Fractal analysis of foetal heart rate variability.

Abstract:

:Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dimensions in FHR variation. An irregular line was plotted from 2500 consecutive foetal heart beat to beat intervals derived from an ultrasound source. A window of 500 intervals was moved along the line in steps of 20 intervals. At each step the Richardson technique was used to make estimates of the length of the line within the window using 40 different ruler lengths. When the estimates were plotted against the ruler lengths on log-log axes the resulting curve exhibited two distinct linear regions, each demonstrating an inverse power relationship. From the two slopes the fractal dimensions were derived for unspecified low- and high-frequency FHR variation in the current window. The values of both fractal dimensions were plotted simultaneously with the irregular FHR line and were found to accord with perceived changes in FHR variation. The method described is simply a measure of the irregularity in a series of foetal heart beat to beat intervals: the existence of fractal properties in the irregular line does not of itself imply underlying deterministic dynamics (e.g. chaos). This new method of observing FHR variability requires no preprocessing of the measured data, which are all taken into account. Not only does it represent a method for studying normal foetal behaviour but also has potential as a sensitive indicator of impending foetal compromise.

journal_name

Physiol Meas

authors

Gough NA

doi

10.1088/0967-3334/14/3/009

subject

Has Abstract

pub_date

1993-08-01 00:00:00

pages

309-15

issue

3

eissn

0967-3334

issn

1361-6579

journal_volume

14

pub_type

杂志文章
  • Video and audio processing in paediatrics: a review.

    abstract:OBJECTIVE:Video and sound acquisition and processing technologies have seen great improvements in recent decades, with many applications in the biomedical area. The aim of this paper is to review the overall state of the art of advances within these topics in paediatrics and to evaluate their potential application for ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab0096

    authors: Cabon S,Porée F,Simon A,Rosec O,Pladys P,Carrault G

    更新日期:2019-02-26 00:00:00

  • Localization of sources of brain alpha/theta/delta activity and the influence of the mode of spontaneous mentation.

    abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4a/004

    authors: Michel CM,Henggeler B,Brandeis D,Lehmann D

    更新日期:1993-11-01 00:00:00

  • A method of reducing the error caused by boundary shape and electrode positions in electrical impedance tomography.

    abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/022

    authors: Li J

    更新日期:1994-05-01 00:00:00

  • Length and activation dependent variations in muscle shear wave speed.

    abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/34/6/713

    authors: Chernak LA,DeWall RJ,Lee KS,Thelen DG

    更新日期:2013-06-01 00:00:00

  • Microfluidics for flow cytometric analysis of cells and particles.

    abstract::This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvemen...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/26/3/R02

    authors: Huh D,Gu W,Kamotani Y,Grotberg JB,Takayama S

    更新日期:2005-06-01 00:00:00

  • Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography.

    abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/030

    authors: Park C,Park EJ,Woo EJ,Kwon O,Seo JK

    更新日期:2004-02-01 00:00:00

  • Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation.

    abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/4/010

    authors: Hren R,Horácek BM

    更新日期:1997-11-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.

    abstract::Electrocardiograms (ECGs) recorded from patients in intensive care were investigated to quantify any relationship between ECG signal quality and false monitoring alarms. False alarms are a considerable problem for nursing and medical staff as they distract from clinical care, and are also a problem for patients as the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1383

    authors: Tsimenidis C,Murray A

    更新日期:2016-08-01 00:00:00

  • Tracking time-varying cerebral autoregulation in response to changes in respiratory PaCO2.

    abstract::Cerebral autoregulation has been studied by linear filter systems, with arterial blood pressure (ABP) as the input and cerebral blood flow velocity (CBFV-from transcranial Doppler Ultrasound) as the output. The current work extends this by using adaptive filters to investigate the dynamics of time-varying cerebral aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/001

    authors: Liu J,Simpson MD,Yan J,Allen R

    更新日期:2010-10-01 00:00:00

  • Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.

    abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/3/L1

    authors: Anagnostopoulou P,Egger B,Lurà M,Usemann J,Schmidt A,Gorlanova O,Korten I,Roos M,Frey U,Latzin P

    更新日期:2016-03-01 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00

  • Simultaneous measurement of force and respiratory profiles during chest physiotherapy in ventilated children.

    abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/9/004

    authors: Gregson RK,Stocks J,Petley GW,Shannon H,Warner JO,Jagannathan R,Main E

    更新日期:2007-09-01 00:00:00

  • Cooperative dry-electrode sensors for multi-lead biopotential and bioimpedance monitoring.

    abstract::Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a mu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/4/767

    authors: Rapin M,Proença M,Braun F,Meier C,Solà J,Ferrario D,Grossenbacher O,Porchet JA,Chételat O

    更新日期:2015-04-01 00:00:00

  • Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data.

    abstract::Despite significant advances in adult clinical electrocardiography (ECG) signal processing techniques and the power of digital processors, the analysis of non-invasive foetal ECG (NI-FECG) is still in its infancy. The Physionet/Computing in Cardiology Challenge 2013 addresses some of these limitations by making a set ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1569

    authors: Behar J,Oster J,Clifford GD

    更新日期:2014-08-01 00:00:00

  • Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1435

    authors: Di Marco LY,Duan W,Bojarnejad M,Zheng D,King S,Murray A,Langley P

    更新日期:2012-09-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

    abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/022

    authors: Andersson N,Malm J,Bäcklund T,Eklund A

    更新日期:2005-12-01 00:00:00

  • Masticatory muscle activity during deliberately performed oral tasks.

    abstract::The aim of this study was to investigate masticatory muscle activity during deliberately performed functional and non-functional oral tasks. Electromyographic (EMG) surface activity was recorded unilaterally from the masseter, anterior temporalis and suprahyoid muscles in 11 subjects (5 men, 6 women; age = 34.6 +/- 10...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/12/004

    authors: Farella M,Palla S,Erni S,Michelotti A,Gallo LM

    更新日期:2008-12-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00

  • Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

    abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/009

    authors: Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

    更新日期:2005-04-01 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Non-contact video-based vital sign monitoring using ambient light and auto-regressive models.

    abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/5/807

    authors: Tarassenko L,Villarroel M,Guazzi A,Jorge J,Clifton DA,Pugh C

    更新日期:2014-05-01 00:00:00

  • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry.

    abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/3/008

    authors: Steel SA,Swann P,Langley G,Langton CM

    更新日期:1997-08-01 00:00:00

  • Infrared thermography for indirect assessment of activation of brown adipose tissue in lean and obese male subjects.

    abstract::Brown adipose tissue (BAT) plays a key role in adaptive thermogenesis in mammals, and it has recently been considered as an attractive therapeutic target for tackling human obesity by increasing energy expenditure. Thermal imaging using infrared thermography (IRT) has emerged as a potential safe, rapid and inexpensive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/12/N118

    authors: El Hadi H,Frascati A,Granzotto M,Silvestrin V,Ferlini E,Vettor R,Rossato M

    更新日期:2016-12-01 00:00:00

  • Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1035

    authors: Grychtol B,Adler A

    更新日期:2014-06-01 00:00:00

  • Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy.

    abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/27/4/005

    authors: Turner AA,Lozano-Nieto A,Bouffard M

    更新日期:2006-04-01 00:00:00

  • Independent component analysis of normal and abnormal rhythm in twin pregnancies.

    abstract::We investigated the utility of ICA for evaluation of fetal rhythm in five uncomplicated twin pregnancies and in five twin pregnancies complicated by fetal arrhythmia. Using objective and subjective criteria, we sought to determine how the signal-to-noise ratio, signal fidelity and interference rejection are affected w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/1/004

    authors: Mensah-Brown NA,Lutter WJ,Comani S,Strasburger JF,Wakai RT

    更新日期:2011-01-01 00:00:00

  • The effect of serial data collection on the accuracy of electrical impedance tomography images.

    abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/6/659

    authors: Yerworth R,Bayford R

    更新日期:2013-06-01 00:00:00

  • Electrical impedance myography at frequencies up to 2 MHz.

    abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/29/6/S29

    authors: Shiffman CA,Kashuri H,Aaron R

    更新日期:2008-06-01 00:00:00

  • Characteristic impedance: frequency or time domain approach?

    abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9d60

    authors: Qureshi MU,Colebank MJ,Schreier DA,Tabima DM,Haider MA,Chesler NC,Olufsen MS

    更新日期:2018-01-31 00:00:00