Abstract:
:This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG + STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Martinek R,Kelnar M,Koudelka P,Vanus J,Bilik P,Janku P,Nazeran H,Zidek Jdoi
10.1088/0967-3334/37/2/238subject
Has Abstractpub_date
2016-02-01 00:00:00pages
238-56issue
2eissn
0967-3334issn
1361-6579journal_volume
37pub_type
杂志文章abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/30/9/R01
更新日期:2009-09-01 00:00:00
abstract::Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/6/1161
更新日期:2015-06-01 00:00:00
abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba80f
更新日期:2020-09-04 00:00:00
abstract::This paper introduces a new clinical distortion index able to measure the decrease in diagnostic content in compressed echocardiograms. It is calculated using cardiologists' answers to a clinical testbed composed of two types of tests: one blind and the other semi-blind. This index may be used to compare clinical perf...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/5/001
更新日期:2009-05-01 00:00:00
abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S10
更新日期:2011-07-01 00:00:00
abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/2/367
更新日期:2003-05-01 00:00:00
abstract::Vascular and clinical assessments of arterio-venous fistula (AVF) function and access are important in patients undergoing or preparing to undergo renal dialysis. Objective assessment techniques include colour duplex ultrasound and more recently medical infrared thermography. Ideally, these should help assess problems...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/1/005
更新日期:2006-01-01 00:00:00
abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/7/S10
更新日期:2007-07-01 00:00:00
abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/3/006
更新日期:2008-03-01 00:00:00
abstract::Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space ar...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa7256
更新日期:2017-07-24 00:00:00
abstract::This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvemen...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/26/3/R02
更新日期:2005-06-01 00:00:00
abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/34/6/713
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVE:Video and sound acquisition and processing technologies have seen great improvements in recent decades, with many applications in the biomedical area. The aim of this paper is to review the overall state of the art of advances within these topics in paediatrics and to evaluate their potential application for ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab0096
更新日期:2019-02-26 00:00:00
abstract::We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially gene...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/8/S06
更新日期:2010-08-01 00:00:00
abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/7/002
更新日期:2009-07-01 00:00:00
abstract:OBJECTIVE:Storage of physiological waveform data for retrospective analysis presents significant challenges. Resultant data can be very large, and therefore becomes expensive to store and complicated to manage. Traditional database approaches are not appropriate for large scale storage of physiological waveforms. Our g...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab7cb5
更新日期:2020-04-20 00:00:00
abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/11/1513
更新日期:2013-11-01 00:00:00
abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/8/1335
更新日期:2012-08-01 00:00:00
abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab0daa
更新日期:2019-04-03 00:00:00
abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/007
更新日期:1994-05-01 00:00:00
abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9047
更新日期:2017-10-31 00:00:00
abstract::External defibrillation requires the application of high voltage electrical impulses via large external electrodes, placed on selected locations on the thorax surface. The position of the electrodes is one of the major determinants of the transthoracic impedance (TTI) which influences the intracardiac current flow dur...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/10/007
更新日期:2006-10-01 00:00:00
abstract::Objective assessment of stroke-patients' ability to control arm movements is vital for evidence-based therapy and progress monitoring. This study compares three different indices to quantify the quality of wrist movement during a task involving tracking a target on a screen. Each method is assessed in terms of agreeme...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/8/011
更新日期:2007-08-01 00:00:00
abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/1/83
更新日期:2016-01-01 00:00:00
abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1435
更新日期:2012-09-01 00:00:00
abstract::Hand bone equivalent phantoms (250 ml) carrying selenium in various amounts were irradiated and counted for in vivo neutron activation analysis (IVNAA) by employing a 4π NaI(TI) based detection system. During the analysis of counting data, a feature at a higher energy than the gamma ray peak from (77m)Se (0.162 MeV) w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/12/N127
更新日期:2015-12-01 00:00:00
abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/008
更新日期:2005-10-01 00:00:00
abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1669
更新日期:2016-10-01 00:00:00
abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/4/003
更新日期:1995-11-01 00:00:00
abstract::Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a mu...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/4/767
更新日期:2015-04-01 00:00:00