Abstract:
OBJECTIVE:Doppler ultrasound (US) is the most commonly applied method to measure the fetal heart rate (fHR). When the fetal heart is not properly located within the ultrasonic beam, fHR measurements often fail. As a consequence, clinical staff need to reposition the US transducer on the maternal abdomen, which can be a time consuming and tedious task. APPROACH:In this article, a method is presented to aid clinicians with the positioning of the US transducer to produce robust fHR measurements. A maximum likelihood estimation (MLE) algorithm is developed, which provides information on fetal heart location using the power of the Doppler signals received in the individual elements of a standard US transducer for fHR recordings. The performance of the algorithm is evaluated with simulations and in vitro experiments performed on a beating-heart setup. MAIN RESULTS:Both the experiments and the simulations show that the heart location can be accurately determined with an error of less than 7 mm within the measurement volume of the employed US transducer. SIGNIFICANCE:The results show that the developed algorithm can be used to provide accurate feedback on fetal heart location for improved positioning of the US transducer, which may lead to improved measurements of the fHR.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Hamelmann P,Vullings R,Schmitt L,Kolen AF,Mischi M,van Laar JOEH,Bergmans JWMdoi
10.1088/1361-6579/aa8a1asubject
Has Abstractpub_date
2017-09-21 00:00:00pages
1821-1836issue
10eissn
0967-3334issn
1361-6579journal_volume
38pub_type
杂志文章abstract:OBJECTIVE:Arterial CO2 (PaCO2) has a strong effect on cerebral blood flow (CBF), but its influence on CBF regulatory mechanisms and circulatory systemic variables has not been fully described over the entire physiological range of PaCO2. APPROACH:CBF velocity (CBFV, transcranial Doppler), blood pressure (BP, Finometer...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac76b
更新日期:2018-06-19 00:00:00
abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/1/31
更新日期:2014-01-01 00:00:00
abstract::A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes cl...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/11/1931
更新日期:2012-11-01 00:00:00
abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/2/003
更新日期:2005-04-01 00:00:00
abstract::Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendab...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/6/S25
更新日期:2008-06-01 00:00:00
abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/19/1/008
更新日期:1998-02-01 00:00:00
abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/4/001
更新日期:2007-04-01 00:00:00
abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/16/3a/009
更新日期:1995-08-01 00:00:00
abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/6/1119
更新日期:2015-06-01 00:00:00
abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/7/S10
更新日期:2007-07-01 00:00:00
abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/006
更新日期:1996-11-01 00:00:00
abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/4/010
更新日期:1997-11-01 00:00:00
abstract::Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dime...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/3/009
更新日期:1993-08-01 00:00:00
abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/14/4a/014
更新日期:1993-11-01 00:00:00
abstract::Accelerometer wear location may influence physical activity estimates. This study investigates this relationship through the examination of activity patterns throughout the day. Participants from the aging research evaluating accelerometry (AREA) study (n men = 37, n women = 47, mean age (SD) = 78.9 (5.5) years)...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1852
更新日期:2016-10-01 00:00:00
abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/1/005
更新日期:2008-01-01 00:00:00
abstract::The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1349
更新日期:2014-07-01 00:00:00
abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/2/004
更新日期:2006-02-01 00:00:00
abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/24/2/310
更新日期:2003-05-01 00:00:00
abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/7/1163
更新日期:2016-07-01 00:00:00
abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/11/1483
更新日期:2013-11-01 00:00:00
abstract::Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almos...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/33/2/243
更新日期:2012-02-01 00:00:00
abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/011
更新日期:2004-02-01 00:00:00
abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/aa5fca
更新日期:2017-05-01 00:00:00
abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/31/6/007
更新日期:2010-06-01 00:00:00
abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/2/009
更新日期:2005-04-01 00:00:00
abstract::A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/3/304
更新日期:2002-08-01 00:00:00
abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac553
更新日期:2018-06-19 00:00:00
abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/10/2027
更新日期:2015-10-01 00:00:00
abstract::The use of artificial neural networks (ANNs) to interpret sleep monitoring signals is described. Recordings from ten infants with apparent life threatening episodes were assigned into training feedforward R-PROP networks. In order to separate good signal from artefact, 60 second time frames of SaO2 and TcPO2 signals w...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/21/3/401
更新日期:2000-08-01 00:00:00