Abstract:
OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algorithm consisted of three steps: (1) signal pre-processing based on the wavelet method; (2) feature extraction, the extracted features including one power feature, two spectrum features, two entropy features, 17 RR interval-related features, and 11 P wave features; and (3) classification using the SVM classifier. MAIN RESULTS:The algorithm was trained by 8528 single-lead ECG recordings lasting from 9 s to just over 60 s and then tested on a hidden test set consisting of 3658 recordings of similar lengths, which were all provided by the PhysioNet/Computing in Cardiology Challenge 2017. The scoring for this challenge used an F 1 measure, and the final F 1 score was defined as the average of F 1n (the F 1 score of normal rhythm), F 1a (the F 1 score of AF rhythm), and F 1o (the F 1 score of other rhythm). The results confirmed the high accuracy of our proposed method, which obtained 90.27%, 86.37%, and 75.08% for F 1n , F 1a , and F 1n and the final F 1 score of 84% on the training set. In the final test to assess the performance of all of the hidden data, the obtained F 1n , F 1a , F 1o and the average F 1 were 90.82%, 78.56%, 71.77% and 80%, respectively. SIGNIFICANCE:The proposed algorithm targets a large number of raw, short single ECG data rather than a small number of carefully selected, often clean ECG records, which have been studied in most of the previous literature. It breaks through the limitation in applicability and provides reliable AF detection from a short single-lead ECG.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Liu N,Sun M,Wang L,Zhou W,Dang H,Zhou Xdoi
10.1088/1361-6579/aac7aasubject
Has Abstractpub_date
2018-06-25 00:00:00pages
064004issue
6eissn
0967-3334issn
1361-6579journal_volume
39pub_type
杂志文章abstract:OBJECTIVE:Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals' short biologic half-lives, shipping and storage requirement...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aad947
更新日期:2018-08-31 00:00:00
abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa1d3
更新日期:2018-01-31 00:00:00
abstract::Myoelectrical pattern classification is a crucial part in multi-functional prosthesis control. This paper investigates a discriminant Fourier-derived cepstrum (DFC) and feature-level post-processing (FLPP) to discriminate hand and wrist motions using the surface electromyographic signal. The Fourier-derived cepstrum t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/12/008
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subs...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaaeb2
更新日期:2018-03-29 00:00:00
abstract:OBJECTIVE:Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cogn...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab979e
更新日期:2020-07-07 00:00:00
abstract::We aim to investigate whether phase shift between respiratory oscillations in cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) is associated with changes in cerebral autoregulation (CA) or reflects the mechano-elastic properties of the cerebrovascular bed. The relationships between respiratory pha...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/38/2/310
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00
abstract::EPR oximetry is a promising, relatively non-invasive method for monitoring the partial pressure of oxygen in tissue (PtO2) that has proved useful in following changes under various physiologic and pathophysiologic conditions. Optimal utilization of the method will be facilitated by systematic comparisons with other av...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/6/007
更新日期:2004-12-01 00:00:00
abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/303
更新日期:2001-02-01 00:00:00
abstract::Nasal obstruction disturbs comfort during daytime, and sleep quality. Convenient objective assessment of nasal ventilation would be desirable. Therefore, we developed a technique for unobtrusive monitoring of bilateral nasal airflow. Nasal cannulae with separated left- and right-sided tubings were connected to two pre...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/1/007
更新日期:2005-02-01 00:00:00
abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/1/005
更新日期:2008-01-01 00:00:00
abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/3/010
更新日期:2005-06-01 00:00:00
abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/018
更新日期:2005-10-01 00:00:00
abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/5/005
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba07b
更新日期:2020-08-11 00:00:00
abstract::This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameter...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/2/238
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The internati...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa455
更新日期:2018-02-26 00:00:00
abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/12/009
更新日期:2011-12-01 00:00:00
abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2/002
更新日期:1994-05-01 00:00:00
abstract:OBJECTIVE:The healing of wounds is critical in protecting the human body against environmental factors. The mechanisms involving protein expression during this complex physiological process have not been fully elucidated. APPROACH:Here, we use reverse-phase protein microarrays (RPPA) involving 94 phosphoproteins to st...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaee19
更新日期:2018-12-07 00:00:00
abstract::Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/4/517
更新日期:2014-04-01 00:00:00
abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/7/1163
更新日期:2016-07-01 00:00:00
abstract::Vascular and clinical assessments of arterio-venous fistula (AVF) function and access are important in patients undergoing or preparing to undergo renal dialysis. Objective assessment techniques include colour duplex ultrasound and more recently medical infrared thermography. Ideally, these should help assess problems...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/1/005
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abcdf4
更新日期:2020-12-31 00:00:00
abstract::Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/4/006
更新日期:2008-04-01 00:00:00
abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/301
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:Doppler ultrasound (US) is the most commonly applied method to measure the fetal heart rate (fHR). When the fetal heart is not properly located within the ultrasonic beam, fHR measurements often fail. As a consequence, clinical staff need to reposition the US transducer on the maternal abdomen, which can be a...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa8a1a
更新日期:2017-09-21 00:00:00
abstract::Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/001
更新日期:2007-05-01 00:00:00
abstract::Previous studies have proved that the baroreceptor reflex (baroreflex) control of heart rate can be used for stratification of post-infarction population and, in general, cardiovascular disease populations. Many methods have been proposed to estimate the so-called baroreflex sensitivity (BRS) expressed as ms mmhg-1. M...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/38/1/63