Abstract:
OBJECTIVE:Brain waves vary between people. This work aims to improve automatic sleep staging for longitudinal sleep monitoring via personalization of algorithms based on individual characteristics extracted from sleep data recorded during the first night. APPROACH:As data from a single night are very small, thereby making model training difficult, we propose a Kullback-Leibler (KL) divergence regularized transfer learning approach to address this problem. We employ the pretrained SeqSleepNet (i.e. the subject independent model) as a starting point and finetune it with the single-night personalization data to derive the personalized model. This is done by adding the KL divergence between the output of the subject independent model and it of the personalized model to the loss function during finetuning. In effect, KL-divergence regularization prevents the personalized model from overfitting to the single-night data and straying too far away from the subject independent model. MAIN RESULTS:Experimental results on the Sleep-EDF Expanded database consisting of 75 subjects show that sleep staging personalization with single-night data is possible with help of the proposed KL-divergence regularization. On average, we achieve a personalized sleep staging accuracy of 79.6%, a Cohen's kappa of 0.706, a macro F1-score of 73.0%, a sensitivity of 71.8%, and a specificity of 94.2%. SIGNIFICANCE:We find both that the approach is robust against overfitting and that it improves the accuracy by 4.5 percentage points compared to the baseline method without personalization and 2.2 percentage points compared to it with personalization but without regularization.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Phan H,Mikkelsen K,Chén OY,Koch P,Mertins A,Kidmose P,De Vos Mdoi
10.1088/1361-6579/ab921esubject
Has Abstractpub_date
2020-07-01 00:00:00pages
064004issue
6eissn
0967-3334issn
1361-6579journal_volume
41pub_type
杂志文章abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/N61
更新日期:2015-03-01 00:00:00
abstract::Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Dopp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/11/2003
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac9a9
更新日期:2018-06-27 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00
abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/5/807
更新日期:2014-05-01 00:00:00
abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/3a/021
更新日期:1995-08-01 00:00:00
abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab3827
更新日期:2019-09-03 00:00:00
abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/3/309
更新日期:2003-08-01 00:00:00
abstract::Brown adipose tissue (BAT) plays a key role in adaptive thermogenesis in mammals, and it has recently been considered as an attractive therapeutic target for tackling human obesity by increasing energy expenditure. Thermal imaging using infrared thermography (IRT) has emerged as a potential safe, rapid and inexpensive...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/12/N118
更新日期:2016-12-01 00:00:00
abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/1/31
更新日期:2014-01-01 00:00:00
abstract::We aim to investigate whether phase shift between respiratory oscillations in cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) is associated with changes in cerebral autoregulation (CA) or reflects the mechano-elastic properties of the cerebrovascular bed. The relationships between respiratory pha...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/38/2/310
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9d60
更新日期:2018-01-31 00:00:00
abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1785
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa1d3
更新日期:2018-01-31 00:00:00
abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/6/022
更新日期:2005-12-01 00:00:00
abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/001
更新日期:1994-05-01 00:00:00
abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/3/006
更新日期:2008-03-01 00:00:00
abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/3/002
更新日期:2007-03-01 00:00:00
abstract::Muscle injuries in the lower limb are common among professional football players. Classification is made according to severity and is diagnosed with radiological assessment as: grade I (minor strain or minor injury), grade II (partial rupture, moderate injury) and grade III (complete rupture, severe injury). Tetrapola...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/1/27
更新日期:2015-01-01 00:00:00
abstract::Gated SPECT (GSPECT) was evaluated for the measurement of left ventricular ejection fraction (LVEF) by comparing with equilibrium gated radionuclide ventriculography (RNVG). A total of 99 subjects underwent GSPECT and RNVG imaging. All studies were acquired in list mode with GSPECT studies processed to give 16- and 8-...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/22/2/312
更新日期:2001-05-01 00:00:00
abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/001
更新日期:2004-02-01 00:00:00
abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/1/55
更新日期:2014-01-01 00:00:00
abstract::Previous studies have proved that the baroreceptor reflex (baroreflex) control of heart rate can be used for stratification of post-infarction population and, in general, cardiovascular disease populations. Many methods have been proposed to estimate the so-called baroreflex sensitivity (BRS) expressed as ms mmhg-1. M...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/38/1/63
更新日期:2017-01-01 00:00:00
abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/3/008
更新日期:1997-08-01 00:00:00
abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S02
更新日期:2011-07-01 00:00:00
abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab7ddf
更新日期:2020-04-17 00:00:00
abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1439
更新日期:2014-07-01 00:00:00
abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/308
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:In this research, we introduce a new methodology for atrial fibrillation (AF) diagnosis during sleep in a large population sample at risk of sleep-disordered breathing. APPROACH:The approach leverages digital biomarkers and recent advances in machine learning (ML) for mass AF diagnosis from overnight-hours o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abb8bf
更新日期:2020-11-06 00:00:00