Body fat prediction from skinfold anthropometry referenced to a new gold standard: in vivo neutron activation analysis and tritium dilution.

Abstract:

:Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat. Nevertheless this preliminary study shows that the residual error can be reduced by referencing to a gold standard other than body density. Using a difference technique involving in vivo neutron activation analysis and tritiated water dilution, this paper shows that at least in 20-29 year old normal subjects the residual error (expressed as a percentage of mean total body fat in the respective groups) can be reduced from 22% to 16% (p < 0.001) in males and from 17% to 9% in females (p < 0.0001). It is suggested that a large scale study could be initiated with this new gold standard to obtain accurate predictor relationships throughout the whole age range for both sexes.

journal_name

Physiol Meas

authors

Beddoe AH,Samat SB

doi

10.1088/0967-3334/19/3/008

subject

Has Abstract

pub_date

1998-08-01 00:00:00

pages

393-403

issue

3

eissn

0967-3334

issn

1361-6579

journal_volume

19

pub_type

杂志文章
  • Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery.

    abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/002

    authors: Alam I,Lewis MJ,Morgan J,Baxter J

    更新日期:2009-07-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

    abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/001

    authors: Brown BH,Barber DC,Wang W,Lu L,Leathard AD,Smallwood RH,Hampshire AR,Mackay R,Hatzigalanis K

    更新日期:1994-05-01 00:00:00

  • In vivo neutron activation analysis of bone manganese in workers.

    abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa749

    authors: Liu Y,Rolle-McFarland D,Mostafaei F,Zhou Y,Li Y,Zheng W,Wells E,Nie LH

    更新日期:2018-03-23 00:00:00

  • A support vector machine approach for AF classification from a short single-lead ECG recording.

    abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac7aa

    authors: Liu N,Sun M,Wang L,Zhou W,Dang H,Zhou X

    更新日期:2018-06-25 00:00:00

  • Multi-frequency parameter mapping of electrical impedance scanning using two kinds of circuit model.

    abstract::Electrical impedance scanning (EIS) is a kind of potential bio-impedance measurement technology, especially aiding the diagnosis of breast cancer in women. By changing the frequency of the driving signal in turn while keeping the other conditions stable, multi-frequency measurement results on the object can be obtaine...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S07

    authors: Liu R,Dong X,Fu F,You F,Shi X,Ji Z,Wang K

    更新日期:2007-07-01 00:00:00

  • Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG.

    abstract:OBJECTIVE:To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND:Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physic...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840a

    authors: Kinnunen H,Rantanen A,Kenttä T,Koskimäki H

    更新日期:2020-05-07 00:00:00

  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • Snore site discrimination using statistical moments of free field snoring sounds recorded during sleep nasendoscopy.

    abstract::The non-invasive measurement of free field snoring sounds to estimate the site of snoring is an important development in the diagnosis, treatment and management of sleep-related breathing disorders. We investigated characteristics of the probability density function by testing the sensitivity of the statistical moment...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/10/008

    authors: Beeton RJ,Wells I,Ebden P,Whittet HB,Clarke J

    更新日期:2007-10-01 00:00:00

  • Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

    abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/009

    authors: Boone KG,Holder DS

    更新日期:1995-08-01 00:00:00

  • Topographic distribution of idiopathic pulmonary fibrosis: a hybrid physics- and agent-based model.

    abstract:OBJECTIVE:Idiopathic pulmonary fibrosis (IPF) is a progressive and fatal disease characterized by excessive deposition of collagen and associated stiffening of lung tissue. While it is known that inflammation and dysfunction of fibroblasts are involved in disease development, it remains poorly understood how cells and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaca86

    authors: Wellman TJ,Mondoñedo JR,Davis GS,Bates JHT,Suki B

    更新日期:2018-06-28 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise.

    abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/5/008

    authors: Wang L,Poon CC,Zhang YT

    更新日期:2010-05-01 00:00:00

  • An abdominal wall simulator for testing suprapubic urinary catheters.

    abstract::Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/308

    authors: Coveney VA,Gröver D

    更新日期:2001-08-01 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • Predicting clinical ischaemia during awake carotid endarterectomy: use of the SJVO2 probe as a guide to selective shunting.

    abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/2/310

    authors: Crossman J,Banister K,Bythell V,Bullock R,Chambers I,Mendelow AD

    更新日期:2003-05-01 00:00:00

  • Non-invasive measurements of respiratory system mechanical properties by the forced oscillation technique in spontaneously breathing, mixed-breed, normal term lambs from birth to five months of age.

