Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

Abstract:

:Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait characteristics. Furthermore, this may be exacerbated by testing protocol (different walking speed) and age. Therefore, the aim of this study was to examine the effect of an accelerometer-based wearable(s) (accW) location, walking speed, age and algorithms on gait characteristics. Forty younger (YA) and 40 older adults (OA) were recruited. Participants wore accW positioned at the chest, waist and lower back (L5, gold standard) and were asked to walk continuously for 2 min at preferred and fast speeds. Two algorithms, previously validated for accW located on L5, were used to quantify step time and step length. Mean, variability and asymmetry gait characteristics were estimated for each location with reference to L5. To examine impact of locations and speed on algorithm-dependant characteristic evaluation, adjustments were made to the temporal algorithm. Absolute, relative agreement and difference between measurements at different locations and L5 were assessed. Mean step time and length evaluated from the chest showed excellent agreement compared to L5 for both age groups and speeds. Agreement between waist and L5 was excellent for mean step time for both speeds and age groups, good for mean step length at both speeds for YA and at preferred speed for OA. Step time and length asymmetry evaluated from the chest showed moderate agreement for YA only. Lastly, results showed that algorithm adjustment did not influence agreement between results obtained at different locations. Mean spatiotemporal characteristics can be robustly quantified from accW at the locations used in this study irrespective of speed and age; this is not true when estimating variability and asymmetry characteristics.

journal_name

Physiol Meas

authors

Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

doi

10.1088/0967-3334/37/10/1785

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1785-1797

issue

10

eissn

0967-3334

issn

1361-6579

journal_volume

37

pub_type

杂志文章
  • Predicting clinical ischaemia during awake carotid endarterectomy: use of the SJVO2 probe as a guide to selective shunting.

    abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/2/310

    authors: Crossman J,Banister K,Bythell V,Bullock R,Chambers I,Mendelow AD

    更新日期:2003-05-01 00:00:00

  • 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approach.

    abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/012

    authors: Morucci JP,Granié M,Lei M,Chabert M,Marsili PM

    更新日期:1995-08-01 00:00:00

  • A comparison of methods for measurement of spatial resolution in two-dimensional circular EIT images.

    abstract::The literature concerning measurement of spatial resolution in electrical impedance tomography (EIT) is vague. Different groups often use their own method or a modified version of a better known method, thus hindering a generalized resolution measurement which could be useful for gauging the performance of one system ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/1/316

    authors: Wheeler JL,Wang W,Tang M

    更新日期:2002-02-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/1163

    authors: Riknagel D,Dinesen B,Zimmermann H,Farlie R,Schmidt S,Toft E,Struijk JJ

    更新日期:2016-07-01 00:00:00

  • An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances.

    abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/008

    authors: Demidenko E

    更新日期:2011-09-01 00:00:00

  • Wearable oxygen uptake and energy expenditure monitors.

    abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab3827

    authors: Tamura T

    更新日期:2019-09-03 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • Recognition of elementary arm movements using orientation of a tri-axial accelerometer located near the wrist.

    abstract::In this paper we present a method for recognising three fundamental movements of the human arm (reach and retrieve, lift cup to mouth, rotation of the arm) by determining the orientation of a tri-axial accelerometer located near the wrist. Our objective is to detect the occurrence of such movements performed with the ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/9/1751

    authors: Biswas D,Corda D,Baldus G,Cranny A,Maharatna K,Achner J,Klemke J,Jöbges M,Ortmann S

    更新日期:2014-09-01 00:00:00

  • In vivo measurement of human skin absorption of topically applied substances by a photoacoustic technique.

    abstract::A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/3/304

    authors: Gutiérrez-Juárez G,Vargas-Luna M,Córdova T,Varela JB,Bernal-Alvarado JJ,Sosa M

    更新日期:2002-08-01 00:00:00

  • Body fat prediction from skinfold anthropometry referenced to a new gold standard: in vivo neutron activation analysis and tritium dilution.

    abstract::Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat....

