Capacitively-coupled ECG and respiration for the unobtrusive detection of sleep apnea.

Abstract:

OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and ccECG, combined with different unobtrusive respiratory measurements, including ECG derived respiration (EDR), respiratory effort measured using the thoracic belt (TB) and capacitively-coupled bioimpedance (ccBioz). Several ECG, respiratory and cardiorespiratory features were defined, of which the most relevant ones were identified using a random forest based backwards wrapper. Using this relevant feature set, a least-squares support vector machine classifier was trained to decide if a one minute segment is apneic or not, based on the annotated polysomnography (PSG) data of 218 patients suspected of having sleep apnea. The obtained classifier was then tested on the PSG and capacitively-coupled data of 28 different patients. MAIN RESULTS:On the PSG data, an AUC of 76.3 % was obtained when the ECG was combined with the EDR. Replacing the EDR with the TB led to an AUC of 80.0 %. Using the ccECG and ccBioz or the ccECG and TB resulted in similar performances as on the PSG data, while using the ccECG and ccECG-based EDR resulted in a drop in AUC to 67.4 %. SIGNIFICANCE:This is the first study which tests an apnea detection algorithm on capacitively-coupled ECG and bioimpedance signals and shows promising results on the capacitively-coupled data set. However, it was shown that the EDR could not be accurately estimated from the ccECG signals. Further research into the effect that respiration has on the ccECG is needed to propose alternative EDR estimates.

journal_name

Physiol Meas

authors

Deviaene M,Castro I,Borzée P,Patel A,Torfs T,Buyse B,Testelmans D,Van Huffel S,Varon C

doi

10.1088/1361-6579/abdf3d

subject

Has Abstract

pub_date

2021-01-22 00:00:00

eissn

0967-3334

issn

1361-6579

pub_type

杂志文章
  • Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

    abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/040

    authors: Ahadzi GM,Liston AD,Bayford RH,Holder DS

    更新日期:2004-02-01 00:00:00

  • A comparison of methods for estimating left ventricular volumes from radionuclide ventriculography.

    abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/1/004

    authors: Thorley PJ,Sheard KL,Rees MR

    更新日期:1993-02-01 00:00:00

  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT.

    abstract::We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially gene...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/8/S06

    authors: Hahn G,Dittmar J,Just A,Quintel M,Hellige G

    更新日期:2010-08-01 00:00:00

  • Permutation Lempel-Ziv complexity measure of electroencephalogram in GABAergic anaesthetics.

    abstract::Monitoring the brain state in anaesthesia is crucial for clinical doctors. In this study, we propose a novel nonlinear method, the permutation Lempel-Ziv complexity (PLZC) index, which describes the complexity in the electroencephalographic (EEG) signal to quantify the effect of GABAergic anaesthetics on brain activit...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/12/2483

    authors: Bai Y,Liang Z,Li X,Voss LJ,Sleigh JW

    更新日期:2015-12-01 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Time-related heart autonomic balance characteristics in healthy subjects.

    abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/3/309

    authors: Matveev M,Prokopova R,Nachev Ch

    更新日期:2003-08-01 00:00:00

  • The origin of skin-stretch-caused motion artifacts under electrodes.

    abstract::The outside of the skin of the forearm is typically 15 mV more negative than the inside. Stretching the skin causes a reduction in the magnitude of this skin potential V, which we observe as a motion artifact delta V. We seek to determine the origin of this motion artifact by successively stripping 12 layers of the sk...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/2/003

    authors: de Talhouet H,Webster JG

    更新日期:1996-05-01 00:00:00

  • Quantifying agitation in sedated ICU patients using heart rate and blood pressure.

    abstract::Agitation is a significant problem in the intensive care unit (ICU), affecting 71% of sedated adult patients during 58% of ICU patient-days (Fraser and Riker 2001 NY Health-Syst. Pharm. 20 17-24). Subjective scale-based assessment methods are currently used to assess the level of patient agitation, but are limited in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/4/020

    authors: Chase JG,Starfinger C,Lam Z,Agogue F,Shaw GM

    更新日期:2004-08-01 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallers.

    abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/009

    authors: Weiss A,Herman T,Plotnik M,Brozgol M,Giladi N,Hausdorff JM

    更新日期:2011-12-01 00:00:00

  • A practical approach to storage and retrieval of high-frequency physiological signals.

    abstract:OBJECTIVE:Storage of physiological waveform data for retrospective analysis presents significant challenges. Resultant data can be very large, and therefore becomes expensive to store and complicated to manage. Traditional database approaches are not appropriate for large scale storage of physiological waveforms. Our g...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7cb5

    authors: Goodwin AJ,Eytan D,Greer RW,Mazwi M,Thommandram A,Goodfellow SD,Assadi A,Jegatheeswaran A,Laussen PC

    更新日期:2020-04-20 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • The physiological impact of the nonlinearity of arterial elasticity in the ambulatory arterial stiffness index.

    abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/7/012

    authors: Craiem D,Graf S,Salvucci F,Chironi G,Megnien JL,Simon A,Armentano RL

    更新日期:2010-07-01 00:00:00

  • An intelligent ventilation and oxygenation management system in neonatal intensive care using fuzzy trend template fitting.

    abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/019

    authors: Belal SY,Taktak AF,Nevill A,Spencer A

    更新日期:2005-08-01 00:00:00

  • Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

    abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6d00

    authors: Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

    更新日期:2017-06-01 00:00:00

  • An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances.

    abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/008

    authors: Demidenko E

    更新日期:2011-09-01 00:00:00

  • Electroencephalogram classification in motor-imagery brain-computer interface applications based on double-constraint nonnegative matrix factorization.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba07b

    authors: Su J,Yang Z,Yan W,Sun W

    更新日期:2020-08-11 00:00:00

  • Sleep stage classification with ECG and respiratory effort.

    abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2027

    authors: Fonseca P,Long X,Radha M,Haakma R,Aarts RM,Rolink J

    更新日期:2015-10-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Thermography and colour duplex ultrasound assessments of arterio-venous fistula function in renal patients.

    abstract::Vascular and clinical assessments of arterio-venous fistula (AVF) function and access are important in patients undergoing or preparing to undergo renal dialysis. Objective assessment techniques include colour duplex ultrasound and more recently medical infrared thermography. Ideally, these should help assess problems...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/1/005

    authors: Allen J,Oates CP,Chishti AD,Ahmed IA,Talbot D,Murray A

    更新日期:2006-01-01 00:00:00

  • Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study.

    abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/008

    authors: King J,Mochalski P,Kupferthaler A,Unterkofler K,Koc H,Filipiak W,Teschl S,Hinterhuber H,Amann A

    更新日期:2010-09-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Classification of glucose concentration in diluted urine using the low-resolution Raman spectroscopy and kernel optimization methods.

    abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/5/011

    authors: Park C,Kim K,Choi J,Park K

    更新日期:2007-05-01 00:00:00

  • Circuit modeling of the electrical impedance: II. Normal subjects and system reproducibility.

    abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/2/223

    authors: Shiffman CA,Rutkove SB

    更新日期:2013-02-01 00:00:00

  • Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection.

    abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/8/006

    authors: Giansanti D,Maccioni G

    更新日期:2006-08-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

    abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/597

    authors: Li JH,Tsai CY,Huang HM

    更新日期:2014-04-01 00:00:00

  • Monitoring fetal maturation-objectives, techniques and indices of autonomic function.

    abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/aa5fca

    authors: Hoyer D,Żebrowski J,Cysarz D,Gonçalves H,Pytlik A,Amorim-Costa C,Bernardes J,Ayres-de-Campos D,Witte OW,Schleußner E,Stroux L,Redman C,Georgieva A,Payne S,Clifford G,Signorini MG,Magenes G,Andreotti F,Malberg H,Zaun

    更新日期:2017-05-01 00:00:00