Abstract:
:Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal wall has been developed to simulate aspects of the interaction between it and a suprapubic catheter. The simulator is based on a slab of ultrasoft elastomer with tensionable reinforcing polyamide filaments. The behaviour of the simulator has been compared with data published. A soft membrane (contact pressure) transducer (SMT) was used and novel instrumented 'tongs' for lateral indentation of the puncture track giving indentation stiffness. Slab materials were used with shear moduli of 0.1 and 0.021 MPa. Two filament-tensioning methods were used: by clamping to a winding mechanism and by weights. The combination of the softer slab material and tensioning by weights gave good conformity to physiological data; other combinations did not.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Coveney VA,Gröver Ddoi
10.1088/0967-3334/22/3/308subject
Has Abstractpub_date
2001-08-01 00:00:00pages
505-16issue
3eissn
0967-3334issn
1361-6579journal_volume
22pub_type
杂志文章abstract::Balance is the ability to maintain equilibrium while sitting or standing. There are a number of different methods which are used to assess balance: technical methods such as sway magnetometry, ataxia meter and force platforms, and clinical methods such as the functional reach test, Berg balance test and fall risk inde...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/4/309
更新日期:2000-11-01 00:00:00
abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/0967-3334/36/9/1889
更新日期:2015-09-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba07b
更新日期:2020-08-11 00:00:00
abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1435
更新日期:2012-09-01 00:00:00
abstract::Electrical impedance scanning (EIS) is a kind of potential bio-impedance measurement technology, especially aiding the diagnosis of breast cancer in women. By changing the frequency of the driving signal in turn while keeping the other conditions stable, multi-frequency measurement results on the object can be obtaine...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/7/S07
更新日期:2007-07-01 00:00:00
abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9e53
更新日期:2020-11-06 00:00:00
abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba80f
更新日期:2020-09-04 00:00:00
abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/24/2/310
更新日期:2003-05-01 00:00:00
abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab525c
更新日期:2019-12-02 00:00:00
abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S10
更新日期:2011-07-01 00:00:00
abstract::A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system befo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/2/001
更新日期:2011-02-01 00:00:00
abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/4/401
更新日期:2001-11-01 00:00:00
abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/34/6/713
更新日期:2013-06-01 00:00:00
abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/3/315
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa74d
更新日期:2018-02-28 00:00:00
abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/9/008
更新日期:2011-09-01 00:00:00
abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/1/308
更新日期:2003-02-01 00:00:00
abstract::We tested the hypothesis that transmission of arterial pressure to brain tissue oxygenation is low under conditions of arterial pressure instability. Two experimental models of hemodynamic instability were used in healthy human volunteers; (1) oscillatory lower body negative pressure (OLBNP) (N = 8; 5 male, 3 female),...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/4/785
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab02ab
更新日期:2019-02-26 00:00:00
abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1439
更新日期:2014-07-01 00:00:00
abstract::This paper investigates the main characteristics of the magneto-hemodynamic (MHD) response for application as a biomarker of vascular blood flow. The induced surface potential changes of a volunteer exposed to a 3 T static B0 field of a magnetic resonance imaging (MRI) magnet were measured over time at multiple locati...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/2/117
更新日期:2012-02-01 00:00:00
abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/4/309
更新日期:2002-11-01 00:00:00
abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/9/004
更新日期:2007-09-01 00:00:00
abstract::The aim of this study was to establish whether analysis of the left ventricular pressure waveform provides indicative information about cardiac load and contractility and to develop an algorithm for computer-based assessment of changes in these variables. In eight healthy standard breed anaesthetized open-chest pigs, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/12/003
更新日期:2006-12-01 00:00:00
abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/5/967
更新日期:2015-05-01 00:00:00
abstract::Heart rate variability (HRV) is often analysed using short-term studies. Our objective was to compare two of them in a group of diabetic patients (reduced HRV) and in a control group. From the same 10 min surface electrocardiogram (ECG) two recordings were obtained. In one of them the whole signal was acquired through...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/25/6/n01
更新日期:2004-12-01 00:00:00
abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aab7ac
更新日期:2018-04-26 00:00:00
abstract::A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/3/304
更新日期:2002-08-01 00:00:00
abstract::Nasal obstruction disturbs comfort during daytime, and sleep quality. Convenient objective assessment of nasal ventilation would be desirable. Therefore, we developed a technique for unobtrusive monitoring of bilateral nasal airflow. Nasal cannulae with separated left- and right-sided tubings were connected to two pre...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/1/007
更新日期:2005-02-01 00:00:00
abstract:OBJECTIVE:Idiopathic pulmonary fibrosis (IPF) is a progressive and fatal disease characterized by excessive deposition of collagen and associated stiffening of lung tissue. While it is known that inflammation and dysfunction of fibroblasts are involved in disease development, it remains poorly understood how cells and ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaca86
更新日期:2018-06-28 00:00:00