Recording of ENGs from the nerves innervating the pancreas of a dog during the intravenous glucose tolerance test.

Abstract:

:Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the cuffs platinum electrodes were arranged in three parallel spiral groups containing 11 electrodes on the inner surface. The cuffs had an inner diameter of 2 mm and a length of 18 mm. In a two-year study, the cuffs were implanted into two Beagle dogs and were also used for pancreatic stimulation, although this is not described in this paper. In the VN, the cuff was installed on the nerve at the neck, whilst in the SN, the cuff was installed on the nerve before the celiac ganglion, and in the PN, the cuff was installed on the nerve just before it enters the pancreas. Six months after implantation, when the model of interpretation of the results was developed, three recordings of ENG in each animal were conducted. The first one was conducted in the unstimulated pancreas while the second and the third were conducted 1 and 8 min after a known amount of glucose was i.v. administered. Since the results obtained in both animals were actually quite similar, we present the results obtained in one animal. To evaluate the changes in superficial activity of the nerves, elicited by the administration of glucose, the power spectra corresponding to ENGs, recorded from the nerves before and after the administration of glucose, were integrated within the band of frequencies ranging from 1 to 5 kHz. Accordingly, the magnitude of the integrated power spectrum (MIPS), corresponding to the ENG recorded from the SN before administration of glucose, was 2.863 au. One minute after glucose was administered the value fell to 2.795 au while 8 min after the administration the value returned to 2.8 au. The MIPS corresponding to the ENG recorded from the PN before the administration of glucose was 3.236 au. One minute after the administration the value fell to 2.901 au while 8 min after the administration the value rose to 3.009 au. The MIPS, corresponding to the ENG recorded from the VN before the administration of glucose, was 3.656 au. One minute after the administration the value fell to 3.565 au. Eight minutes after the administration the value rose to 3.689 au. The results show that 1 min after glucose was administered superficial activity in all three nerves was reduced while 8 min after administration the activity in the nerves returned to the same level of activity before the glucose was administered. This information could be effectively used in a further study of pancreatic innervation and its function. Moreover, the results suggest that cuffs could also be useful in recording the ENGs from other nerves of the autonomic nervous system that innervate various glands and internal organs.

journal_name

Physiol Meas

authors

Rozman J,Zorko B,Bunc M,Mikac U,Tegou E

doi

10.1088/0967-3334/23/4/309

subject

Has Abstract

pub_date

2002-11-01 00:00:00

pages

695-705

issue

4

eissn

0967-3334

issn

1361-6579

journal_volume

23

pub_type

杂志文章
  • Infrared thermography for indirect assessment of activation of brown adipose tissue in lean and obese male subjects.

    abstract::Brown adipose tissue (BAT) plays a key role in adaptive thermogenesis in mammals, and it has recently been considered as an attractive therapeutic target for tackling human obesity by increasing energy expenditure. Thermal imaging using infrared thermography (IRT) has emerged as a potential safe, rapid and inexpensive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/12/N118

    authors: El Hadi H,Frascati A,Granzotto M,Silvestrin V,Ferlini E,Vettor R,Rossato M

    更新日期:2016-12-01 00:00:00

  • Time-frequency analysis of heart rate variability using short-time fourier analysis.

    abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/2/303

    authors: Elsenbruch S,Wang Z,Orr WC,Chen JD

    更新日期:2000-05-01 00:00:00

  • Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT.

    abstract::We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially gene...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/8/S06

    authors: Hahn G,Dittmar J,Just A,Quintel M,Hellige G

    更新日期:2010-08-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • A wireless platform for in vivo measurement of resistance properties of the gastrointestinal tract.

    abstract::Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule in...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1197

    authors: Natali CD,Beccani M,Obstein KL,Valdastri P

    更新日期:2014-07-01 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Cardiorespiratory coupling in young healthy subjects.

    abstract:OBJECTIVE:To quantify the presence of cardiorespiratory interaction in a group of 41 healthy subjects performing a subset of the Ewing test battery. APPROACH:We measure the empirical distribution of the cardiorespiratory coupling time (RI), defined as the time from inspiration onset to R peaks in the ECG. The study pr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9693

    authors: Sobiech T,Buchner T,Krzesiński P,Gielerak G

    更新日期:2017-11-30 00:00:00

  • Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.

    abstract::Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The exp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S19

    authors: Frerichs I,Schmitz G,Pulletz S,Schädler D,Zick G,Scholz J,Weiler N

    更新日期:2007-07-01 00:00:00

  • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/026

    authors: Nopp P,Zhao TX,Brown BH,Wang W

    更新日期:1996-11-01 00:00:00

  • Quantifying agitation in sedated ICU patients using heart rate and blood pressure.

