Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

Abstract:

:Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait characteristics. Furthermore, this may be exacerbated by testing protocol (different walking speed) and age. Therefore, the aim of this study was to examine the effect of an accelerometer-based wearable(s) (accW) location, walking speed, age and algorithms on gait characteristics. Forty younger (YA) and 40 older adults (OA) were recruited. Participants wore accW positioned at the chest, waist and lower back (L5, gold standard) and were asked to walk continuously for 2 min at preferred and fast speeds. Two algorithms, previously validated for accW located on L5, were used to quantify step time and step length. Mean, variability and asymmetry gait characteristics were estimated for each location with reference to L5. To examine impact of locations and speed on algorithm-dependant characteristic evaluation, adjustments were made to the temporal algorithm. Absolute, relative agreement and difference between measurements at different locations and L5 were assessed. Mean step time and length evaluated from the chest showed excellent agreement compared to L5 for both age groups and speeds. Agreement between waist and L5 was excellent for mean step time for both speeds and age groups, good for mean step length at both speeds for YA and at preferred speed for OA. Step time and length asymmetry evaluated from the chest showed moderate agreement for YA only. Lastly, results showed that algorithm adjustment did not influence agreement between results obtained at different locations. Mean spatiotemporal characteristics can be robustly quantified from accW at the locations used in this study irrespective of speed and age; this is not true when estimating variability and asymmetry characteristics.

journal_name

Physiol Meas

authors

Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

doi

10.1088/0967-3334/37/10/1785

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1785-1797

issue

10

eissn

0967-3334

issn

1361-6579

journal_volume

37

pub_type

杂志文章
  • Preliminary static EIT images of the thorax in health and disease.

    abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/23/1/304

    authors: Cherepenin V,Karpov A,Korjenevsky A,Kornienko V,Kultiasov Y,Mazaletskaya A,Mazourov D

    更新日期:2002-02-01 00:00:00

  • New electrohysterogram-based estimators of intrauterine pressure signal, tonus and contraction peak for non-invasive labor monitoring.

    abstract:BACKGROUND:Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab37db

    authors: Benalcazar-Parra C,Garcia-Casado J,Ye-Lin Y,Alberola-Rubio J,Lopez Á,Perales-Marin A,Prats-Boluda G

    更新日期:2019-09-03 00:00:00

  • Effects of awareness and nociception on heart rate variability during general anaesthesia.

    abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/207

    authors: Huhle R,Burghardt M,Zaunseder S,Wessel N,Koch T,Malberg H,Heller AR

    更新日期:2012-02-01 00:00:00

  • Independent component analysis of normal and abnormal rhythm in twin pregnancies.

    abstract::We investigated the utility of ICA for evaluation of fetal rhythm in five uncomplicated twin pregnancies and in five twin pregnancies complicated by fetal arrhythmia. Using objective and subjective criteria, we sought to determine how the signal-to-noise ratio, signal fidelity and interference rejection are affected w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/1/004

    authors: Mensah-Brown NA,Lutter WJ,Comani S,Strasburger JF,Wakai RT

    更新日期:2011-01-01 00:00:00

  • Comparison of EPR oximetry and Eppendorf polarographic electrode assessments of rat brain PtO2.

    abstract::EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other av...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/6/007

    authors: O'Hara JA,Khan N,Hou H,Wilmo CM,Demidenko E,Dunn JF,Swartz HM

    更新日期:2004-12-01 00:00:00

  • Multichannel simultaneous magnetic induction measurement system (MUSIMITOS).

    abstract::Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendab...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S25

    authors: Steffen M,Heimann K,Bernstein N,Leonhardt S

    更新日期:2008-06-01 00:00:00

  • Network proteomics of human dermal wound healing.

    abstract:OBJECTIVE:The healing of wounds is critical in protecting the human body against environmental factors. The mechanisms involving protein expression during this complex physiological process have not been fully elucidated. APPROACH:Here, we use reverse-phase protein microarrays (RPPA) involving 94 phosphoproteins to st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaee19

    authors: Gao X,Petricoin EF 3rd,Ward KR,Goldberg SR,Duane TM,Bonchev D,Arodz T,Diegelmann RF

    更新日期:2018-12-07 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise.

    abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/5/008

    authors: Wang L,Poon CC,Zhang YT

    更新日期:2010-05-01 00:00:00

  • Chasing the evidence: the influence of data segmentation on estimates of dynamic cerebral autoregulation.

    abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7ddf

    authors: Panerai RB,Intharakham K,Haunton V,Minhas JS,Llwyd O,Lam M,Salinet ASM,Nogueira RC,Katsogridakis E,Maggio P,Robinson TG

    更新日期:2020-04-17 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Comparison of self-reported measure of sitting time (IPAQ) with objective measurement (activPAL).

    abstract::This study compared sitting time measured by a questionnaire (International Physical Activity Questionnaire; IPAQ) with concurrently measured objective sitting time from an accelerometer-based measure of thigh inclination (activPAL).Adults (n = 69), wore an activPAL for a week, and then completed the long-form 7 d rec...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/11/2319

    authors: Chastin SF,Culhane B,Dall PM

    更新日期:2014-11-01 00:00:00

  • Multimodal heart beat detection using signal quality indices.

