Abstract:
:In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performance with a known standard, or with previous studies, can be generated. The method depends on calculating the variances of the differences in reciprocity measurements as a function of the distance between the current drive electrodes and the receive voltage electrodes. These measurements fit the noise model, with minimal interference from physiological variability, and permit a figure of merit to be calculated which is a representation of the noise at the point to the system. Typical figures of merit are 7.36 +/- 0.03 microV for a test card and 10.50 +/- 16 microV for subject data.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Meeson S,Blott BH,Killingback ALdoi
10.1088/0967-3334/17/4a/006subject
Has Abstractpub_date
1996-11-01 00:00:00pages
A33-8eissn
0967-3334issn
1361-6579journal_volume
17 Suppl 4Apub_type
杂志文章abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aace95
更新日期:2018-07-16 00:00:00
abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/008
更新日期:2005-10-01 00:00:00
abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S10
更新日期:2011-07-01 00:00:00
abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/2/223
更新日期:2013-02-01 00:00:00
abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/1/004
更新日期:1993-02-01 00:00:00
abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/5/S05
更新日期:2006-05-01 00:00:00
abstract::Health is one of the most important non-material assets and thus also has an enormous influence on material values, since treating and preventing diseases is expensive. The number one cause of death worldwide today originates in cardiovascular diseases. For these reasons the aim of understanding the functions and the ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/37/5/R46
更新日期:2016-05-01 00:00:00
abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/4/309
更新日期:2002-11-01 00:00:00
abstract::Monitoring the brain state in anaesthesia is crucial for clinical doctors. In this study, we propose a novel nonlinear method, the permutation Lempel-Ziv complexity (PLZC) index, which describes the complexity in the electroencephalographic (EEG) signal to quantify the effect of GABAergic anaesthetics on brain activit...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/12/2483
更新日期:2015-12-01 00:00:00
abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/3/002
更新日期:2007-03-01 00:00:00
abstract::Electrical impedance endotomography (EIE) is a modality of impedance imaging where the electrodes are located on an insulating core placed at the centre of the region of interest. The absence of a physical limit to the medium surrounding the probe enables the use of remote electrodes. The present study compares the fe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/001
更新日期:2005-08-01 00:00:00
abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/8/001
更新日期:2008-08-01 00:00:00
abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/32/4/008
更新日期:2011-04-01 00:00:00
abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/4/007
更新日期:1993-11-01 00:00:00
abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/318
更新日期:2001-08-01 00:00:00
abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/4/003
更新日期:1995-11-01 00:00:00
abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1785
更新日期:2016-10-01 00:00:00
abstract::Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/001
更新日期:2007-05-01 00:00:00
abstract:OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abdf3d
更新日期:2021-01-22 00:00:00
abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/34/6/713
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVE:Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals' short biologic half-lives, shipping and storage requirement...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aad947
更新日期:2018-08-31 00:00:00
abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba6a1
更新日期:2021-01-01 00:00:00
abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/23/1/304
更新日期:2002-02-01 00:00:00
abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab02ab
更新日期:2019-02-26 00:00:00
abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/31/6/007
更新日期:2010-06-01 00:00:00
abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/7/008
更新日期:2008-07-01 00:00:00
abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/11/1483
更新日期:2013-11-01 00:00:00
abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/8/006
更新日期:2006-08-01 00:00:00
abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/4a/004
更新日期:1993-11-01 00:00:00
abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab921d
更新日期:2020-06-30 00:00:00