Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

Abstract:

:The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective was to evaluate repetitiveness as well as to propose and evaluate a method for real time estimation of the reliability of individual C(out) investigations. Repeated investigations were performed on an experimental model simulating the CSF system, and on 14 patients with hydrocephalus. DeltaC(out), calculated as the 95% confidence interval of C(out), was introduced as an estimate of the reliability of individual C(out) investigations. On the model, no significant difference was found between DeltaC(out) and the actual C(out) variation in repeated investigations (p = 0.135). The correlation between the first and the second patient investigation was high (R = 0.99, p < 0.05), although there was a significant difference between the investigations (p < 0.05). The standard deviation of difference was 2.60 microl (s kPa)(-1). The repetitiveness of C(out) with the new apparatus was high, and DeltaC(out) reflected the reliability of each investigation. This feature has to be taken into account in every individual case, before making a decision or performing research based on measurements of C(out) in the future.

journal_name

Physiol Meas

authors

Andersson N,Malm J,Bäcklund T,Eklund A

doi

10.1088/0967-3334/26/6/022

subject

Has Abstract

pub_date

2005-12-01 00:00:00

pages

1137-48

issue

6

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(05)03299-5

journal_volume

26

pub_type

杂志文章
  • Storage effects on the Cole-Cole parameters of erythrocyte suspensions.

    abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/7/006

    authors: Sezdi M,Bayik M,Ulgen Y

    更新日期:2006-07-01 00:00:00

  • Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

    abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6d00

    authors: Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

    更新日期:2017-06-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.

    abstract::Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The exp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S19

    authors: Frerichs I,Schmitz G,Pulletz S,Schädler D,Zick G,Scholz J,Weiler N

    更新日期:2007-07-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Restoration of the electrocardiogram during mechanical cardiopulmonary resuscitation.

    abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9e53

    authors: Isasi I,Irusta U,Aramendi E,Idris AH,Sörnmo L

    更新日期:2020-11-06 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • Simultaneous measurement of force and respiratory profiles during chest physiotherapy in ventilated children.

    abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/9/004

    authors: Gregson RK,Stocks J,Petley GW,Shannon H,Warner JO,Jagannathan R,Main E

    更新日期:2007-09-01 00:00:00

  • Techniques for early detection of Alzheimer's disease using spontaneous EEG recordings.

    abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/4/001

    authors: Woon WL,Cichocki A,Vialatte F,Musha T

    更新日期:2007-04-01 00:00:00

  • Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

    abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2/002

    authors: Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

    更新日期:1994-05-01 00:00:00

  • Ischemic small intestine-in vivo versus ex vivo bioimpedance measurements.

    abstract:OBJECTIVE:Bioimpedance has been used to investigate changes in electrical parameters during ischemia in various tissues. The small intestine is a multi-layered structure, with several distinct tissue types, and ischemia related changes occur at different times in the different intestinal layers. When investigating how ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa67b7

    authors: Strand-Amundsen RJ,Reims HM,Tronstad C,Kalvøy H,Martinsen ØG,Høgetveit JO,Ruud TE,Tønnessen TI

    更新日期:2017-05-01 00:00:00

  • Effects of awareness and nociception on heart rate variability during general anaesthesia.

    abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/207

    authors: Huhle R,Burghardt M,Zaunseder S,Wessel N,Koch T,Malberg H,Heller AR

    更新日期:2012-02-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00

  • Machine learning for nocturnal mass diagnosis of atrial fibrillation in a population at risk of sleep-disordered breathing.

    abstract:OBJECTIVE:In this research, we introduce a new methodology for atrial fibrillation (AF) diagnosis during sleep in a large population sample at risk of sleep-disordered breathing. APPROACH:The approach leverages digital biomarkers and recent advances in machine learning (ML) for mass AF diagnosis from overnight-hours o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abb8bf

    authors: Chocron A,Efraim R,Mandel F,Rueschman M,Palmius N,Penzel T,Elbaz M,Behar JA

    更新日期:2020-11-06 00:00:00

  • A new method for measurement of gas exchange during anaesthesia using an extractable marker gas.

    abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/001

    authors: Peyton PJ,Robinson GJ,Terry D,Junor PA

    更新日期:2004-02-01 00:00:00

  • Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation.

    abstract:OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subs...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaeb2

    authors: Zhao Z,Wang W,Zhang Z,Xu M,Frerichs I,Wu J,Moeller K

    更新日期:2018-03-29 00:00:00

  • An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances.

    abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/008

    authors: Demidenko E

    更新日期:2011-09-01 00:00:00

  • Tracking boundary movement and exterior shape modelling in lung EIT imaging.

    abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1119

    authors: Biguri A,Grychtol B,Adler A,Soleimani M

    更新日期:2015-06-01 00:00:00

  • Dynamic time warping and machine learning for signal quality assessment of pulsatile signals.

    abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1491

    authors: Li Q,Clifford GD

    更新日期:2012-09-01 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • An abdominal wall simulator for testing suprapubic urinary catheters.

    abstract::Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/308

    authors: Coveney VA,Gröver D

    更新日期:2001-08-01 00:00:00

  • New electrohysterogram-based estimators of intrauterine pressure signal, tonus and contraction peak for non-invasive labor monitoring.

    abstract:BACKGROUND:Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab37db

    authors: Benalcazar-Parra C,Garcia-Casado J,Ye-Lin Y,Alberola-Rubio J,Lopez Á,Perales-Marin A,Prats-Boluda G

    更新日期:2019-09-03 00:00:00

  • Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy.

    abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/27/4/005

    authors: Turner AA,Lozano-Nieto A,Bouffard M

    更新日期:2006-04-01 00:00:00

  • The possible role of the vagal nervous system in the recovery of the blood pressure control after cardiac arrest: a porcine model study.

    abstract::Previous studies have proved that the baroreceptor reflex (baroreflex) control of heart rate can be used for stratification of post-infarction population and, in general, cardiovascular disease populations. Many methods have been proposed to estimate the so-called baroreflex sensitivity (BRS) expressed as ms mmhg-1. M...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/38/1/63

    authors: Lavanga M,Baselli G,Fumagalli F,Ristagno G,Ferrario M

    更新日期:2017-01-01 00:00:00

  • Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

    abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/009

    authors: Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

    更新日期:2005-04-01 00:00:00

  • Airway resistance estimation by best fit analysis in very premature infants.

    abstract::Plethysmographic measurement of airway resistance (R(aw)) has been determined by single-point analysis, usually at 50% of maximum inspiratory flow (MIF). Computer-assisted (best fit) analysis, however, allows R(aw) to be calculated by applying a regression line to any portion of the plethysmograph pressure-flow loop. ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/2/304

    authors: Thomas M,Greenough A,Blowes R,Rafferty GF,Calvert S,Marlow N,Peacock JL,Milner AD

    更新日期:2002-05-01 00:00:00

  • Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

    abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/597

    authors: Li JH,Tsai CY,Huang HM

    更新日期:2014-04-01 00:00:00

  • Combined electrocardiogram and photoplethysmogram measurements as an indicator of objective sleepiness.

    abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/8/001

    authors: Chua CP,McDarby G,Heneghan C

    更新日期:2008-08-01 00:00:00

  • Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms.

    abstract::The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V(1) reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF or...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/1/007

    authors: Alcaraz R,Hornero F,Rieta JJ

    更新日期:2011-01-01 00:00:00