    abstract:OBJECTIVE:To provide a non-invasive approach to monitoring lung function in spontaneously breathing lambs, from birth to five months of life, by the forced oscillation technique (FOT). This report describes the experimental set-up, data processing, and identification of normal predicted values of resistance (Rrs) and r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab3493

    authors: Veneroni C,Dahl MJ,Lavizzari A,Dawson E,Rebentisch A,Studstill S,Bowen S,Albertine KH,Dellaca RL

    更新日期:2019-11-04 00:00:00

  • A method for modelling and optimizing an electrical impedance tomography system.

    abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/5/S05

    authors: Hartinger AE,Gagnon H,Guardo R

    更新日期:2006-05-01 00:00:00

  • The origin of skin-stretch-caused motion artifacts under electrodes.

    abstract::The outside of the skin of the forearm is typically 15 mV more negative than the inside. Stretching the skin causes a reduction in the magnitude of this skin potential V, which we observe as a motion artifact delta V. We seek to determine the origin of this motion artifact by successively stripping 12 layers of the sk...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/2/003

    authors: de Talhouet H,Webster JG

    更新日期:1996-05-01 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • Assessment of the dynamic interactions between heart rate and arterial pressure by the cross time-frequency analysis.

    abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/3/315

    authors: Orini M,Laguna P,Mainardi LT,Bailón R

    更新日期:2012-03-01 00:00:00

  • Differences in the microcirculatory effects of local skin surface contact pressure stimulation between acupoints and nonacupoints: possible relevance to acupressure.

    abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/6/007

    authors: Hsiu H,Hsu WC,Chen BH,Hsu CL

    更新日期:2010-06-01 00:00:00

  • Automatic sleep-stage scoring based on photoplethysmographic signals.

    abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921d

    authors: Wu X,Yang J,Pan Y,Zhang X,Luo Y

    更新日期:2020-06-30 00:00:00

  • The influence of cardiac preload and positive end-expiratory pressure on the pre-ejection period.

    abstract::The pre-ejection period (PEP) has recently been described as a potential parameter for monitoring cardiac preload. This study further investigated the influence of changes in intravascular volume status and the application of positive end-expiratory pressure (PEEP) on the pre-ejection period. In ten pigs, ECG, arteria...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/012

    authors: Kubitz JC,Kemming GI,Schultheib G,Starke J,Podtschaske A,Goetz AE,Reuter DA

    更新日期:2005-12-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • Modelling the cerebral haemodynamic response in the physiological range of PaCO2.

    abstract:OBJECTIVE:Arterial CO2 (PaCO2) has a strong effect on cerebral blood flow (CBF), but its influence on CBF regulatory mechanisms and circulatory systemic variables has not been fully described over the entire physiological range of PaCO2. APPROACH:CBF velocity (CBFV, transcranial Doppler), blood pressure (BP, Finometer...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac76b

    authors: Minhas JS,Panerai RB,Robinson TG

    更新日期:2018-06-19 00:00:00

  • The influence of dilution on the offline measurement of exhaled nitric oxide.

    abstract:OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The internati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa455

    authors: MacBean V,Pooranampillai D,Howard C,Lunt A,Greenough A

    更新日期:2018-02-26 00:00:00

  • Comparison of four different FIM configurations--a simulation study.

    abstract::Focused impedance measurements (FIM) are used in several fields, and address the problem of measuring the volume impedance of an object within a volume conductor. Several electrode configurations are possible, and these have different properties. Sensitivity fields of four configurations have been investigated. We pre...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1067

    authors: Pettersen FJ,Ferdous H,Kalvøy H,Martinsen ØG,Høgetveit JO

    更新日期:2014-06-01 00:00:00

  • Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1035

    authors: Grychtol B,Adler A

    更新日期:2014-06-01 00:00:00

  • Video and audio processing in paediatrics: a review.

    abstract:OBJECTIVE:Video and sound acquisition and processing technologies have seen great improvements in recent decades, with many applications in the biomedical area. The aim of this paper is to review the overall state of the art of advances within these topics in paediatrics and to evaluate their potential application for ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab0096

    authors: Cabon S,Porée F,Simon A,Rosec O,Pladys P,Carrault G

    更新日期:2019-02-26 00:00:00