Abstract:
OBJECTIVE:The ratio of the partial pressure of arterial oxygen to fraction of inspired oxygen is a key component of the sequential organ failure assessment score that operationally defines sepsis. But, it is calculated infrequently due to the need for the acquisition of an arterial blood gas. So, we sought to find an optimal imputation strategy for the estimation of sepsis-defining hypoxemic respiratory failure using oximetry instead of an arterial blood gas. APPROACH:We retrospectively studied a sample of non-intubated acute-care patients with oxygen saturation recorded ⩽10 min before arterial blood sampling (N = 492 from 2013-2017). We imputed ratios of the partial pressure of arterial oxygen to the fraction of inspired oxygen and sepsis criteria from existing imputation equations (Hill, Severinghaus-Ellis, Rice, and Pandharipande) and compared them with the ratios and sepsis criteria measured from arterial blood gases. We devised a modified model-based equation to eliminate the bias of the results. MAIN RESULTS:Hypoxemia severity estimates from the Severinghaus-Ellis equation were more accurate than those from other existing equations, but showed significant proportional bias towards under-estimation of hypoxemia severity, especially at oxygen saturations >96%. Our modified equation eliminated bias and surpassed others on all imputation quality metrics. SIGNIFICANCE:Our modified imputation equation, [Formula: see text] is the first one that is free of bias at all oxygen saturations. It resulted in ratios of partial pressure of arterial oxygen to fraction of inspired oxygen and sepsis respiratory criteria closest to those obtained by arterial blood gas testing and is the optimal imputation strategy for non-intubated acute-care patients.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Gadrey SM,Lau CE,Clay R,Rhodes GT,Lake DE,Moore CC,Voss JD,Moorman JRdoi
10.1088/1361-6579/ab5154subject
Has Abstractpub_date
2019-12-03 00:00:00pages
115008issue
11eissn
0967-3334issn
1361-6579journal_volume
40pub_type
杂志文章abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa74d
更新日期:2018-02-28 00:00:00
abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/1/004
更新日期:1993-02-01 00:00:00
abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/N61
更新日期:2015-03-01 00:00:00
abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/14/4a/014
更新日期:1993-11-01 00:00:00
abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/5/N01
更新日期:2008-05-01 00:00:00
abstract:OBJECTIVE:As the global burden of cardiovascular disease increases, proactive cardiovascular healthcare by means of accurate, precise, continuous, and non-invasive monitoring is becoming crucial. However, no current device is able to provide cardiac hemodynamic monitoring with the aforementioned criterion. Electrical i...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abb141
更新日期:2020-10-06 00:00:00
abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/006
更新日期:1996-11-01 00:00:00
abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/1/004
更新日期:1994-02-01 00:00:00
abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/5/807
更新日期:2014-05-01 00:00:00
abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/10/002
更新日期:2009-10-01 00:00:00
abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/019
更新日期:2005-08-01 00:00:00
abstract::The objective of this study was to adapt a novel near-infrared diffuse correlation spectroscopy (DCS) flow-oximeter for simultaneous and continuous monitoring of relative changes in cerebral blood flow (rCBF) and cerebral oxygenation (i.e. oxygenated/deoxygenated/total hemoglobin concentration: Δ[HbO2]/Δ[Hb]/ΔTHC) dur...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/10/2135
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/1361-6579/aab2ef
更新日期:2018-04-20 00:00:00
abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9e53
更新日期:2020-11-06 00:00:00
abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/2/223
更新日期:2013-02-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba6a1
更新日期:2021-01-01 00:00:00
abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/29/6/S29
更新日期:2008-06-01 00:00:00
abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab840b
更新日期:2020-05-07 00:00:00
abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/3a/012
更新日期:1995-08-01 00:00:00
abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/4/544
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9047
更新日期:2017-10-31 00:00:00
abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/6/659
更新日期:2013-06-01 00:00:00
abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/25/5/015
更新日期:2004-10-01 00:00:00
abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1491
更新日期:2012-09-01 00:00:00
abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/011
更新日期:2004-02-01 00:00:00
abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/1/308
更新日期:2003-02-01 00:00:00
abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/3/002
更新日期:2007-03-01 00:00:00
abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/10/S02
更新日期:2010-10-01 00:00:00
abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/001
更新日期:1994-05-01 00:00:00
abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/4/597
更新日期:2014-04-01 00:00:00