Abstract:
:A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes clinically relevant phases of SiSt, the aim of this study was to determine the reliability of an automated approach for quantifying durations and angular velocities of trunk flexion and extension during repeated SiSt transitions using one BFS (DynaPort® Hybrid). Forty multimorbid geriatric patients aged 84.1 ± 6.6 years were included. Each patient participated in two test sessions with a 5 min rest period in between. Intra- and interrater reliability was assessed. Intraclass correlation coefficients (ICCs), absolute and relative standard measurement errors (SEMs, SEMs%) and minimal detectable changes (MDCs(95), MDCs(95)%) were calculated. ICCs were good to excellent for all variables in the total sample (0.80-0.94). The intraobserver group (50%) showed a higher number of excellent ICCs (≥.9) compared to the interobserver subgroup (10%). SEM% was low for all variables (6.9-12.7%). MDC(95)% ranged 19.2-34.4% and more variables ≤30% were found in the intra- (80%) compared to the inter-observer group (60%). Study results demonstrate that the BFS system provides a reliable analysis of SiSt phases in geriatric patients, and is a substantial improvement over the stopwatch approach used in clinical practice today.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Schwenk M,Gogulla S,Englert S,Czempik A,Hauer Kdoi
10.1088/0967-3334/33/11/1931subject
Has Abstractpub_date
2012-11-01 00:00:00pages
1931-46issue
11eissn
0967-3334issn
1361-6579journal_volume
33pub_type
杂志文章abstract::Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Dopp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/11/2003
更新日期:2016-11-01 00:00:00
abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/5/673
更新日期:2016-05-01 00:00:00
abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/2/003
更新日期:2005-04-01 00:00:00
abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/10/2027
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa1d3
更新日期:2018-01-31 00:00:00
abstract::The paper presents a method for adaptive decomposition of an electrical bio-impedance (BI) signal into two components: cardiac and respiratory. The decomposition of a BI signal is not a trivial process because of the non-stationarity of the signal components and overlapping of their harmonic spectra. An application sp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/6/S02
更新日期:2008-06-01 00:00:00
abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa56b1
更新日期:2017-03-01 00:00:00
abstract::A multi-frequency electrical impedance tomography system for cardiopulmonary monitoring has been designed with specialized digital signal processors developed primarily for the telecommunications sector. The system consists of two modules: a scan-head and a base-station. The scan-head, located close to the patient's t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/6/S04
更新日期:2009-06-01 00:00:00
abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/019
更新日期:2005-08-01 00:00:00
abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abcdf4
更新日期:2020-12-31 00:00:00
abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/9/1624
更新日期:2016-09-01 00:00:00
abstract::Thermal sweating manikins are used to analyse the heat and mass transfer phenomena in the skin-clothing-environment system. However, the limiting factor of present thermal manikins is their inability to simulate adequately the human thermal behaviour, which has a significant effect on the clothing microenvironment. A ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/2/002
更新日期:2008-02-01 00:00:00
abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/5/N01
更新日期:2008-05-01 00:00:00
abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab21af
更新日期:2019-07-01 00:00:00
abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab525c
更新日期:2019-12-02 00:00:00
abstract::This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvemen...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/26/3/R02
更新日期:2005-06-01 00:00:00
abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa749
更新日期:2018-03-23 00:00:00
abstract::Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/308
更新日期:2001-08-01 00:00:00
abstract::The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1349
更新日期:2014-07-01 00:00:00
abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/026
更新日期:1996-11-01 00:00:00
abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/37/3/418
更新日期:2016-03-01 00:00:00
abstract::EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other av...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/6/007
更新日期:2004-12-01 00:00:00
abstract::The left atrium (LA) plays an important role in the maintenance of hemodynamic and electrical stability of the heart. One of the conditions altering the atrial mechanical function is atrial fibrillation (AF), leading to an increased thromboembolic risk due to impaired mechanical function. Preserving the regions of the...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/5/763
更新日期:2014-05-01 00:00:00
abstract::We aim to investigate whether phase shift between respiratory oscillations in cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) is associated with changes in cerebral autoregulation (CA) or reflects the mechano-elastic properties of the cerebrovascular bed. The relationships between respiratory pha...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/38/2/310
更新日期:2017-02-01 00:00:00
abstract::The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure ca...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/8/1665
更新日期:2015-08-01 00:00:00
abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/318
更新日期:2001-08-01 00:00:00
abstract::Acupuncture (ACU) is known to be effective in ischemia treatment, and glutamate (GLU) excitotoxicity is an important factor in neuronal cell death. We observed the effect of ACU on cerebral blood flow (%CBF) and DeltaGLU (the changes in GLU release) in the ischemic stroke rat model of diabetic mellitus (DM). A global ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/5/003
更新日期:2010-05-01 00:00:00
abstract::One unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper presents an automatic approach to detect such erroneous electrodes. It is based on the assumption that all valid m...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/2/017
更新日期:2005-04-01 00:00:00
abstract::Brown adipose tissue (BAT) plays a key role in adaptive thermogenesis in mammals, and it has recently been considered as an attractive therapeutic target for tackling human obesity by increasing energy expenditure. Thermal imaging using infrared thermography (IRT) has emerged as a potential safe, rapid and inexpensive...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/12/N118
更新日期:2016-12-01 00:00:00
abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/9/008
更新日期:2011-09-01 00:00:00