Abstract:
:Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to which reliability may be affected by the position of the subjects is also unclear. Therefore, we conducted an analysis of the intra- and inter-session reliability of two methods of assessing passive knee extension: (A) a 2D kinematic analysis coupled to a custom-made device that enabled the direct measurement of resistance to stretch and (B) an isokinetic dynamometer used in two testing positions (with the non-tested thigh either flexed at 45° or in the neutral position). The intra-class correlation coefficients (ICCs) of torque, the slope of the torque-angle curve, and the parameters of the mathematical model that were fit to the torque-angle data for the above conditions were measured in sixteen healthy male subjects (age: 21.4 ± 2.1 yr; BMI: 22.6 ± 3.3 kg m(-2); tibial length: 37.4 ± 3.4 cm). The results found were: (1) methods A and B led to distinctly different torque-angle responses; (2) passive torque-angle relationship and stretch tolerance were influenced by the position of the non-tested thigh; and (3) ICCs obtained for torque were higher than for the slope and for the mathematical parameters that were fit to the torque-angle curve. In conclusion, the measurement method that is used and the positioning of subjects can influence the passive knee extension torque-angle outcome.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Freitas SR,Vaz JR,Bruno PM,Valamatos MJ,Mil-Homens Pdoi
10.1088/0967-3334/34/11/1483subject
Has Abstractpub_date
2013-11-01 00:00:00pages
1483-98issue
11eissn
0967-3334issn
1361-6579journal_volume
34pub_type
杂志文章abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/1/83
更新日期:2016-01-01 00:00:00
abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/4/010
更新日期:1997-11-01 00:00:00
abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...
journal_title:Physiological measurement
pub_type: 历史文章,杂志文章,评审
doi:10.1088/0967-3334/31/1/R01
更新日期:2010-01-01 00:00:00
abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abcdf4
更新日期:2020-12-31 00:00:00
abstract::Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almos...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/33/2/243
更新日期:2012-02-01 00:00:00
abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/2/223
更新日期:2013-02-01 00:00:00
abstract:OBJECTIVE:Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cogn...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab979e
更新日期:2020-07-07 00:00:00
abstract:OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abdf3d
更新日期:2021-01-22 00:00:00
abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/1/308
更新日期:2003-02-01 00:00:00
abstract::Accelerometer wear location may influence physical activity estimates. This study investigates this relationship through the examination of activity patterns throughout the day. Participants from the aging research evaluating accelerometry (AREA) study (n men = 37, n women = 47, mean age (SD) = 78.9 (5.5) years)...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1852
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab0daa
更新日期:2019-04-03 00:00:00
abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/3/010
更新日期:2005-06-01 00:00:00
abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/3/006
更新日期:2008-03-01 00:00:00
abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/9/004
更新日期:2007-09-01 00:00:00
abstract::The objective of this study was to adapt a novel near-infrared diffuse correlation spectroscopy (DCS) flow-oximeter for simultaneous and continuous monitoring of relative changes in cerebral blood flow (rCBF) and cerebral oxygenation (i.e. oxygenated/deoxygenated/total hemoglobin concentration: Δ[HbO2]/Δ[Hb]/ΔTHC) dur...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/10/2135
更新日期:2014-10-01 00:00:00
abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/23/1/304
更新日期:2002-02-01 00:00:00
abstract:OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The internati...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa455
更新日期:2018-02-26 00:00:00
abstract::Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/308
更新日期:2001-08-01 00:00:00
abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9d60
更新日期:2018-01-31 00:00:00
abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/2/367
更新日期:2003-05-01 00:00:00
abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/1/31
更新日期:2014-01-01 00:00:00
abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/37/3/418
更新日期:2016-03-01 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00
abstract::Muscle injuries in the lower limb are common among professional football players. Classification is made according to severity and is diagnosed with radiological assessment as: grade I (minor strain or minor injury), grade II (partial rupture, moderate injury) and grade III (complete rupture, severe injury). Tetrapola...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/1/27
更新日期:2015-01-01 00:00:00
abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/301
更新日期:2001-02-01 00:00:00
abstract::Objective assessment of stroke-patients' ability to control arm movements is vital for evidence-based therapy and progress monitoring. This study compares three different indices to quantify the quality of wrist movement during a task involving tracking a target on a screen. Each method is assessed in terms of agreeme...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/8/011
更新日期:2007-08-01 00:00:00
abstract::Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system u...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/465
更新日期:2015-03-01 00:00:00
abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/15/4/010
更新日期:1994-11-01 00:00:00
abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/3a/021
更新日期:1995-08-01 00:00:00
abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/3a/012
更新日期:1995-08-01 00:00:00