Comparison of EPR oximetry and Eppendorf polarographic electrode assessments of rat brain PtO2.

Abstract:

:EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other available methods. Here we report on the absolute values of rat brain PtO2 using EPR and the more widely used Eppendorf polarographic microelectrode system in the same brain. EPR used an L-band (1.2 GHz) spectrometer and implanted lithium phthalocyanine (LiPc) as the oxygen-sensitive paramagnetic material. Eppendorf measurements were made by a needle probe moved vertically through the cortex at 0.5 mm intervals in three tracks including one adjacent to the location of the LiPc. Several conclusions were drawn, including, (1) the average PtO2 measured by the two methods was similar but EPR reported a significantly higher average PtO2, (2) there was poor correlation between the values in the same animal on the same side of the brain, (3) the Eppendorf reported a larger range of values and (4) the heterogeneity of oxygen levels in the brain and the areas sampled by the two methods provide an adequate explanation for the observed differences.

journal_name

Physiol Meas

authors

O'Hara JA,Khan N,Hou H,Wilmo CM,Demidenko E,Dunn JF,Swartz HM

doi

10.1088/0967-3334/25/6/007

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

1413-23

issue

6

eissn

0967-3334

issn

1361-6579

journal_volume

25

pub_type

杂志文章
  • Machine learning for nocturnal mass diagnosis of atrial fibrillation in a population at risk of sleep-disordered breathing.

    abstract:OBJECTIVE:In this research, we introduce a new methodology for atrial fibrillation (AF) diagnosis during sleep in a large population sample at risk of sleep-disordered breathing. APPROACH:The approach leverages digital biomarkers and recent advances in machine learning (ML) for mass AF diagnosis from overnight-hours o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abb8bf

    authors: Chocron A,Efraim R,Mandel F,Rueschman M,Palmius N,Penzel T,Elbaz M,Behar JA

    更新日期:2020-11-06 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm.

    abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/27/3/002

    authors: Tarvainen MP,Georgiadis SD,Ranta-Aho PO,Karjalainen PA

    更新日期:2006-03-01 00:00:00

  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • Storage effects on the Cole-Cole parameters of erythrocyte suspensions.

    abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/7/006

    authors: Sezdi M,Bayik M,Ulgen Y

    更新日期:2006-07-01 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • Dynamic data monitoring improves predictive analytics for failed extubation in the ICU.

    abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aace95

    authors: Keim-Malpass J,Enfield KB,Calland JF,Lake DE,Clark MT

    更新日期:2018-07-16 00:00:00

  • Restoration of the electrocardiogram during mechanical cardiopulmonary resuscitation.

    abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9e53

    authors: Isasi I,Irusta U,Aramendi E,Idris AH,Sörnmo L

    更新日期:2020-11-06 00:00:00

  • A method of reducing the error caused by boundary shape and electrode positions in electrical impedance tomography.

    abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/022

    authors: Li J

    更新日期:1994-05-01 00:00:00

  • Cardiorespiratory coupling in young healthy subjects.

    abstract:OBJECTIVE:To quantify the presence of cardiorespiratory interaction in a group of 41 healthy subjects performing a subset of the Ewing test battery. APPROACH:We measure the empirical distribution of the cardiorespiratory coupling time (RI), defined as the time from inspiration onset to R peaks in the ECG. The study pr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9693

    authors: Sobiech T,Buchner T,Krzesiński P,Gielerak G

    更新日期:2017-11-30 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • A multifrequency multichannel electrical impedance data acquisition system for body fluid shift monitoring.

    abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/4/003

    authors: Lozano A,Rosell J,Pallás-Areny R

    更新日期:1995-11-01 00:00:00

  • Pulmonary perfusion measured by means of electrical impedance tomography.

    abstract::Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/2/013

    authors: Vonk Noordegraaf A,Kunst PW,Janse A,Marcus JT,Postmus PE,Faes TJ,de Vries PM

    更新日期:1998-05-01 00:00:00

  • New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/9/1624

    authors: Gade J,Greisen G

    更新日期:2016-09-01 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Relationship between detrended fluctuation analysis and spectral analysis of heart-rate variability.

    abstract::The recently-introduced technique of detrended fluctuation analysis (DFA) for heart-rate variability appears to yield improved prognostic power in cardiovascular disease through calculation of the fractal scaling exponent alpha. However, the physiological meaning of alpha remains unclear. In DFA, the signal is segment...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/2/314

    authors: Willson K,Francis DP,Wensel R,Coats AJ,Parker KH

    更新日期:2002-05-01 00:00:00

  • Invasive and noninvasive means of measuring intracranial pressure: a review.

    abstract::Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space ar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa7256

    authors: Zhang X,Medow JE,Iskandar BJ,Wang F,Shokoueinejad M,Koueik J,Webster JG

    更新日期:2017-07-24 00:00:00

  • Characteristic impedance: frequency or time domain approach?

    abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9d60

    authors: Qureshi MU,Colebank MJ,Schreier DA,Tabima DM,Haider MA,Chesler NC,Olufsen MS

    更新日期:2018-01-31 00:00:00

  • Are ejection fractions from gated SPECT perfusion studies clinically useful? A comparison with radionuclide ventriculography.

    abstract::Gated SPECT (GSPECT) was evaluated for the measurement of left ventricular ejection fraction (LVEF) by comparing with equilibrium gated radionuclide ventriculography (RNVG). A total of 99 subjects underwent GSPECT and RNVG imaging. All studies were acquired in list mode with GSPECT studies processed to give 16- and 8-...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/22/2/312

    authors: Wright GA,McDade M,Keeble W,Martin W,Hutton I

    更新日期:2001-05-01 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Assessment of the dynamic interactions between heart rate and arterial pressure by the cross time-frequency analysis.

    abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/3/315

    authors: Orini M,Laguna P,Mainardi LT,Bailón R

    更新日期:2012-03-01 00:00:00

  • A medical thermal imaging device for the prevention of diabetic foot ulceration.

    abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa56b1

    authors: Machin G,Whittam A,Ainarkar S,Allen J,Bevans J,Edmonds M,Kluwe B,Macdonald A,Petrova N,Plassmann P,Ring F,Rogers L,Simpson R

    更新日期:2017-03-01 00:00:00

  • An efficient unsupervised fetal QRS complex detection from abdominal maternal ECG.

    abstract::Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing commu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1607

    authors: Varanini M,Tartarisco G,Billeci L,Macerata A,Pioggia G,Balocchi R

    更新日期:2014-08-01 00:00:00

  • Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.

    abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/3/L1

    authors: Anagnostopoulou P,Egger B,Lurà M,Usemann J,Schmidt A,Gorlanova O,Korten I,Roos M,Frey U,Latzin P

    更新日期:2016-03-01 00:00:00

  • Wearable oxygen uptake and energy expenditure monitors.

    abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab3827

    authors: Tamura T

    更新日期:2019-09-03 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00