Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation.

Abstract:

OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subsequent OLV for thoracic surgical procedures were examined prospectively in lateral posture. Electrical impedance tomography (EIT), blood gases, respiratory mechanics were successfully measured in 21 patients at various combinations of V T (4 ml kg-1, 6 ml kg-1, 8 ml kg-1 body weight) and PEEP (0 cm H2O, 4 cm H2O, 8 cm H2O) during OLV. MAIN RESULTS:Low V T and low PEEP resulted in low global respiratory system compliance (C rs). Arterial partial pressure of O2 (PaO2) decreased with falling V T. Regional C rs measured with EIT showed high values at high V T and high PEEP in all but two patients. Regional C rs in mid and most dependent regions indicated tidal recruitment/derecruitment in eight patients at 8 ml kg-1 of V T and 4 cm H2O of PEEP; in four patients at 8 ml kg-1 and 0 cm H2O; in one patient at 6 ml kg-1 and 8 cm H2O. The changes in regional C rs induced by decreasing PEEP from 8 to 4 cm H2O were much smaller than those from 4 to 0 cm H2O. Ventilation distribution was most inhomogeneous with V T of 8 ml kg-1. All measures differed significantly among various V T and PEEP steps (p  <  0.05). SIGNIFICANCE:By using EIT in combination with PaO2, it is feasible to titrate V T and PEEP at the bedside during OLV.

journal_name

Physiol Meas

authors

Zhao Z,Wang W,Zhang Z,Xu M,Frerichs I,Wu J,Moeller K

doi

10.1088/1361-6579/aaaeb2

subject

Has Abstract

pub_date

2018-03-29 00:00:00

pages

034003

issue

3

eissn

0967-3334

issn

1361-6579

journal_volume

39

pub_type

杂志文章
  • Body fat prediction from skinfold anthropometry referenced to a new gold standard: in vivo neutron activation analysis and tritium dilution.

    abstract::Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat....

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/3/008

    authors: Beddoe AH,Samat SB

    更新日期:1998-08-01 00:00:00

  • Monitoring nasal conductance by bilateral nasal cannula pressure transducers.

    abstract::Nasal obstruction is common and may disturb well-being during daytime and sleep. Its objective assessment by standard methods requires patient cooperation and inconvenient instrumentation. Therefore, the purpose of this study was to develop a novel, unobtrusive technique for continuous monitoring of changes in nasal c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/014

    authors: Thurnheer R,Bloch KE

    更新日期:2004-04-01 00:00:00

  • Recording of ENGs from the nerves innervating the pancreas of a dog during the intravenous glucose tolerance test.

    abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/4/309

    authors: Rozman J,Zorko B,Bunc M,Mikac U,Tegou E

    更新日期:2002-11-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

    abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/009

    authors: Boone KG,Holder DS

    更新日期:1995-08-01 00:00:00

  • A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    abstract::This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameter...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/2/238

    authors: Martinek R,Kelnar M,Koudelka P,Vanus J,Bilik P,Janku P,Nazeran H,Zidek J

    更新日期:2016-02-01 00:00:00

  • Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

    abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6d00

    authors: Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

    更新日期:2017-06-01 00:00:00

  • Potential neuroprotective effects of acupuncture stimulation on diabetes mellitus in a global ischemic rat model.

    abstract::Acupuncture (ACU) is known to be effective in ischemia treatment, and glutamate (GLU) excitotoxicity is an important factor in neuronal cell death. We observed the effect of ACU on cerebral blood flow (%CBF) and DeltaGLU (the changes in GLU release) in the ischemic stroke rat model of diabetic mellitus (DM). A global ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/5/003

    authors: Choi S,Lee GJ,Chae SJ,Kang SW,Yin CS,Lee SH,Choi SK,Park HK

    更新日期:2010-05-01 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • The independent components of auditory P300 and CNV evoked potentials derived from single-trial recordings.

    abstract::The back-projected independent components (BICs) of single-trial, auditory P300 and contingent negative variation (CNV) evoked potentials (EPs) were derived using independent component analysis (ICA) and cluster analysis. The method was tested in simulation including a study of the electric dipole equivalents of the s...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/8/001

    authors: Jervis B,Belal S,Camilleri K,Cassar T,Bigan C,Linden DE,Michalopoulos K,Zervakis M,Besleaga M,Fabri S,Muscat J