    abstract::The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure ca...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/8/1665

    authors: Johnson AE,Behar J,Andreotti F,Clifford GD,Oster J

    更新日期:2015-08-01 00:00:00

  • Dynamic data monitoring improves predictive analytics for failed extubation in the ICU.

    abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aace95

    authors: Keim-Malpass J,Enfield KB,Calland JF,Lake DE,Clark MT

    更新日期:2018-07-16 00:00:00

  • PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation.

    abstract::Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However,...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/2/231

    authors: Rasera CC,Gewehr PM,Domingues AM

    更新日期:2015-02-01 00:00:00

  • Head and pelvis stride-to-stride oscillations in gait: validation and interpretation of measurements from wearable accelerometers.

    abstract::Unstable gait is a risk factor for falls. Wearable accelerometers enable remote monitoring of daily walking. Here, new methods for measuring stride-to-stride oscillations are validated against optical motion capture, normative data determined, and dependency on walking speed investigated. Walks by 13 young people (mea...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/857

    authors: Brodie MA,Beijer TR,Canning CG,Lord SR

    更新日期:2015-05-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00

  • Fetal beat detection in abdominal ECG recordings: global and time adaptive approaches.

    abstract::We present a method for location of fetal QRS in maternal abdominal ECG recordings. This method's initial, global approach was proposed in the context of the 2013 PhysioNet/Computing in Cardiology Challenge where it was tested on the 447 four channel one-minute recordings.The first step is filtering to eliminate basel...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1699

    authors: Rodrigues R

    更新日期:2014-08-01 00:00:00

  • Variability in estimating shunt from single pulse oximetry measurements.

    abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/967

    authors: Karlen W,Petersen CL,Dumont GA,Ansermino JM

    更新日期:2015-05-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat.

    abstract::Easily applicable and inexpensive water-specific techniques to evaluate local oedema, swollen tissue problems and fluid retention in humans are not available. In the present investigation a recently constructed non-invasive device for a local measurement of changes in tissue water in human skin and subcutaneous fat (S...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/004

    authors: Nuutinen J,Ikäheimo R,Lahtinen T

    更新日期:2004-04-01 00:00:00

  • The effect of fracture and fracture fixation on ultrasonic velocity and attenuation.

    abstract::Measurement of the velocity of propagation and attenuation of ultrasound (200 kHz) is believed to be a useful non-invasive technique for assessing the mechanical properties of bone. A new method for the determination of ultrasound velocity and attenuation of longitudinal waves in cortical bone was used in vivo and in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/17/3/006

    authors: Saulgozis J,Pontaga I,Lowet G,Van der Perre G

    更新日期:1996-08-01 00:00:00

  • A comparison of methods for estimating left ventricular volumes from radionuclide ventriculography.

    abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/1/004

    authors: Thorley PJ,Sheard KL,Rees MR

    更新日期:1993-02-01 00:00:00

  • Aging in autonomic control by multifractal studies of cardiac interbeat intervals in the VLF band.

    abstract::The heart rate responds dynamically to various intrinsic and environmental stimuli. The autonomic nervous system is said to play a major role in this response. Multifractal analysis offers a novel method to assess the response of cardiac interbeat intervals. Twenty-four hour ECG recordings of RR interbeat intervals (o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/10/014

    authors: Makowiec D,Rynkiewicz A,Wdowczyk-Szulc J,Zarczyńska-Buchowiecka M,Gałaska R,Kryszewski S

    更新日期:2011-10-01 00:00:00

  • Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging.

    abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/12/2529

    authors: Long X,Yang J,Weysen T,Haakma R,Foussier J,Fonseca P,Aarts RM

    更新日期:2014-12-01 00:00:00

  • Development of a novel method for assessing balance: the quantitative posturography system.

    abstract::Balance is the ability to maintain equilibrium while sitting or standing. There are a number of different methods which are used to assess balance: technical methods such as sway magnetometry, ataxia meter and force platforms, and clinical methods such as the functional reach test, Berg balance test and fall risk inde...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/4/309

    authors: Browne J,O'Hare N

    更新日期:2000-11-01 00:00:00

  • Personalized automatic sleep staging with single-night data: a pilot study with Kullback-Leibler divergence regularization.

    abstract:OBJECTIVE:Brain waves vary between people. This work aims to improve automatic sleep staging for longitudinal sleep monitoring via personalization of algorithms based on individual characteristics extracted from sleep data recorded during the first night. APPROACH:As data from a single night are very small, thereby ma...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921e

    authors: Phan H,Mikkelsen K,Chén OY,Koch P,Mertins A,Kidmose P,De Vos M

    更新日期:2020-07-01 00:00:00

  • A measurement of pulmonary blood volume increase during systole in humans.

    abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/15/4/010

    authors: Nitzan M,Mahler Y,Schechter D,Yaffe S,Bocher M,Chisin R

    更新日期:1994-11-01 00:00:00

  • Reference intervals for the evoked tympanic membrane displacement measurement: a non-invasive measure of intracranial pressure.

    abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa1d3

    authors: Campbell-Bell CM,Birch AA,Vignali D,Bulters D,Marchbanks RJ

    更新日期:2018-01-31 00:00:00