The origin of skin-stretch-caused motion artifacts under electrodes.

Abstract:

:The outside of the skin of the forearm is typically 15 mV more negative than the inside. Stretching the skin causes a reduction in the magnitude of this skin potential V, which we observe as a motion artifact delta V. We seek to determine the origin of this motion artifact by successively stripping 12 layers of the skin using Scotch Tape. Between each stripping we measure artifact delta V, 13 Hz impedance Z, and change in impedance delta Z. On the interior surface of the forearm, Z decreases with number of strippings. delta Z can be first either positive or negative, then is always negative and decreases linearly with Z. delta V first remains constant and then decreases with Z and delta Z. delta V and delta Z increase with stretch force following a logarithmic relationship. delta Z has a rectangular shape waveform, whereas the rising edge of delta V shows a fast followed by a slow component and its falling edge decays exponentially with a large time constant. We have expanded the model of Thakor and Webster to best fit the waveform of delta V and delta Z caused by stretch.

journal_name

Physiol Meas

authors

de Talhouet H,Webster JG

doi

10.1088/0967-3334/17/2/003

subject

Has Abstract

pub_date

1996-05-01 00:00:00

pages

81-93

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

17

pub_type

杂志文章
  • Noise sensitivity of three surface ECG fibrillation detection algorithms.

    abstract::The widening application of automatic external defibrillators (AEDs) presents very strong requirements for external electrocardiogram (ECG) signal analysis. Highly accurate detection of shockable rhythms is required, aimed to approach the maximum of 100% sensitivity and specificity. In a previous study the performance...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/2/302

    authors: Jekova I,Cansell A,Dotsinsky I

    更新日期:2001-05-01 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • The possible role of the vagal nervous system in the recovery of the blood pressure control after cardiac arrest: a porcine model study.

    abstract::Previous studies have proved that the baroreceptor reflex (baroreflex) control of heart rate can be used for stratification of post-infarction population and, in general, cardiovascular disease populations. Many methods have been proposed to estimate the so-called baroreflex sensitivity (BRS) expressed as ms mmhg-1. M...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/38/1/63

    authors: Lavanga M,Baselli G,Fumagalli F,Ristagno G,Ferrario M

    更新日期:2017-01-01 00:00:00

  • Assessment of 1-lead and 2-lead electrode patterns in electrical impedance endotomography.

    abstract::Electrical impedance endotomography (EIE) is a modality of impedance imaging where the electrodes are located on an insulating core placed at the centre of the region of interest. The absence of a physical limit to the medium surrounding the probe enables the use of remote electrodes. The present study compares the fe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/001

    authors: Fournier-Desseux A,Jossinet J

    更新日期:2005-08-01 00:00:00

  • Tracking boundary movement and exterior shape modelling in lung EIT imaging.

    abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1119

    authors: Biguri A,Grychtol B,Adler A,Soleimani M

    更新日期:2015-06-01 00:00:00

  • Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

    abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/040

    authors: Ahadzi GM,Liston AD,Bayford RH,Holder DS

    更新日期:2004-02-01 00:00:00

  • Relationship between segmental and whole-body phase angle in peritoneal dialysis patients.

    abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/9/N01

    authors: Nescolarde L,Rosell-Ferrer J,Doñate T

    更新日期:2008-09-01 00:00:00

  • Time-frequency analysis of heart rate variability using short-time fourier analysis.

    abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/2/303

    authors: Elsenbruch S,Wang Z,Orr WC,Chen JD

    更新日期:2000-05-01 00:00:00

  • A method of reducing the error caused by boundary shape and electrode positions in electrical impedance tomography.

    abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/022

    authors: Li J

    更新日期:1994-05-01 00:00:00

  • Localization of sources of brain alpha/theta/delta activity and the influence of the mode of spontaneous mentation.

    abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4a/004

    authors: Michel CM,Henggeler B,Brandeis D,Lehmann D

    更新日期:1993-11-01 00:00:00

  • Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs.

    abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1439

    authors: Svenmarker S,Häggmark S,Johansson G,Axelsson B,Wiklund U,Haney M

    更新日期:2014-07-01 00:00:00

  • Non-invasive, side-selective nasal airflow monitoring.

