Abstract:
OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for monitoring of the body regions' blood-filling redistribution and to analyze the dynamics of blood-filling redistribution during rotation in three SRC rotation modes. APPROACH:Nine healthy male volunteers have been observed under three SRC rotation modes with a maximum acceleration of 2.05 standard Earth gravity (g), 2.47 g, 2.98 g along the body vertical axis towards the legs with a rotation radius of 235 cm. The 5 kHz electrical resistance was evaluated using a bioimpedance analyzer in a polysegmental mode. MAIN RESULTS:Twenty-five correct records were made, of which four records were incomplete since the tests had to be stopped because the subjects were not feeling well. There was a blood-filling decrease in the head region; resistance increased to +15.4% ± 4.1% in the first SRC rotation mode. The electrical resistance of the leg regions decreased to -16.5% ± 2.3%. Slowdown of the SRC led to the reverse changes in resistance. The blood redistribution in the head and leg regions was independent of the mode of SRC rotation during the first 30 min, and varied on average by +10% and -15% respectively. SIGNIFICANCE:Bioimpedance monitoring is promising for detection and prediction of blood circulation changes during rotation on the SRC.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DVdoi
10.1088/1361-6579/ab840bsubject
Has Abstractpub_date
2020-05-07 00:00:00pages
044006issue
4eissn
0967-3334issn
1361-6579journal_volume
41pub_type
杂志文章abstract::Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have draw...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/11/003
更新日期:2007-11-01 00:00:00
abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/030
更新日期:2004-02-01 00:00:00
abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/2/357
更新日期:2003-05-01 00:00:00
abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/1/007
更新日期:1997-02-01 00:00:00
abstract:OBJECTIVE:The ratio of the partial pressure of arterial oxygen to fraction of inspired oxygen is a key component of the sequential organ failure assessment score that operationally defines sepsis. But, it is calculated infrequently due to the need for the acquisition of an arterial blood gas. So, we sought to find an o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab5154
更新日期:2019-12-03 00:00:00
abstract::The postural stability of 30 normal subjects in the age range 15 to 64 years was measured on five separate occasions, using the sway magnetometry technique, to determine the day-to-day repeatability of this measurement technique. On each occasion the pathlength and area enclosed by movement of the hips in a horizontal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/2/003
更新日期:1998-05-01 00:00:00
abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/301
更新日期:2001-02-01 00:00:00
abstract::The state-dependent portion of cardio-vagal baroreflex control is called baroreflex hyteresis: we observe hysteresis when RR interval and carotid diameter depend on both the direction and value of arterial pressure. The elasticity of arterial walls, as well as the responsiveness of central command reset controls the r...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/6/009
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVE:Accurate bladder size estimation is an important clinical parameter that assists physicians, enabling them to provide better treatment for patients who are suffering from urinary incontinence. Electrical impedance tomography (EIT) is a non-invasive medical imaging method that estimates organ boundaries assumi...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abaa56
更新日期:2020-12-18 00:00:00
abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abc0b6
更新日期:2020-12-11 00:00:00
abstract::Plethysmographic measurement of airway resistance (R(aw)) has been determined by single-point analysis, usually at 50% of maximum inspiratory flow (MIF). Computer-assisted (best fit) analysis, however, allows R(aw) to be calculated by applying a regression line to any portion of the plethysmograph pressure-flow loop. ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/2/304
更新日期:2002-05-01 00:00:00
abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/2/303
更新日期:2000-05-01 00:00:00
abstract::Impedance cardiography (ICG) has been proposed to estimate the stroke volume (SV) and cardiac output (CO) in various medical indications. The aim of this study was to explore the reliability of ICG during pregnancy with respect to SV and CO measurements. Blood pressure, heart rate and thoracic impedance were monitored...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/6/1015
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abdf3d
更新日期:2021-01-22 00:00:00
abstract::The measurement of the complex respiratory impedance at a high temporal resolution is described. The measurement of impedance is correlated with the breathing cycle using electrical transthoracic impedance. This allows the determination of the complex impedance at any fixed point in the respiratory cycle, which result...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/3/019
更新日期:1993-08-01 00:00:00
abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/1361-6579/aab2ef
更新日期:2018-04-20 00:00:00
abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/27/3/002
更新日期:2006-03-01 00:00:00
abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba80f
更新日期:2020-09-04 00:00:00
abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/006
更新日期:1996-11-01 00:00:00
abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa6d00
更新日期:2017-06-01 00:00:00
abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/3/002
更新日期:2007-03-01 00:00:00
abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/019
更新日期:2005-08-01 00:00:00
abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/8/006
更新日期:2006-08-01 00:00:00
abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/6/022
更新日期:2005-12-01 00:00:00
abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa56b1
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abcdf4
更新日期:2020-12-31 00:00:00
abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/31/6/007
更新日期:2010-06-01 00:00:00
abstract::Epidemiological studies have associated the negative effects of sedentary time and sedentary patterns on health indices. However, these studies have used methodologies that do not directly measure the sedentary state. Recent technological developments in the area of motion sensors have incorporated inclinometers, whic...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/11/1887
更新日期:2012-11-01 00:00:00
abstract::EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other av...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/6/007
更新日期:2004-12-01 00:00:00
abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/3/008
更新日期:1997-08-01 00:00:00