Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

Abstract:

OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review assesses the prevalence of current saccade detection algorithms, their associated validation methodologies and the suitability of their application. Medline, Embase, PsychInfo, Scopus, IEEEXplore and ACM Digital Library databases were searched. Two independent reviewers and an adjudicator screened articles describing the detection of saccades from raw infrared/video-based eye-tracker data. MAIN RESULTS:Thirteen articles were screened and met the inclusion criteria. Overall, the majority of reviewed saccadic detection algorithms used simple velocity-based classifications with static eye-tracking systems. Studies demonstrated validity but are limited by the static nature of testing. Heterogeneity in system design, proprietary and bespoke algorithmic methods used, processing strategies, and outcome reporting is evident. SIGNIFICANCE:This paper suggests the use of a more standardised methodology to facilitate experimental validity and improve comparison of results across studies.

journal_name

Physiol Meas

authors

Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

doi

10.1088/1361-6579/ab02ab

subject

Has Abstract

pub_date

2019-02-26 00:00:00

pages

02TR01

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

40

pub_type

杂志文章,评审
  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00

  • Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration.

    abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab21af

    authors: Lucas BP,D'Addio A,Block C,Manning H,Remillard B,Leiter JC

    更新日期:2019-07-01 00:00:00

  • The contribution of vascular smooth muscle, elastin and collagen on the passive mechanics of porcine carotid arteries.

    abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/8/1335

    authors: Kochová P,Kuncová J,Svíglerová J,Cimrman R,Miklíková M,Liška V,Tonar Z

    更新日期:2012-08-01 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements.

    abstract::Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/4/006

    authors: Panerai RB,Sammons EL,Smith SM,Rathbone WE,Bentley S,Potter JF,Samani NJ

    更新日期:2008-04-01 00:00:00

  • The effect of serial data collection on the accuracy of electrical impedance tomography images.

    abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/6/659

    authors: Yerworth R,Bayford R

    更新日期:2013-06-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Quantitative description of the 3D regional mechanics of the left atrium using cardiac magnetic resonance imaging.

    abstract::The left atrium (LA) plays an important role in the maintenance of hemodynamic and electrical stability of the heart. One of the conditions altering the atrial mechanical function is atrial fibrillation (AF), leading to an increased thromboembolic risk due to impaired mechanical function. Preserving the regions of the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/5/763

    authors: Kuklik P,Molaee P,Podziemski P,Ganesan AN,Brooks AG,Worthley SG,Sanders P

    更新日期:2014-05-01 00:00:00

  • Combined electrocardiogram and photoplethysmogram measurements as an indicator of objective sleepiness.

    abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/8/001

    authors: Chua CP,McDarby G,Heneghan C

    更新日期:2008-08-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

    abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/009

    authors: Boone KG,Holder DS

    更新日期:1995-08-01 00:00:00

  • The effect of fracture and fracture fixation on ultrasonic velocity and attenuation.

    abstract::Measurement of the velocity of propagation and attenuation of ultrasound (200 kHz) is believed to be a useful non-invasive technique for assessing the mechanical properties of bone. A new method for the determination of ultrasound velocity and attenuation of longitudinal waves in cortical bone was used in vivo and in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/17/3/006

    authors: Saulgozis J,Pontaga I,Lowet G,Van der Perre G

    更新日期:1996-08-01 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • Magnetographic assessment of fetal hiccups and their effect on fetal heart rhythm.

    abstract::Fetal hiccups emerge as early as nine weeks post-conception, being the predominant diaphragmatic movement before 26 weeks of gestation. They are considered as a programmed isometric inspiratory muscle exercise of the fetus in preparation for the post-natal respiratory function, or a manifestation of a reflex circuitry...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/6/005

    authors: Popescu EA,Popescu M,Bennett TL,Lewine JD,Drake WB,Gustafson KM

    更新日期:2007-06-01 00:00:00

  • EIT data noise evaluation in the clinical environment.

    abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/006

    authors: Meeson S,Blott BH,Killingback AL

    更新日期:1996-11-01 00:00:00

  • Circuit modeling of the electrical impedance: II. Normal subjects and system reproducibility.

    abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/2/223

    authors: Shiffman CA,Rutkove SB

    更新日期:2013-02-01 00:00:00

  • Measurement of pupil reactivity using fast pupillometry.

    abstract::Analysis of human eye pupil reactivity is a very valuable diagnostic method used mainly for evaluation of the condition of the autonomic nervous system and the visual system. The paper presents an experimental pupillometer built in the Institute of Physics of the Wroclaw University of Technology. The apparatus makes i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/1/006

    authors: Hachol A,Szczepanowska-Nowak W,Kasprzak H,Zawojska I,Dudzinski A,Kinasz R,Wygledowska-Promienska D

    更新日期:2007-01-01 00:00:00

  • Real time impedance plots with arbitrary frequency components.

    abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/1/008

    authors: Searle A,Kirkup L

    更新日期:1999-02-01 00:00:00

  • Modelling the electrical properties of bladder tissue--quantifying impedance changes due to inflammation and oedema.

    abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/3/010

    authors: Walker DC,Smallwood RH,Keshtar A,Wilkinson BA,Hamdy FC,Lee JA

    更新日期:2005-06-01 00:00:00

  • False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.

    abstract::Electrocardiograms (ECGs) recorded from patients in intensive care were investigated to quantify any relationship between ECG signal quality and false monitoring alarms. False alarms are a considerable problem for nursing and medical staff as they distract from clinical care, and are also a problem for patients as the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1383

    authors: Tsimenidis C,Murray A

    更新日期:2016-08-01 00:00:00

  • Novel technology to help understand the context of physical activity and sedentary behaviour.

    abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1834

    authors: Loveday A,Sherar LB,Sanders JP,Sanderson PW,Esliger DW

    更新日期:2016-10-01 00:00:00

  • Non-invasive measurements of respiratory system mechanical properties by the forced oscillation technique in spontaneously breathing, mixed-breed, normal term lambs from birth to five months of age.

    abstract:OBJECTIVE:To provide a non-invasive approach to monitoring lung function in spontaneously breathing lambs, from birth to five months of life, by the forced oscillation technique (FOT). This report describes the experimental set-up, data processing, and identification of normal predicted values of resistance (Rrs) and r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab3493

    authors: Veneroni C,Dahl MJ,Lavizzari A,Dawson E,Rebentisch A,Studstill S,Bowen S,Albertine KH,Dellaca RL

    更新日期:2019-11-04 00:00:00

  • Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/1163

    authors: Riknagel D,Dinesen B,Zimmermann H,Farlie R,Schmidt S,Toft E,Struijk JJ

    更新日期:2016-07-01 00:00:00

  • Time-related heart autonomic balance characteristics in healthy subjects.

    abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/3/309

    authors: Matveev M,Prokopova R,Nachev Ch

    更新日期:2003-08-01 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/9/1624

    authors: Gade J,Greisen G

    更新日期:2016-09-01 00:00:00

  • The measurement of sedentary patterns and behaviors using the activPAL™ Professional physical activity monitor.

    abstract::Epidemiological studies have associated the negative effects of sedentary time and sedentary patterns on health indices. However, these studies have used methodologies that do not directly measure the sedentary state. Recent technological developments in the area of motion sensors have incorporated inclinometers, whic...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/11/1887

    authors: Dowd KP,Harrington DM,Bourke AK,Nelson J,Donnelly AE

    更新日期:2012-11-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • The physiological impact of the nonlinearity of arterial elasticity in the ambulatory arterial stiffness index.

    abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/7/012

    authors: Craiem D,Graf S,Salvucci F,Chironi G,Megnien JL,Simon A,Armentano RL

    更新日期:2010-07-01 00:00:00