Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT.

Abstract:

:We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially generated based on a 'living thorax model'. Physiological time courses and a typical distribution of errors caused by a typical Goe-MF II EIT system were used for the calculations which encompassed a range up to 50 times greater than the initial error level (4 microV(rms max)-400 microV(rms max)). Additionally, low-pass filtering and principal component analysis (PCA) were used to quantify the effect of preprocessing the raw data. The results demonstrate that all methods based on fitting the local to the global time course were superior to the common functional tomograms utilizing standard deviation or maximum and minimum detection. Ventilation distribution was best quantified by the so-called VT methods. Filling capacity--a lung tissue property--was least dependent on increasing error levels. The errors introduced by filtering are significant with respect to a quantitative analysis of ventilation distribution. A preprocessing of raw data by applying a PCA performed well on the data sets which had been constructed but were, nonetheless, realistic. This approach appears to be highly promising for application on real data which is known to be erroneous.

journal_name

Physiol Meas

authors

Hahn G,Dittmar J,Just A,Quintel M,Hellige G

doi

10.1088/0967-3334/31/8/S06

subject

Has Abstract

pub_date

2010-08-01 00:00:00

pages

S73-84

issue

8

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(10)39084-8

journal_volume

31

pub_type

杂志文章
  • Tracking boundary movement and exterior shape modelling in lung EIT imaging.

    abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1119

    authors: Biguri A,Grychtol B,Adler A,Soleimani M

    更新日期:2015-06-01 00:00:00

  • Ballistocardiography and seismocardiography detection of hemodynamic changes during simulated obstructive apnea.

    abstract:OBJECTIVE:To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS:Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab924b

    authors: Morra S,Hossein A,Gorlier D,Rabineau J,Chaumont M,Migeotte PF,Van De Borne P

    更新日期:2020-07-09 00:00:00

  • Estimation of sleep stages in a healthy adult population from optical plethysmography and accelerometer signals.

    abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9047

    authors: Beattie Z,Oyang Y,Statan A,Ghoreyshi A,Pantelopoulos A,Russell A,Heneghan C

    更新日期:2017-10-31 00:00:00

  • Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation.

    abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac9a9

    authors: Harju J,Tarniceriu A,Parak J,Vehkaoja A,Yli-Hankala A,Korhonen I

    更新日期:2018-06-27 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs.

    abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1273

    authors: Krasteva V,Jekova I,Leber R,Schmid R,Abächerli R

    更新日期:2016-08-01 00:00:00

  • Reference intervals for the evoked tympanic membrane displacement measurement: a non-invasive measure of intracranial pressure.

    abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa1d3

    authors: Campbell-Bell CM,Birch AA,Vignali D,Bulters D,Marchbanks RJ

    更新日期:2018-01-31 00:00:00

  • A measurement of pulmonary blood volume increase during systole in humans.

    abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/15/4/010

    authors: Nitzan M,Mahler Y,Schechter D,Yaffe S,Bocher M,Chisin R

    更新日期:1994-11-01 00:00:00

  • Development of a noncontact heart rate monitoring system for sedentary behavior based on an accelerometer attached to a chair.

    abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/3/N61

    authors: Lim E,Lee HK,Myoung HS,Lee KJ

    更新日期:2015-03-01 00:00:00

  • Treading on the unknown-the feasibility of a novel approach to investigating the motor control of walking.

    abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/1361-6579/aab659

    authors: Koren Y,Raanan Y,Parmet Y,Bar-Haim S

    更新日期:2018-04-26 00:00:00

  • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry.

    abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/3/008

    authors: Steel SA,Swann P,Langley G,Langton CM

    更新日期:1997-08-01 00:00:00

  • Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients.

    abstract::A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes cl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/11/1931

    authors: Schwenk M,Gogulla S,Englert S,Czempik A,Hauer K

    更新日期:2012-11-01 00:00:00

  • Restoration of the electrocardiogram during mechanical cardiopulmonary resuscitation.

    abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9e53

    authors: Isasi I,Irusta U,Aramendi E,Idris AH,Sörnmo L

    更新日期:2020-11-06 00:00:00

  • Detection of animal tissue thickness using simple vertical electric sounding (VES).

    abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/1/007

    authors: Gonzalez CA,offniga O,Padilla LE

    更新日期:1997-02-01 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Pilot acute study of feedback-controlled retrograde peristalsis invoked by neural gastric electrical stimulation.

    abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/3/006

    authors: Aelen P,Jurkov A,Aulanier A,Mintchev MP

    更新日期:2009-03-01 00:00:00

  • Development of a novel method for assessing balance: the quantitative posturography system.

    abstract::Balance is the ability to maintain equilibrium while sitting or standing. There are a number of different methods which are used to assess balance: technical methods such as sway magnetometry, ataxia meter and force platforms, and clinical methods such as the functional reach test, Berg balance test and fall risk inde...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/4/309

    authors: Browne J,O'Hare N

    更新日期:2000-11-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • Modelling of the immunoassay element of an optical immunosensor.

    abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/318

    authors: Keating SM,Flanagan MT

    更新日期:2001-08-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites.

    abstract::Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when rec...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/10/002

    authors: Kushki A,Fairley J,Merja S,King G,Chau T

    更新日期:2011-10-01 00:00:00

  • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/026

    authors: Nopp P,Zhao TX,Brown BH,Wang W

    更新日期:1996-11-01 00:00:00

  • The feasibility of transoesophageal bioimpedance measurements for the detection of heart graft rejection.

    abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S10

    authors: Giovinazzo G,Ribas N,Cinca J,Rosell-Ferrer J

    更新日期:2011-07-01 00:00:00

  • A finite element model of needle electrode spatial sensitivity.

    abstract::We used the finite element (FE) method to estimate the spatial sensitivity of a needle electrode for bioimpedance measurements. This current conducting needle with an insulated shaft was inserted in a saline solution and the current was measured at the neutral electrode. Model resistance and reactance were calculated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/006

    authors: Høyum P,Kalvøy H,Martinsen ØG,Grimnes S

    更新日期:2010-10-01 00:00:00

  • A support vector machine approach for AF classification from a short single-lead ECG recording.

    abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac7aa

    authors: Liu N,Sun M,Wang L,Zhou W,Dang H,Zhou X

    更新日期:2018-06-25 00:00:00

  • Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components.

    abstract::The paper presents a method for adaptive decomposition of an electrical bio-impedance (BI) signal into two components: cardiac and respiratory. The decomposition of a BI signal is not a trivial process because of the non-stationarity of the signal components and overlapping of their harmonic spectra. An application sp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S02

    authors: Krivoshei A,Kukk V,Min M

    更新日期:2008-06-01 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • New electrohysterogram-based estimators of intrauterine pressure signal, tonus and contraction peak for non-invasive labor monitoring.

    abstract:BACKGROUND:Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab37db

    authors: Benalcazar-Parra C,Garcia-Casado J,Ye-Lin Y,Alberola-Rubio J,Lopez Á,Perales-Marin A,Prats-Boluda G

    更新日期:2019-09-03 00:00:00

  • Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation.

    abstract:OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subs...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaeb2

    authors: Zhao Z,Wang W,Zhang Z,Xu M,Frerichs I,Wu J,Moeller K

    更新日期:2018-03-29 00:00:00

  • Hidden Markov model-based activity recognition for toddlers.

    abstract:OBJECTIVE:Physical activity has been shown to impact future health outcomes in adults, but little is known about the long-term impact of physical activity in toddlers. Accurately measuring the specific types and amounts of physical activity in toddlers will help us to understand, predict, and better affect their future...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab6ebb

    authors: Albert MV,Sugianto A,Nickele K,Zavos P,Sindu P,Ali M,Kwon S

    更新日期:2020-03-06 00:00:00