige G

    更新日期:2005-04-01 00:00:00

  • A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/3/002

    authors: Kong W,Huang J,Rollins DL,Ideker RE,Smith WM

    更新日期:2007-03-01 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00

  • Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy.

    abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/27/4/005

    authors: Turner AA,Lozano-Nieto A,Bouffard M

    更新日期:2006-04-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Variability in estimating shunt from single pulse oximetry measurements.

    abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/967

    authors: Karlen W,Petersen CL,Dumont GA,Ansermino JM

    更新日期:2015-05-01 00:00:00

  • Modelling the electrical properties of bladder tissue--quantifying impedance changes due to inflammation and oedema.

    abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/3/010

    authors: Walker DC,Smallwood RH,Keshtar A,Wilkinson BA,Hamdy FC,Lee JA

    更新日期:2005-06-01 00:00:00

  • Noise sensitivity of three surface ECG fibrillation detection algorithms.

    abstract::The widening application of automatic external defibrillators (AEDs) presents very strong requirements for external electrocardiogram (ECG) signal analysis. Highly accurate detection of shockable rhythms is required, aimed to approach the maximum of 100% sensitivity and specificity. In a previous study the performance...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/2/302

    authors: Jekova I,Cansell A,Dotsinsky I

    更新日期:2001-05-01 00:00:00

  • Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days.

    abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/1/308

    authors: Diskin AM,Spanel P,Smith D

    更新日期:2003-02-01 00:00:00

  • Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites.

    abstract::Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when rec...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/10/002

    authors: Kushki A,Fairley J,Merja S,King G,Chau T

    更新日期:2011-10-01 00:00:00

  • Single-sector thermophysiological human simulator.

    abstract::Thermal sweating manikins are used to analyse the heat and mass transfer phenomena in the skin-clothing-environment system. However, the limiting factor of present thermal manikins is their inability to simulate adequately the human thermal behaviour, which has a significant effect on the clothing microenvironment. A ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/2/002

    authors: Psikuta A,Richards M,Fiala D

    更新日期:2008-02-01 00:00:00

  • Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.

    abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/3/L1

    authors: Anagnostopoulou P,Egger B,Lurà M,Usemann J,Schmidt A,Gorlanova O,Korten I,Roos M,Frey U,Latzin P

    更新日期:2016-03-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00