Abstract:
OBJECTIVE:To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS:Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signals were simultaneously taken. The kinetic energy of a set of cardiac cycles before and during the apneic episode was automatically computed from the rotational and linear channels of the SCG and BCG waveforms and its temporal integral (i K) was derived (unit of measure: microjoules per second (µJ·s)). The estimated transmural pressure (eP TM ) was assessed as the difference between systemic blood pressure and maximal inspiratory pressure (MIP). The Wilcoxon sign-rank test was used to evaluate differences in energy measurements between normal respiration and the loaded inspiration maneuver. Cardiac kinetic energies and the MIP produced during the MM were compared by linear regression analysis following log transformation in order to assess the correlation between variables. MAIN RESULTS:The [Formula: see text] during normal breathing increased from 1.1(0.8; 1.4) to 1.9(1.4; 4.3) µJ·s during MM (p < 0.001). Meanwhile, [Formula: see text] increased from 54 (31; 92) to 84 (44; 153) µJ·s, (p < 0.001). The [Formula: see text] and [Formula: see text] of a set of cardiac cycles during the MM were negatively associated with the MIP (r: -0.59, p < 0.001 and r: -0.53, p = 0.001 for [Formula: see text] and [Formula: see text], respectively). When eP TM was considered, this association became positive (r: +0.58, p < 0.001 and r:+0.60, p < 0.001, for [Formula: see text] and [Formula: see text], respectively). When the i K LIN was considered as the comparative factor, correlations with the MIP and eP TM were weak and insignificant. Men had higher values of i K than women. SIGNIFICANCE:Simulated obstructive apnea elicits large rotational i K swings, which are related to the intensity of the inspiratory effort and, as such, to the intensity of the left ventricular afterload. Computation of cardiac kinetic energy through BCG and SCG may shed further light on the impact of obstructive respiratory events on the cardiovascular system.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Morra S,Hossein A,Gorlier D,Rabineau J,Chaumont M,Migeotte PF,Van De Borne Pdoi
10.1088/1361-6579/ab924bsubject
Has Abstractpub_date
2020-07-09 00:00:00pages
065007issue
6eissn
0967-3334issn
1361-6579journal_volume
41pub_type
杂志文章abstract::This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameter...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/2/238
更新日期:2016-02-01 00:00:00
abstract::The non-invasive measurement of free field snoring sounds to estimate the site of snoring is an important development in the diagnosis, treatment and management of sleep-related breathing disorders. We investigated characteristics of the probability density function by testing the sensitivity of the statistical moment...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/10/008
更新日期:2007-10-01 00:00:00
abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/7/1163
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaaaa0
更新日期:2018-02-28 00:00:00
abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/9/N01
更新日期:2008-09-01 00:00:00
abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/4a/004
更新日期:1993-11-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aace95
更新日期:2018-07-16 00:00:00
abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2/002
更新日期:1994-05-01 00:00:00
abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac7aa
更新日期:2018-06-25 00:00:00
abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/5/005
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cogn...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab979e
更新日期:2020-07-07 00:00:00
abstract:OBJECTIVE:This paper aims to present how physiological signals can be processed based on wavelet decomposition to calculate multiple physiological parameters in real-time on an embedded platform. APPROACH:An ECG and PPG are decomposed to the appropriate scale based on a quadratic spline wavelet base in order to obtain...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab6f52
更新日期:2020-03-06 00:00:00
abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/11/1483
更新日期:2013-11-01 00:00:00
abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/2/004
更新日期:2006-02-01 00:00:00
abstract::The left atrium (LA) plays an important role in the maintenance of hemodynamic and electrical stability of the heart. One of the conditions altering the atrial mechanical function is atrial fibrillation (AF), leading to an increased thromboembolic risk due to impaired mechanical function. Preserving the regions of the...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/5/763
更新日期:2014-05-01 00:00:00
abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1435
更新日期:2012-09-01 00:00:00
abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/001
更新日期:1994-05-01 00:00:00
abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/3/010
更新日期:2005-06-01 00:00:00
abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/026
更新日期:1996-11-01 00:00:00
abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/9/1624
更新日期:2016-09-01 00:00:00
abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa749
更新日期:2018-03-23 00:00:00
abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/008
更新日期:2005-10-01 00:00:00
abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/4/001
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abdf3d
更新日期:2021-01-22 00:00:00
abstract::Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/6/S08
更新日期:2008-06-01 00:00:00
abstract::Electrocardiograms (ECGs) recorded from patients in intensive care were investigated to quantify any relationship between ECG signal quality and false monitoring alarms. False alarms are a considerable problem for nursing and medical staff as they distract from clinical care, and are also a problem for patients as the...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/8/1383
更新日期:2016-08-01 00:00:00
abstract:OBJECTIVE:Advanced neuroimaging has proved to be pivotal in the management of acute ischemic stroke. The use of CT perfusion (CTP) core and penumbra parameters to predict the outcome in wake-up stroke (WUS) patients in everyday clinical scenarios has not yet been investigated. The aim of our study was to investigate th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9c70
更新日期:2020-08-11 00:00:00
abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/8/1335
更新日期:2012-08-01 00:00:00
abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/10/2159
更新日期:2015-10-01 00:00:00