Abstract:
:Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that automatically detects a respiratory region of interest (RoI) and signal using a camera. Based on the observation that respiration induced chest/abdomen motion is an independent motion system in a video, our basic idea is to exploit the intrinsic properties of respiration to find the respiratory RoI and extract the respiratory signal via motion factorization. We created a benchmark dataset containing 148 video sequences obtained on adults under challenging conditions and also neonates in the neonatal intensive care unit (NICU). The measurements obtained by the proposed video respiration monitoring (VRM) method are not significantly different from the reference methods (guided breathing or contact-based ECG; p-value = 0.6), and explain more than 99% of the variance of the reference values with low limits of agreement (-2.67 to 2.81 bpm). VRM seems to provide a valid solution to ECG in confined motion scenarios, though precision may be reduced for neonates. More studies are needed to validate VRM under challenging recording conditions, including upper-body motion types.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Janssen R,Wang W,Moço A,de Haan Gdoi
10.1088/0967-3334/37/1/100subject
Has Abstractpub_date
2016-01-01 00:00:00pages
100-14issue
1eissn
0967-3334issn
1361-6579journal_volume
37pub_type
杂志文章abstract::Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/9/007
更新日期:2006-09-01 00:00:00
abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/10/S02
更新日期:2010-10-01 00:00:00
abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abcdf4
更新日期:2020-12-31 00:00:00
abstract::Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almos...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/33/2/243
更新日期:2012-02-01 00:00:00
abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/31/5/008
更新日期:2010-05-01 00:00:00
abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/001
更新日期:1994-05-01 00:00:00
abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/1/83
更新日期:2016-01-01 00:00:00
abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/5/005
更新日期:2004-10-01 00:00:00
abstract::The widening application of automatic external defibrillators (AEDs) presents very strong requirements for external electrocardiogram (ECG) signal analysis. Highly accurate detection of shockable rhythms is required, aimed to approach the maximum of 100% sensitivity and specificity. In a previous study the performance...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/2/302
更新日期:2001-05-01 00:00:00
abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/8/006
更新日期:2006-08-01 00:00:00
abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/9/N01
更新日期:2008-09-01 00:00:00
abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/008
更新日期:2005-10-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba6a1
更新日期:2021-01-01 00:00:00
abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/12/2529
更新日期:2014-12-01 00:00:00
abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/6/1149
更新日期:2014-06-01 00:00:00
abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/24/2/310
更新日期:2003-05-01 00:00:00
abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/303
更新日期:2001-02-01 00:00:00
abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/001
更新日期:2004-02-01 00:00:00
abstract:OBJECTIVE:Observational studies suggest that obesity might have a Mendelian origin, but it is not clear if gene expression patterns observed in obese subjects are secondary to genetic traits or not. APPROACH:Here we test a transcriptomic signature of obesity previously identified by our group on a large cohort of twin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aab85a
更新日期:2018-04-26 00:00:00
abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac7aa
更新日期:2018-06-25 00:00:00
abstract:OBJECTIVE:It is accepted that changes in the peripheral pulse waveform characteristics occur with ageing. Pulse risetime is one important feature which has clinical value. However, it is unclear how it varies across the full age spectrum from child to senior and for different peripheral measurement sites. The objective...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9b67
更新日期:2020-08-11 00:00:00
abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/8/1273
更新日期:2016-08-01 00:00:00
abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab7ddf
更新日期:2020-04-17 00:00:00
abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/N61
更新日期:2015-03-01 00:00:00
abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/7/006
更新日期:2006-07-01 00:00:00
abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/28/2/007
更新日期:2007-02-01 00:00:00
abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/25/5/015
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9d60
更新日期:2018-01-31 00:00:00
abstract::The measurement of the complex respiratory impedance at a high temporal resolution is described. The measurement of impedance is correlated with the breathing cycle using electrical transthoracic impedance. This allows the determination of the complex impedance at any fixed point in the respiratory cycle, which result...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/3/019
更新日期:1993-08-01 00:00:00
abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/4/544
更新日期:2016-04-01 00:00:00