A medical thermal imaging device for the prevention of diabetic foot ulceration.

Abstract:

:In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on healthy volunteers to set a robust baseline for the overall research aims and the second on  >100 patients at high risk of DFU. In the second phase of the project the objective is to demonstrate significant reduction in the incidence of DFU through a comparison of the results of standard care of high risk feet with standard care plus thermal imaging.

journal_name

Physiol Meas

authors

Machin G,Whittam A,Ainarkar S,Allen J,Bevans J,Edmonds M,Kluwe B,Macdonald A,Petrova N,Plassmann P,Ring F,Rogers L,Simpson R

doi

10.1088/1361-6579/aa56b1

subject

Has Abstract

pub_date

2017-03-01 00:00:00

pages

420-430

issue

3

eissn

0967-3334

issn

1361-6579

journal_volume

38

pub_type

杂志文章
  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • Detection of acute periodontal pain from physiological signals.

    abstract:OBJECTIVE:To investigate the feasibility of the detection of brief orofacial pain sensations from easily recordable physiological signals by means of machine learning techniques. APPROACH:A total of 47 subjects underwent periodontal probing and indicated each instance of pain perception by means of a push button. Simu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aadf0c

    authors: Teichmann D,Klopp J,Hallmann A,Schuett K,Wolfart S,Teichmann M

    更新日期:2018-09-27 00:00:00

  • Recording of ENGs from the nerves innervating the pancreas of a dog during the intravenous glucose tolerance test.

    abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/4/309

    authors: Rozman J,Zorko B,Bunc M,Mikac U,Tegou E

    更新日期:2002-11-01 00:00:00

  • Wavelet-based real-time calculation of multiple physiological parameters on an embedded platform.

    abstract:OBJECTIVE:This paper aims to present how physiological signals can be processed based on wavelet decomposition to calculate multiple physiological parameters in real-time on an embedded platform. APPROACH:An ECG and PPG are decomposed to the appropriate scale based on a quadratic spline wavelet base in order to obtain...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab6f52

    authors: Tang M,Xia P,He Z,Zhao Z,Chen X,Yang T,Zhang Z,Zhan Q,Li X,Fang Z

    更新日期:2020-03-06 00:00:00

  • Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1149

    authors: Khor JM,Tizzard A,Demosthenous A,Bayford R

    更新日期:2014-06-01 00:00:00

  • Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery.

    abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/002

    authors: Alam I,Lewis MJ,Morgan J,Baxter J

    更新日期:2009-07-01 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • A novel curve fitting method for AV optimisation of biventricular pacemakers.

    abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/36/9/1889

    authors: Dehbi HM,Jones S,Sohaib SM,Finegold JA,Siggers JH,Stegemann B,Whinnett ZI,Francis DP

    更新日期:2015-09-01 00:00:00

  • The effect of ambient air temperature on whole-body bioelectrical impedance.

    abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/011

    authors: Buono MJ,Burke S,Endemann S,Graham H,Gressard C,Griswold L,Michalewicz B

    更新日期:2004-02-01 00:00:00

  • Techniques for early detection of Alzheimer's disease using spontaneous EEG recordings.

    abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/4/001

    authors: Woon WL,Cichocki A,Vialatte F,Musha T

    更新日期:2007-04-01 00:00:00

  • Compressive sensing in electrical impedance tomography for breathing monitoring.

    abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab0daa

    authors: Shiraz A,Khodadad D,Nordebo S,Yerworth R,Frerichs I,van Kaam A,Kallio M,Papadouri T,Bayford R,Demosthenous A

    更新日期:2019-04-03 00:00:00

  • Characteristic impedance: frequency or time domain approach?

    abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9d60

    authors: Qureshi MU,Colebank MJ,Schreier DA,Tabima DM,Haider MA,Chesler NC,Olufsen MS

    更新日期:2018-01-31 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00

  • Localization of sources of brain alpha/theta/delta activity and the influence of the mode of spontaneous mentation.

    abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4a/004

    authors: Michel CM,Henggeler B,Brandeis D,Lehmann D

    更新日期:1993-11-01 00:00:00

  • An automated quasi-continuous capillary refill timing device.

    abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/83

    authors: Blaxter LL,Morris DE,Crowe JA,Henry C,Hill S,Sharkey D,Vyas H,Hayes-Gill BR

    更新日期:2016-01-01 00:00:00

  • Independent component analysis of normal and abnormal rhythm in twin pregnancies.

    abstract::We investigated the utility of ICA for evaluation of fetal rhythm in five uncomplicated twin pregnancies and in five twin pregnancies complicated by fetal arrhythmia. Using objective and subjective criteria, we sought to determine how the signal-to-noise ratio, signal fidelity and interference rejection are affected w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/1/004

    authors: Mensah-Brown NA,Lutter WJ,Comani S,Strasburger JF,Wakai RT

    更新日期:2011-01-01 00:00:00

  • Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation.

    abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/4/010

    authors: Hren R,Horácek BM

    更新日期:1997-11-01 00:00:00

  • Short-term studies of heart rate variability: comparison of two methods for recording.

    abstract::Heart rate variability (HRV) is often analysed using short-term studies. Our objective was to compare two of them in a group of diabetic patients (reduced HRV) and in a control group. From the same 10 min surface electrocardiogram (ECG) two recordings were obtained. In one of them the whole signal was acquired through...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/6/n01

    authors: Migliaro ER,Canetti R,Contreras P,Hakas M,Eirea G,Machado A

    更新日期:2004-12-01 00:00:00

  • Gastrointestinal arrhythmias are associated with statistically significant fluctuations in systemic information dimension.

    abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/5/N01

    authors: Irimia A,Wikswo JP Jr

    更新日期:2008-05-01 00:00:00

  • Validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake.

    abstract::The purpose of this study was to determine the validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake (VO2max). Fifty-two healthy volunteers had their VO2max determined during a maximal treadmill run. They also performed a timed 5 km cycle ergometer ride. The resistance setting ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1088/0967-3334/17/4/009

    authors: Buono MJ,Borin TL,Sjoholm NT,Hodgdon JA

    更新日期:1996-11-01 00:00:00

  • An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallers.

    abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/009

    authors: Weiss A,Herman T,Plotnik M,Brozgol M,Giladi N,Hausdorff JM

    更新日期:2011-12-01 00:00:00

  • An optimized lead system for long-term esophageal electrocardiography.

    abstract::Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/517

    authors: Niederhauser T,Haeberlin A,Marisa T,Mattle D,Abächerli R,Goette J,Jacomet M,Vogel R

    更新日期:2014-04-01 00:00:00

  • Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    abstract::False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1298

    authors: Liu C,Zhao L,Tang H,Li Q,Wei S,Li J

    更新日期:2016-08-01 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT.

    abstract::The increasing use of EIT in clinical research on severely ill lung patients requires a clarification of the influence of pathologic impedance distributions on the validity of the resulting tomograms. Significant accumulation of low-conducting air (e.g. pneumothorax or emphysema) or well-conducting liquid (e.g. haemat...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/5/S16

    authors: Hahn G,Just A,Dudykevych T,Frerichs I,Hinz J,Quintel M,Hellige G

    更新日期:2006-05-01 00:00:00

  • The origin of skin-stretch-caused motion artifacts under electrodes.

    abstract::The outside of the skin of the forearm is typically 15 mV more negative than the inside. Stretching the skin causes a reduction in the magnitude of this skin potential V, which we observe as a motion artifact delta V. We seek to determine the origin of this motion artifact by successively stripping 12 layers of the sk...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/2/003

    authors: de Talhouet H,Webster JG

    更新日期:1996-05-01 00:00:00

  • Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

    abstract::A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/4/010

    authors: Hovorka R,Canonico V,Chassin LJ,Haueter U,Massi-Benedetti M,Orsini Federici M,Pieber TR,Schaller HC,Schaupp L,Vering T,Wilinska ME

    更新日期:2004-08-01 00:00:00