    abstract::Nasal obstruction disturbs comfort during daytime, and sleep quality. Convenient objective assessment of nasal ventilation would be desirable. Therefore, we developed a technique for unobtrusive monitoring of bilateral nasal airflow. Nasal cannulae with separated left- and right-sided tubings were connected to two pre...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/1/007

    authors: Kohler M,Thurnheer R,Bloch KE

    更新日期:2005-02-01 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1435

    authors: Di Marco LY,Duan W,Bojarnejad M,Zheng D,King S,Murray A,Langley P

    更新日期:2012-09-01 00:00:00

  • Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

    abstract::A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/4/010

    authors: Hovorka R,Canonico V,Chassin LJ,Haueter U,Massi-Benedetti M,Orsini Federici M,Pieber TR,Schaller HC,Schaupp L,Vering T,Wilinska ME

    更新日期:2004-08-01 00:00:00

  • In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray.

    abstract::A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system befo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/2/001

    authors: Tucker AS,Ross EA,Paugh-Miller J,Sadleir RJ

    更新日期:2011-02-01 00:00:00

  • Comprehensive analysis of cardiac health using heart rate signals.

    abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/5/005

    authors: Acharya U R,Kannathal N,Krishnan SM

    更新日期:2004-10-01 00:00:00

  • False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.

    abstract::Electrocardiograms (ECGs) recorded from patients in intensive care were investigated to quantify any relationship between ECG signal quality and false monitoring alarms. False alarms are a considerable problem for nursing and medical staff as they distract from clinical care, and are also a problem for patients as the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1383

    authors: Tsimenidis C,Murray A

    更新日期:2016-08-01 00:00:00

  • Phase shift between respiratory oscillations in cerebral blood flow velocity and arterial blood pressure.

    abstract::We aim to investigate whether phase shift between respiratory oscillations in cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) is associated with changes in cerebral autoregulation (CA) or reflects the mechano-elastic properties of the cerebrovascular bed. The relationships between respiratory pha...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/38/2/310

    authors: Uryga A,Placek MM,Wachel P,Szczepański T,Czosnyka M,Kasprowicz M

    更新日期:2017-02-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms.

    abstract::The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/1/318

    authors: Al Hatib F,Trendafilova E,Daskalov I

    更新日期:2000-02-01 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography.

    abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/030

    authors: Park C,Park EJ,Woo EJ,Kwon O,Seo JK

    更新日期:2004-02-01 00:00:00

  • Validity of an activity monitor in young people with cerebral palsy gross motor function classification system level I.

    abstract::The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, wa...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/11/2307

    authors: O' Donoghue D,Kennedy N

    更新日期:2014-11-01 00:00:00

  • Masticatory muscle activity during deliberately performed oral tasks.

    abstract::The aim of this study was to investigate masticatory muscle activity during deliberately performed functional and non-functional oral tasks. Electromyographic (EMG) surface activity was recorded unilaterally from the masseter, anterior temporalis and suprahyoid muscles in 11 subjects (5 men, 6 women; age = 34.6 +/- 10...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/12/004

    authors: Farella M,Palla S,Erni S,Michelotti A,Gallo LM

    更新日期:2008-12-01 00:00:00

  • Direct EIT Jacobian calculations for conductivity change and electrode movement.

    abstract::Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S08

    authors: Gómez-Laberge C,Adler A

    更新日期:2008-06-01 00:00:00

  • 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approach.

    abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/012

    authors: Morucci JP,Granié M,Lei M,Chabert M,Marsili PM

    更新日期:1995-08-01 00:00:00

  • The independent components of auditory P300 and CNV evoked potentials derived from single-trial recordings.

    abstract::The back-projected independent components (BICs) of single-trial, auditory P300 and contingent negative variation (CNV) evoked potentials (EPs) were derived using independent component analysis (ICA) and cluster analysis. The method was tested in simulation including a study of the electric dipole equivalents of the s...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/8/001

    authors: Jervis B,Belal S,Camilleri K,Cassar T,Bigan C,Linden DE,Michalopoulos K,Zervakis M,Besleaga M,Fabri S,Muscat J

    更新日期:2007-08-01 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • Wavelet bidomain sample entropy analysis to predict spontaneous termination of atrial fibrillation.

    abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/1/005

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-01-01 00:00:00