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/3/008

    authors: Beddoe AH,Samat SB

    更新日期:1998-08-01 00:00:00

  • Impedance analyser module for EIT and spectroscopy using undersampling.

    abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/303

    authors: Dudykevych T,Gersing E,Thiel F,Hellige G

    更新日期:2001-02-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab7ac

    authors: Ivanović MD,Petrovic J,Savić A,Gligorić G,Miletić M,Vukčević M,Bojović B,Hadžievski L,Allsop T,Webb DJ

    更新日期:2018-04-26 00:00:00

  • Effect of composition on the dielectric properties of hydrogels for biomedical applications.

    abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/S02

    authors: Alexe-Ionescu AL,Barbero G,Freire FC,Merletti R

    更新日期:2010-10-01 00:00:00

  • Gastric activity studies using a magnetic tracer.

    abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/5/015

    authors: Cordova-Fraga T,Bernal-Alvarado JJ,Gutierrez-Juarez G,Sosa M,Vargas-Luna M

    更新日期:2004-10-01 00:00:00

  • Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients.

    abstract::A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes cl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/11/1931

    authors: Schwenk M,Gogulla S,Englert S,Czempik A,Hauer K

    更新日期:2012-11-01 00:00:00

  • Comparison of different passive knee extension torque-angle assessments.

    abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1483

    authors: Freitas SR,Vaz JR,Bruno PM,Valamatos MJ,Mil-Homens P

    更新日期:2013-11-01 00:00:00

  • Relationship between detrended fluctuation analysis and spectral analysis of heart-rate variability.

    abstract::The recently-introduced technique of detrended fluctuation analysis (DFA) for heart-rate variability appears to yield improved prognostic power in cardiovascular disease through calculation of the fractal scaling exponent alpha. However, the physiological meaning of alpha remains unclear. In DFA, the signal is segment...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/2/314

    authors: Willson K,Francis DP,Wensel R,Coats AJ,Parker KH

    更新日期:2002-05-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Magnetographic assessment of fetal hiccups and their effect on fetal heart rhythm.

    abstract::Fetal hiccups emerge as early as nine weeks post-conception, being the predominant diaphragmatic movement before 26 weeks of gestation. They are considered as a programmed isometric inspiratory muscle exercise of the fetus in preparation for the post-natal respiratory function, or a manifestation of a reflex circuitry...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/6/005

    authors: Popescu EA,Popescu M,Bennett TL,Lewine JD,Drake WB,Gustafson KM

    更新日期:2007-06-01 00:00:00

  • Empirical estimators of gamma fits to tracer-dilution curves and their technical basis and practical scope.

    abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/4/401

    authors: Lopatatzidis A,Millard RK

    更新日期:2001-11-01 00:00:00

  • Aging in autonomic control by multifractal studies of cardiac interbeat intervals in the VLF band.

    abstract::The heart rate responds dynamically to various intrinsic and environmental stimuli. The autonomic nervous system is said to play a major role in this response. Multifractal analysis offers a novel method to assess the response of cardiac interbeat intervals. Twenty-four hour ECG recordings of RR interbeat intervals (o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/10/014

    authors: Makowiec D,Rynkiewicz A,Wdowczyk-Szulc J,Zarczyńska-Buchowiecka M,Gałaska R,Kryszewski S

    更新日期:2011-10-01 00:00:00

  • In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray.

    abstract::A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system befo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/2/001

    authors: Tucker AS,Ross EA,Paugh-Miller J,Sadleir RJ

    更新日期:2011-02-01 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Non-constrained monitoring of systolic blood pressure on a weighing scale.

    abstract::In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured usin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/011

    authors: Shin JH,Lee KM,Park KS

    更新日期:2009-07-01 00:00:00

  • A multi-frequency EIT system design based on telecommunication signal processors.

    abstract::A multi-frequency electrical impedance tomography system for cardiopulmonary monitoring has been designed with specialized digital signal processors developed primarily for the telecommunications sector. The system consists of two modules: a scan-head and a base-station. The scan-head, located close to the patient's t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/6/S04

    authors: Robitaille N,Guardo R,Maurice I,Hartinger AE,Gagnon H

    更新日期:2009-06-01 00:00:00

  • Storage effects on the Cole-Cole parameters of erythrocyte suspensions.

    abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/7/006

    authors: Sezdi M,Bayik M,Ulgen Y

    更新日期:2006-07-01 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • Airway resistance estimation by best fit analysis in very premature infants.

    abstract::Plethysmographic measurement of airway resistance (R(aw)) has been determined by single-point analysis, usually at 50% of maximum inspiratory flow (MIF). Computer-assisted (best fit) analysis, however, allows R(aw) to be calculated by applying a regression line to any portion of the plethysmograph pressure-flow loop. ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/2/304

    authors: Thomas M,Greenough A,Blowes R,Rafferty GF,Calvert S,Marlow N,Peacock JL,Milner AD

    更新日期:2002-05-01 00:00:00