Abstract:
:An external electroenterogram (EEnG) is the recording of the small bowel myoelectrical signal using contact electrodes placed on the abdominal surface. It is a weak signal affected by possible movements and by the interferences of respiration and, principally, of the cardiac signal. In this paper an adaptive filtering technique was proposed to identify and subsequently cancel ECG interference on canine surface EEnGs by means of a signal averaging process time-locked with the R-wave. Twelve recording sessions were carried out on six conscious dogs in the fasting state. The adaptive filtering technique used increases the signal-to-interference ratio of the raw surface EEnG from 16.7 +/- 6.5 dB up to 31.9 +/- 4.0 dB. In addition to removing ECG interference, this technique has been proven to respect intestinal SB activity, i.e. the EEnG component associated with bowel contractions, despite the fact that they overlap in the frequency domain. In this way, more robust non-invasive intestinal motility indicators can be obtained with correlation coefficients of 0.68 +/- 0.09 with internal intestinal activity. The method proposed here may also be applied to other biological recordings affected by cardiac interference and could be a very helpful tool for future applications of non-invasive recordings of gastrointestinal signals.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Garcia-Casado J,Martinez-de-Juan JL,Ponce JLdoi
10.1088/0967-3334/27/6/005subject
Has Abstractpub_date
2006-06-01 00:00:00pages
509-27issue
6eissn
0967-3334issn
1361-6579pii
S0967-3334(06)13035-Xjournal_volume
27pub_type
杂志文章abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/10/S02
更新日期:2010-10-01 00:00:00
abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/1/007
更新日期:1997-02-01 00:00:00
abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/23/1/304
更新日期:2002-02-01 00:00:00
abstract::Patients with claudication have an inadequate haemodynamic response to exercise. Blood flow response will not only have a magnitude, but also a rate of change. There is scope for investigating these parameters, as manipulation of the factors which control them may benefit work to improve the treatment for claudication...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/6/002
更新日期:2005-12-01 00:00:00
abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/9/010
更新日期:2011-09-01 00:00:00
abstract::The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure ca...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/8/1665
更新日期:2015-08-01 00:00:00
abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/1/308
更新日期:2003-02-01 00:00:00
abstract::Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/001
更新日期:2007-05-01 00:00:00
abstract::We present the results of using electrical impedance tomographic spectroscopy (EITS) to follow the changes in lung water induced by oleic acid. Measurements were made on three goats before and after the injection of oleic acid. In addition to the EITs measurements, lung water was also measured using a double-indicator...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/016
更新日期:1996-11-01 00:00:00
abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S10
更新日期:2011-07-01 00:00:00
abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/27/3/002
更新日期:2006-03-01 00:00:00
abstract::Fetal hiccups emerge as early as nine weeks post-conception, being the predominant diaphragmatic movement before 26 weeks of gestation. They are considered as a programmed isometric inspiratory muscle exercise of the fetus in preparation for the post-natal respiratory function, or a manifestation of a reflex circuitry...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/6/005
更新日期:2007-06-01 00:00:00
abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/12/F01
更新日期:2011-12-01 00:00:00
abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/7/006
更新日期:2006-07-01 00:00:00
abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/10/002
更新日期:2009-10-01 00:00:00
abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/030
更新日期:2004-02-01 00:00:00
abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/4/003
更新日期:1995-11-01 00:00:00
abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/9/008
更新日期:2010-09-01 00:00:00
abstract::The use of artificial neural networks (ANNs) to interpret sleep monitoring signals is described. Recordings from ten infants with apparent life threatening episodes were assigned into training feedforward R-PROP networks. In order to separate good signal from artefact, 60 second time frames of SaO2 and TcPO2 signals w...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/21/3/401
更新日期:2000-08-01 00:00:00
abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/34/6/713
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVE:To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND:Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physic...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab840a
更新日期:2020-05-07 00:00:00
abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab840b
更新日期:2020-05-07 00:00:00
abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S02
更新日期:2011-07-01 00:00:00
abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/019
更新日期:2005-08-01 00:00:00
abstract::EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other av...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/6/007
更新日期:2004-12-01 00:00:00
abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaaaa0
更新日期:2018-02-28 00:00:00
abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/9/004
更新日期:2007-09-01 00:00:00
abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/318
更新日期:2001-08-01 00:00:00
abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/303
更新日期:2001-02-01 00:00:00
abstract::Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/2/013
更新日期:1998-05-01 00:00:00