    abstract::Agitation is a significant problem in the intensive care unit (ICU), affecting 71% of sedated adult patients during 58% of ICU patient-days (Fraser and Riker 2001 NY Health-Syst. Pharm. 20 17-24). Subjective scale-based assessment methods are currently used to assess the level of patient agitation, but are limited in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/4/020

    authors: Chase JG,Starfinger C,Lam Z,Agogue F,Shaw GM

    更新日期:2004-08-01 00:00:00

  • A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/3/002

    authors: Kong W,Huang J,Rollins DL,Ideker RE,Smith WM

    更新日期:2007-03-01 00:00:00

  • Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

    abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/001

    authors: Brown BH,Barber DC,Wang W,Lu L,Leathard AD,Smallwood RH,Hampshire AR,Mackay R,Hatzigalanis K

    更新日期:1994-05-01 00:00:00

  • Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation.

    abstract:OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subs...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaeb2

    authors: Zhao Z,Wang W,Zhang Z,Xu M,Frerichs I,Wu J,Moeller K

    更新日期:2018-03-29 00:00:00

  • Trabecular thickness measurement in cancellous bones: postmortem rat studies with the zoom-in micro-tomography technique.

    abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/008

    authors: Cho MH,Chun IK,Lee SC,Cho MH,Lee SY

    更新日期:2005-10-01 00:00:00

  • New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/9/1624

    authors: Gade J,Greisen G

    更新日期:2016-09-01 00:00:00

  • Adaptive techniques in electrical impedance tomography reconstruction.

    abstract::We present an adaptive algorithm for solving the inverse problem in electrical impedance tomography. To strike a balance between the accuracy of the reconstructed images and the computational efficiency of the forward and inverse solvers, we propose to combine an adaptive mesh refinement technique with the adaptive Ka...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1111

    authors: Li T,Isaacson D,Newell JC,Saulnier GJ

    更新日期:2014-06-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool.

    abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/308

    authors: Bayford RH,Gibson A,Tizzard A,Tidswell T,Holder DS

    更新日期:2001-02-01 00:00:00

  • Fetal beat detection in abdominal ECG recordings: global and time adaptive approaches.

    abstract::We present a method for location of fetal QRS in maternal abdominal ECG recordings. This method's initial, global approach was proposed in the context of the 2013 PhysioNet/Computing in Cardiology Challenge where it was tested on the 447 four channel one-minute recordings.The first step is filtering to eliminate basel...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1699

    authors: Rodrigues R

    更新日期:2014-08-01 00:00:00

  • Effect of organic and inorganic nitrates on cerebrovascular pulsatile power transmission in patients with heart failure and preserved ejection fraction.

    abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1361-6579/aab2ef

    authors: Londono-Hoyos F,Zamani P,Beraun M,Vasim I,Segers P,Chirinos JA

    更新日期:2018-04-20 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • A novel curve fitting method for AV optimisation of biventricular pacemakers.

    abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/36/9/1889

    authors: Dehbi HM,Jones S,Sohaib SM,Finegold JA,Siggers JH,Stegemann B,Whinnett ZI,Francis DP

    更新日期:2015-09-01 00:00:00

  • Prediction of sustained harmonic walking in the free-living environment using raw accelerometry data.

    abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa74d

    authors: Urbanek JK,Zipunnikov V,Harris T,Fadel W,Glynn N,Koster A,Caserotti P,Crainiceanu C,Harezlak J

    更新日期:2018-02-28 00:00:00

  • Combined electrocardiogram and photoplethysmogram measurements as an indicator of objective sleepiness.

    abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/8/001

    authors: Chua CP,McDarby G,Heneghan C

    更新日期:2008-08-01 00:00:00

  • Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation.

    abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac9a9

    authors: Harju J,Tarniceriu A,Parak J,Vehkaoja A,Yli-Hankala A,Korhonen I

    更新日期:2018-06-27 00:00:00

  • Validation of a finite-element solution for electrical impedance tomography in an anisotropic medium.

    abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S10

    authors: Abascal JF,Arridge SR,Lionheart WR,Bayford RH,Holder DS

    更新日期:2007-07-01 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • Feasibility of long-term cerebral and peripheral regional tissue oxygen saturation measurements.

    abstract::The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1349

    authors: Schmitz J,Pichler G,Schwaberger B,Urlesberger B,Baik N,Binder C

    更新日期:2014-07-01 00:00:00