    更新日期:2007-08-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • Validation of a finite-element solution for electrical impedance tomography in an anisotropic medium.

    abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S10

    authors: Abascal JF,Arridge SR,Lionheart WR,Bayford RH,Holder DS

    更新日期:2007-07-01 00:00:00

  • Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm.

    abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/27/3/002

    authors: Tarvainen MP,Georgiadis SD,Ranta-Aho PO,Karjalainen PA

    更新日期:2006-03-01 00:00:00

  • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry.

    abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/3/008

    authors: Steel SA,Swann P,Langley G,Langton CM

    更新日期:1997-08-01 00:00:00

  • Triple-frequency method for measuring blood impedance.

    abstract::A method was developed for simultaneously measuring plasma resistance, cell interior resistance and cell membrane capacitance of blood. A three-element circuit model for simulating the impedance of blood was evaluated by comparing measured and calculated impedance frequency curves and was found feasible. The values of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/2/006

    authors: Zhao TX,Jacobson B,Ribbe T

    更新日期:1993-05-01 00:00:00

  • Repeatability of body sway measurements; day-to-day variation measured by sway magnetometry.

    abstract::The postural stability of 30 normal subjects in the age range 15 to 64 years was measured on five separate occasions, using the sway magnetometry technique, to determine the day-to-day repeatability of this measurement technique. On each occasion the pathlength and area enclosed by movement of the hips in a horizontal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/2/003

    authors: Elliott C,Murray A

    更新日期:1998-05-01 00:00:00

  • Non-contact video-based vital sign monitoring using ambient light and auto-regressive models.

    abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/5/807

    authors: Tarassenko L,Villarroel M,Guazzi A,Jorge J,Clifton DA,Pugh C

    更新日期:2014-05-01 00:00:00

  • A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.

    abstract:OBJECTIVE:Currently, continuous blood pressure (BP) measurements are mostly based on multi-sensor combinations and datasets with limited BP ranges. Besides, most BP-related features derive from the photoplethysmogram (PPG) signal. The mechanism of PPG signal formation is not considered. We aimed to design a noninvasive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc8dd

    authors: Hu Q,Deng X,Wang A,Yang C

    更新日期:2021-01-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components.

    abstract::The paper presents a method for adaptive decomposition of an electrical bio-impedance (BI) signal into two components: cardiac and respiratory. The decomposition of a BI signal is not a trivial process because of the non-stationarity of the signal components and overlapping of their harmonic spectra. An application sp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S02

    authors: Krivoshei A,Kukk V,Min M

    更新日期:2008-06-01 00:00:00

  • Predicting clinical ischaemia during awake carotid endarterectomy: use of the SJVO2 probe as a guide to selective shunting.

    abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/2/310

    authors: Crossman J,Banister K,Bythell V,Bullock R,Chambers I,Mendelow AD

    更新日期:2003-05-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • Effects of awareness and nociception on heart rate variability during general anaesthesia.

    abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/207

    authors: Huhle R,Burghardt M,Zaunseder S,Wessel N,Koch T,Malberg H,Heller AR

    更新日期:2012-02-01 00:00:00

  • Correlation between maximal radial muscle displacement and stiffness in gastrocnemius muscle.

    abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abcdf4

    authors: Labata-Lezaun N,López-de-Celis C,Llurda-Almuzara L,González-Rueda V,Cadellans-Arróniz A,Pérez-Bellmunt A

    更新日期:2020-12-31 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • A method of reducing the error caused by boundary shape and electrode positions in electrical impedance tomography.

    abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/022

    authors: Li J

    更新日期:1994-05-01 00:00:00

  • An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallers.

    abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/009

    authors: Weiss A,Herman T,Plotnik M,Brozgol M,Giladi N,Hausdorff JM

    更新日期:2011-12-01 00:00:00

  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • Time-frequency analysis of heart rate variability using short-time fourier analysis.

    abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/2/303

    authors: Elsenbruch S,Wang Z,Orr WC,Chen JD

    更新日期:2000-05-01 00:00:00