Abstract:
:The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standard data set. In this study, the FEM is used to generate simulation data, which are used to investigate the non-linear behaviour of EIT, the space dependence of its PSF and its capability of resolving nearby objects. It is found that for the case of iterative backprojection (IterB), the full width half maximum (FWHM) values of single-object perturbations for central, intermediate and peripheral high-contrast objects are 27%, 18% and 14% of the imaging region diameter respectively. For the method based on singular value decomposition of the Geselowitz lead sensitivity matrix (GS-SVD), the FWHM is not space dependent and is 12% of the imaging region diameter. Conclusions obtained using single-object PSF studies must also be checked with double-object or more complex perturbations because EIT is non-linear. For example, the GS-SVD method fails to detect two widely separated objects unless the truncation level of SVD is carefully adjusted. With more truncation, however, the resolution of the method is worsened. Based on these and similar observations a set of simulation data, which is proposed for comparative evaluation of different EIT algorithms, is specified and explained in the conclusion section.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül Odoi
10.1088/0967-3334/16/3a/021subject
Has Abstractpub_date
1995-08-01 00:00:00pages
A227-36issue
3 Suppl Aeissn
0967-3334issn
1361-6579journal_volume
16pub_type
杂志文章abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2/002
更新日期:1994-05-01 00:00:00
abstract::Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when rec...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/32/10/002
更新日期:2011-10-01 00:00:00
abstract::Sleep-wake patterns are often significantly disturbed in critically ill patients. This disturbance is closely linked to secondary brain dysfunctions in these patients. Sedation not only impairs sleep quality in ICU patients but also has detrimental effects on short- and long-term outcome. In other contexts, light ther...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/37/9/R73
更新日期:2016-09-01 00:00:00
abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/9/N01
更新日期:2008-09-01 00:00:00
abstract::Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule in...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1197
更新日期:2014-07-01 00:00:00
abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/008
更新日期:2005-10-01 00:00:00
abstract::We used the finite element (FE) method to estimate the spatial sensitivity of a needle electrode for bioimpedance measurements. This current conducting needle with an insulated shaft was inserted in a saline solution and the current was measured at the neutral electrode. Model resistance and reactance were calculated ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/10/006
更新日期:2010-10-01 00:00:00
abstract::Muscle injuries in the lower limb are common among professional football players. Classification is made according to severity and is diagnosed with radiological assessment as: grade I (minor strain or minor injury), grade II (partial rupture, moderate injury) and grade III (complete rupture, severe injury). Tetrapola...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/1/27
更新日期:2015-01-01 00:00:00
abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/19/1/008
更新日期:1998-02-01 00:00:00
abstract::Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendab...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/6/S25
更新日期:2008-06-01 00:00:00
abstract::A multi-frequency electrical impedance tomography system for cardiopulmonary monitoring has been designed with specialized digital signal processors developed primarily for the telecommunications sector. The system consists of two modules: a scan-head and a base-station. The scan-head, located close to the patient's t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/6/S04
更新日期:2009-06-01 00:00:00
abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/3/L1
更新日期:2016-03-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/3/315
更新日期:2012-03-01 00:00:00
abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/2/004
更新日期:2006-02-01 00:00:00
abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/1/005
更新日期:2008-01-01 00:00:00
abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abc0b6
更新日期:2020-12-11 00:00:00
abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/6/1149
更新日期:2014-06-01 00:00:00
abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/1/007
更新日期:1997-02-01 00:00:00
abstract::Gated SPECT (GSPECT) was evaluated for the measurement of left ventricular ejection fraction (LVEF) by comparing with equilibrium gated radionuclide ventriculography (RNVG). A total of 99 subjects underwent GSPECT and RNVG imaging. All studies were acquired in list mode with GSPECT studies processed to give 16- and 8-...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/22/2/312
更新日期:2001-05-01 00:00:00
abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/5/N01
更新日期:2008-05-01 00:00:00
abstract::Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/6/1161
更新日期:2015-06-01 00:00:00
abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/9/008
更新日期:2010-09-01 00:00:00
abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9047
更新日期:2017-10-31 00:00:00
abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa749
更新日期:2018-03-23 00:00:00
abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/10/2027
更新日期:2015-10-01 00:00:00
abstract::Agitation is a significant problem in the intensive care unit (ICU), affecting 71% of sedated adult patients during 58% of ICU patient-days (Fraser and Riker 2001 NY Health-Syst. Pharm. 20 17-24). Subjective scale-based assessment methods are currently used to assess the level of patient agitation, but are limited in ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/25/4/020
更新日期:2004-08-01 00:00:00
abstract::Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However,...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/2/231
更新日期:2015-02-01 00:00:00
abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/23/1/304
更新日期:2002-02-01 00:00:00
abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab7ddf
更新日期:2020-04-17 00:00:00