Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances.

Abstract:

:Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, nonlinear curve fitting. An alternative fitting method is described that uses only the magnitude of the measured impedances at four selected frequencies. The two methods showed excellent agreement when compared using data obtained both from measurements of equivalent circuits and of humans. These results suggest that operational equivalence to a technically complex, frequency-scanning, phase-sensitive BIS analyser could be achieved from a simple four-frequency, impedance-only analyser.

journal_name

Physiol Meas

authors

Ward LC,Essex T,Cornish BH

doi

10.1088/0967-3334/27/9/007

subject

Has Abstract

pub_date

2006-09-01 00:00:00

pages

839-50

issue

9

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(06)18497-X

journal_volume

27

pub_type

杂志文章
  • Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging.

    abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/12/2529

    authors: Long X,Yang J,Weysen T,Haakma R,Foussier J,Fonseca P,Aarts RM

    更新日期:2014-12-01 00:00:00

  • Causality in physiological signals.

    abstract::Health is one of the most important non-material assets and thus also has an enormous influence on material values, since treating and preventing diseases is expensive. The number one cause of death worldwide today originates in cardiovascular diseases. For these reasons the aim of understanding the functions and the ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/37/5/R46

    authors: Müller A,Kraemer JF,Penzel T,Bonnemeier H,Kurths J,Wessel N

    更新日期:2016-05-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00

  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • A pH-mucosa area unit of measure to consider morphology of the oesophagus when evaluating oesophagitis.

    abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/4/006

    authors: Haylett KR,Vales P,Lee SH,McCloy RF

    更新日期:2003-11-01 00:00:00

  • Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

    abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/018

    authors: Allen J,Oates CP,Lees TA,Murray A

    更新日期:2005-10-01 00:00:00

  • A multifrequency multichannel electrical impedance data acquisition system for body fluid shift monitoring.

    abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/4/003

    authors: Lozano A,Rosell J,Pallás-Areny R

    更新日期:1995-11-01 00:00:00

  • Time-related heart autonomic balance characteristics in healthy subjects.

    abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/3/309

    authors: Matveev M,Prokopova R,Nachev Ch

    更新日期:2003-08-01 00:00:00

  • A new method for measurement of gas exchange during anaesthesia using an extractable marker gas.

    abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/001

    authors: Peyton PJ,Robinson GJ,Terry D,Junor PA

    更新日期:2004-02-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

    abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/022

    authors: Andersson N,Malm J,Bäcklund T,Eklund A

    更新日期:2005-12-01 00:00:00

  • Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs.

    abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1439

    authors: Svenmarker S,Häggmark S,Johansson G,Axelsson B,Wiklund U,Haney M

    更新日期:2014-07-01 00:00:00

  • Novel technology to help understand the context of physical activity and sedentary behaviour.

    abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1834

    authors: Loveday A,Sherar LB,Sanders JP,Sanderson PW,Esliger DW

    更新日期:2016-10-01 00:00:00

  • Ballistocardiography and seismocardiography detection of hemodynamic changes during simulated obstructive apnea.

    abstract:OBJECTIVE:To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS:Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab924b

    authors: Morra S,Hossein A,Gorlier D,Rabineau J,Chaumont M,Migeotte PF,Van De Borne P

    更新日期:2020-07-09 00:00:00

  • Sensitivity matrix and reconstruction algorithm for EIT assuming axial uniformity.

    abstract::In electrical impedance tomography (EIT) two-dimensional models continue to be applied despite their known inability to provide correct reconstruction. In this paper, a reconstruction algorithm that assumes a translationally invariant conductivity distribution is described. A more precise forward solver is obtained by...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/1/308

    authors: Jerbi K,Lionheart WR,Vauhkonen PJ,Vauhkonen M

    更新日期:2000-02-01 00:00:00

  • Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/367

    authors: Lee BI,Oh SH,Woo EJ,Lee SY,Cho MH,Kwon O,Seo JK,Baek WS

    更新日期:2003-05-01 00:00:00

  • Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs.

    abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1273

    authors: Krasteva V,Jekova I,Leber R,Schmid R,Abächerli R

    更新日期:2016-08-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Pilot acute study of feedback-controlled retrograde peristalsis invoked by neural gastric electrical stimulation.

    abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/3/006

    authors: Aelen P,Jurkov A,Aulanier A,Mintchev MP

    更新日期:2009-03-01 00:00:00

  • Monitoring nasal conductance by bilateral nasal cannula pressure transducers.

    abstract::Nasal obstruction is common and may disturb well-being during daytime and sleep. Its objective assessment by standard methods requires patient cooperation and inconvenient instrumentation. Therefore, the purpose of this study was to develop a novel, unobtrusive technique for continuous monitoring of changes in nasal c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/014

    authors: Thurnheer R,Bloch KE

    更新日期:2004-04-01 00:00:00

  • The effect of serial data collection on the accuracy of electrical impedance tomography images.

    abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/6/659

    authors: Yerworth R,Bayford R

    更新日期:2013-06-01 00:00:00

  • Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms.

    abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/357

    authors: Patterson RP,Zhang J

    更新日期:2003-05-01 00:00:00

  • Patient examinations using electrical impedance tomography--sources of interference in the intensive care unit.

    abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/F01

    authors: Frerichs I,Pulletz S,Elke G,Gawelczyk B,Frerichs A,Weiler N

    更新日期:2011-12-01 00:00:00

  • Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

    abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2/002

    authors: Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

    更新日期:1994-05-01 00:00:00

  • Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats--a pilot study.

    abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/010

    authors: Huang YJ,Huang EY,Lu YY,Chen CY,Cheng KS

    更新日期:2011-09-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Modelling of the immunoassay element of an optical immunosensor.

    abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/318

    authors: Keating SM,Flanagan MT

    更新日期:2001-08-01 00:00:00

  • Electrical impedance myography at frequencies up to 2 MHz.

    abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/29/6/S29

    authors: Shiffman CA,Kashuri H,Aaron R

    更新日期:2008-06-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00