The influence of dilution on the offline measurement of exhaled nitric oxide.

Abstract:

OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The international guidelines for offline measurements recommend collection of exhaled gas in an appropriate reservoir for later analysis in young children. The apparatus required for gas collection, however, creates dead space within the system, which may result in sample dilution and hence inaccuracy. Our objective was to investigate the effect such dilution might have on the accuracy of offline FeNO by comparing the results to online results. APPROACH:Thirty-five adult subjects without respiratory disease underwent online measurement of FeNO and, thereafter, undertook offline FeNO measurements via exhalation into a collection reservoir using one, five or ten inhalation-exhalation cycles. Fifteen of the subjects also exhaled using the five-breath technique via apparatus with additional dead space. An equation incorporating dead space volume and the number of breaths was used to predict the degree of dilution; the predicted results were compared to the measured results. MAIN RESULTS:The median (IQR) FeNO from a one-breath technique (22 (15-28) ppb was not significantly different to online values (19 (12-27) ppb, p  =  1.00), but the results from the five-breath technique (11 (4-19) ppb, p  <  0.0001), the ten-breath technique (6 (4-15) ppb, p  <  0.0001) and the additional dead space experiment (6 (3-8) ppb, p  =  0.0006) were significantly lower than online FeNO. Measured values were consistently significantly different to those predicted by the dilution equation, even when incorporating the exact exhaled volume of gas. SIGNIFICANCE:Offline FeNO results may be inaccurate when subjects are unable to fill the collection reservoir with a single exhalation, thus the technique may not be suitable for preschool children.

journal_name

Physiol Meas

authors

MacBean V,Pooranampillai D,Howard C,Lunt A,Greenough A

doi

10.1088/1361-6579/aaa455

subject

Has Abstract

pub_date

2018-02-26 00:00:00

pages

025004

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

39

pub_type

杂志文章
  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00

  • The effect of serial data collection on the accuracy of electrical impedance tomography images.

    abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/6/659

    authors: Yerworth R,Bayford R

    更新日期:2013-06-01 00:00:00

  • Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

    abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/4/N01

    authors: Dellacà RL,Gobbi A,Pastena M,Pedotti A,Celli B

    更新日期:2010-04-01 00:00:00

  • Chasing the evidence: the influence of data segmentation on estimates of dynamic cerebral autoregulation.

    abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7ddf

    authors: Panerai RB,Intharakham K,Haunton V,Minhas JS,Llwyd O,Lam M,Salinet ASM,Nogueira RC,Katsogridakis E,Maggio P,Robinson TG

    更新日期:2020-04-17 00:00:00

  • An optimized lead system for long-term esophageal electrocardiography.

    abstract::Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/517

    authors: Niederhauser T,Haeberlin A,Marisa T,Mattle D,Abächerli R,Goette J,Jacomet M,Vogel R

    更新日期:2014-04-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in rats.

    abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/2/004

    authors: Hsiu H,Jan MY,Wang WK,Wang YY

    更新日期:2006-02-01 00:00:00

  • A method for modelling and optimizing an electrical impedance tomography system.

    abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/5/S05

    authors: Hartinger AE,Gagnon H,Guardo R

    更新日期:2006-05-01 00:00:00

  • The effect of ambient air temperature on whole-body bioelectrical impedance.

    abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/011

    authors: Buono MJ,Burke S,Endemann S,Graham H,Gressard C,Griswold L,Michalewicz B

    更新日期:2004-02-01 00:00:00

  • Recognition of elementary arm movements using orientation of a tri-axial accelerometer located near the wrist.

    abstract::In this paper we present a method for recognising three fundamental movements of the human arm (reach and retrieve, lift cup to mouth, rotation of the arm) by determining the orientation of a tri-axial accelerometer located near the wrist. Our objective is to detect the occurrence of such movements performed with the ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/9/1751

    authors: Biswas D,Corda D,Baldus G,Cranny A,Maharatna K,Achner J,Klemke J,Jöbges M,Ortmann S

    更新日期:2014-09-01 00:00:00

  • A wireless platform for in vivo measurement of resistance properties of the gastrointestinal tract.

    abstract::Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule in...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1197

    authors: Natali CD,Beccani M,Obstein KL,Valdastri P

    更新日期:2014-07-01 00:00:00

  • Empirical estimators of gamma fits to tracer-dilution curves and their technical basis and practical scope.

    abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/4/401

    authors: Lopatatzidis A,Millard RK

    更新日期:2001-11-01 00:00:00

  • Performance measurements of an infrared digital scanning laser ophthalmoscope.

    abstract::Direct digital acquisition of images using a scanning laser ophthalmoscope (SLO) offers several advantages over the conventional fundus camera; in particular, the ability to produce tomographic images using a confocal aperture. This note describes measurements of the performance of an SLO. Spatial resolution, measured...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/3/010

    authors: Manivannan A,Sharp PF,Forrester JV

    更新日期:1994-08-01 00:00:00

  • Patient examinations using electrical impedance tomography--sources of interference in the intensive care unit.

    abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/F01

    authors: Frerichs I,Pulletz S,Elke G,Gawelczyk B,Frerichs A,Weiler N

    更新日期:2011-12-01 00:00:00

  • Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

    abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/009

    authors: Boone KG,Holder DS

    更新日期:1995-08-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Compressive sensing in electrical impedance tomography for breathing monitoring.

    abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab0daa

    authors: Shiraz A,Khodadad D,Nordebo S,Yerworth R,Frerichs I,van Kaam A,Kallio M,Papadouri T,Bayford R,Demosthenous A

    更新日期:2019-04-03 00:00:00

  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • In vivo neutron activation analysis of bone manganese in workers.

    abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa749

    authors: Liu Y,Rolle-McFarland D,Mostafaei F,Zhou Y,Li Y,Zheng W,Wells E,Nie LH

    更新日期:2018-03-23 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Classification of glucose concentration in diluted urine using the low-resolution Raman spectroscopy and kernel optimization methods.

    abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/5/011

    authors: Park C,Kim K,Choi J,Park K

    更新日期:2007-05-01 00:00:00

  • Non-constrained monitoring of systolic blood pressure on a weighing scale.

    abstract::In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured usin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/011

    authors: Shin JH,Lee KM,Park KS

    更新日期:2009-07-01 00:00:00

  • Specific heat capacity of freshly excised prostate specimens.

    abstract::The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 3...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/11/N02

    authors: Patch SK,Rao N,Kelly H,Jacobsohn K,See WA

    更新日期:2011-11-01 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • Validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake.

    abstract::The purpose of this study was to determine the validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake (VO2max). Fifty-two healthy volunteers had their VO2max determined during a maximal treadmill run. They also performed a timed 5 km cycle ergometer ride. The resistance setting ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1088/0967-3334/17/4/009

    authors: Buono MJ,Borin TL,Sjoholm NT,Hodgdon JA

    更新日期:1996-11-01 00:00:00

  • A deep neural network for estimating the bladder boundary using electrical impedance tomography.

    abstract:OBJECTIVE:Accurate bladder size estimation is an important clinical parameter that assists physicians, enabling them to provide better treatment for patients who are suffering from urinary incontinence. Electrical impedance tomography (EIT) is a non-invasive medical imaging method that estimates organ boundaries assumi...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abaa56

    authors: Konki SK,Khambampati AK,Sharma SK,Kim KY

    更新日期:2020-12-18 00:00:00