Direct EIT Jacobian calculations for conductivity change and electrode movement.

Abstract:

:Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods reconstruct both the boundary deformation and conductivity change from the measured data. These techniques require the calculation of the 'movement Jacobian', reflecting measurement changes due to the boundary deformation. Previous papers have calculated this Jacobian using perturbation techniques, which are slow (requiring multiple solutions of the forward problem) and become inaccurate with increasing finite element model size. This effect has limited reconstruction algorithms for deformable media to mostly 2D. To address this problem, we propose a direct method to calculate the Jacobian, based on a formulation of the derivatives of the finite element system matrix with respect to geometry changes. An illustrative example of these calculations is given, as well as a comparison between the proposed method and a perturbation method. Results show this method is approximately 300 times faster; and for larger model sizes, the perturbation method begins to diverge from those from the direct method proposed.

journal_name

Physiol Meas

authors

Gómez-Laberge C,Adler A

doi

10.1088/0967-3334/29/6/S08

subject

Has Abstract

pub_date

2008-06-01 00:00:00

pages

S89-99

issue

6

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(08)67915-0

journal_volume

29

pub_type

杂志文章
  • Recording of ENGs from the nerves innervating the pancreas of a dog during the intravenous glucose tolerance test.

    abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/4/309

    authors: Rozman J,Zorko B,Bunc M,Mikac U,Tegou E

    更新日期:2002-11-01 00:00:00

  • Gastrointestinal arrhythmias are associated with statistically significant fluctuations in systemic information dimension.

    abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/5/N01

    authors: Irimia A,Wikswo JP Jr

    更新日期:2008-05-01 00:00:00

  • Monitoring nasal conductance by bilateral nasal cannula pressure transducers.

    abstract::Nasal obstruction is common and may disturb well-being during daytime and sleep. Its objective assessment by standard methods requires patient cooperation and inconvenient instrumentation. Therefore, the purpose of this study was to develop a novel, unobtrusive technique for continuous monitoring of changes in nasal c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/014

    authors: Thurnheer R,Bloch KE

    更新日期:2004-04-01 00:00:00

  • Daily physical activity patterns from hip- and wrist-worn accelerometers.

    abstract::Accelerometer wear location may influence physical activity estimates. This study investigates this relationship through the examination of activity patterns throughout the day. Participants from the aging research evaluating accelerometry (AREA) study (n men  =  37, n women  =  47, mean age (SD)  =  78.9 (5.5) years)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1852

    authors: Shiroma EJ,Schepps MA,Harezlak J,Chen KY,Matthews CE,Koster A,Caserotti P,Glynn NW,Harris TB

    更新日期:2016-10-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms.

    abstract::The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V(1) reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF or...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/1/007

    authors: Alcaraz R,Hornero F,Rieta JJ

    更新日期:2011-01-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

    abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/022

    authors: Andersson N,Malm J,Bäcklund T,Eklund A

    更新日期:2005-12-01 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Automatic sleep-stage scoring based on photoplethysmographic signals.

    abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921d

    authors: Wu X,Yang J,Pan Y,Zhang X,Luo Y

    更新日期:2020-06-30 00:00:00

  • Monitoring fetal maturation-objectives, techniques and indices of autonomic function.

    abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/aa5fca

    authors: Hoyer D,Żebrowski J,Cysarz D,Gonçalves H,Pytlik A,Amorim-Costa C,Bernardes J,Ayres-de-Campos D,Witte OW,Schleußner E,Stroux L,Redman C,Georgieva A,Payne S,Clifford G,Signorini MG,Magenes G,Andreotti F,Malberg H,Zaun

    更新日期:2017-05-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • Within-breath measurement of respiratory impedance.

    abstract::The measurement of the complex respiratory impedance at a high temporal resolution is described. The measurement of impedance is correlated with the breathing cycle using electrical transthoracic impedance. This allows the determination of the complex impedance at any fixed point in the respiratory cycle, which result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/3/019

    authors: van der Putten WJ,MacLeod D,Prichard JS

    更新日期:1993-08-01 00:00:00

  • Automatic detection of detached and erroneous electrodes in electrical impedance tomography.

    abstract::One unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper presents an automatic approach to detect such erroneous electrodes. It is based on the assumption that all valid m...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/2/017

    authors: Asfaw Y,Adler A

    更新日期:2005-04-01 00:00:00

  • Effects of awareness and nociception on heart rate variability during general anaesthesia.

    abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/207

    authors: Huhle R,Burghardt M,Zaunseder S,Wessel N,Koch T,Malberg H,Heller AR

    更新日期:2012-02-01 00:00:00

  • Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites.

    abstract::Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when rec...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/10/002

    authors: Kushki A,Fairley J,Merja S,King G,Chau T

    更新日期:2011-10-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography.

    abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/030

    authors: Park C,Park EJ,Woo EJ,Kwon O,Seo JK

    更新日期:2004-02-01 00:00:00

  • Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

    abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/018

    authors: Allen J,Oates CP,Lees TA,Murray A

    更新日期:2005-10-01 00:00:00

  • Characterization of the work-time relationship during cross-country ski ergometry.

    abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/31

    authors: Fukuda DH,Hetrick RP,Kendall KL,Smith-Ryan AE,Jackson ME,Stout JR

    更新日期:2014-01-01 00:00:00

  • Single-sector thermophysiological human simulator.

    abstract::Thermal sweating manikins are used to analyse the heat and mass transfer phenomena in the skin-clothing-environment system. However, the limiting factor of present thermal manikins is their inability to simulate adequately the human thermal behaviour, which has a significant effect on the clothing microenvironment. A ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/2/002

    authors: Psikuta A,Richards M,Fiala D

    更新日期:2008-02-01 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • Dynamic time warping and machine learning for signal quality assessment of pulsatile signals.

    abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1491

    authors: Li Q,Clifford GD

    更新日期:2012-09-01 00:00:00

  • A novel curve fitting method for AV optimisation of biventricular pacemakers.

    abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/36/9/1889

    authors: Dehbi HM,Jones S,Sohaib SM,Finegold JA,Siggers JH,Stegemann B,Whinnett ZI,Francis DP

    更新日期:2015-09-01 00:00:00

  • Detection of animal tissue thickness using simple vertical electric sounding (VES).

    abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/1/007

    authors: Gonzalez CA,offniga O,Padilla LE

    更新日期:1997-02-01 00:00:00

  • Comprehensive analysis of cardiac health using heart rate signals.

    abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/5/005

    authors: Acharya U R,Kannathal N,Krishnan SM

    更新日期:2004-10-01 00:00:00

  • Prediction of sustained harmonic walking in the free-living environment using raw accelerometry data.

    abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa74d

    authors: Urbanek JK,Zipunnikov V,Harris T,Fadel W,Glynn N,Koster A,Caserotti P,Crainiceanu C,Harezlak J

    更新日期:2018-02-28 00:00:00

  • Characterization of cardiorespiratory phase synchronization and directionality in late premature and full term infants.

    abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac553

    authors: Lucchini M,Pini N,Fifer WP,Burtchen N,Signorini MG

    更新日期:2018-06-19 00:00:00

  • Invasive and noninvasive means of measuring intracranial pressure: a review.

    abstract::Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space ar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa7256

    authors: Zhang X,Medow JE,Iskandar BJ,Wang F,Shokoueinejad M,Koueik J,Webster JG

    更新日期:2017-07-24 00:00:00