Feasibility of long-term cerebral and peripheral regional tissue oxygen saturation measurements.

Abstract:

:The aim of this study was to analyse the feasibility of long-term measurements of cerebral (crSO2) and peripheral (prSO2) regional tissue oxygen saturation on the first day of life by determining the amount of artefacts and their influence on rSO2. Near infrared spectroscopy (NIRS) measurements were performed fronto-parietal left (crSO2) and on the right forearm (prSO2). Arterial oxygen saturation (SpO2) was measured by pulse oximetry on the right wrist. Three criteria (C) were defined to identify artefacts (C1: missing values, C2: rSO2 jumping >15%, C3: rSO2 ≥ SpO2). The number of artefacts as a percentage of measurement time and mean rSO2 was calculated after the introduction of each criterion. Measurements were performed in 40 neonates. The number of artefacts in crSO2 measurements was similar after introduction of C1 (7.37 ± 4.64%) and after introduction of all criteria (8.89 ± 4.59%). The number of artefacts in prSO2 measurements after introduction of C1 was 10.83 ± 4.21%, and after introduction of all criteria significantly higher with 17.78 ± 4.27%. After introduction of C1, further criteria did not significantly change rSO2: crSO2 (78.6 ± 1.3% versus 78.5 ± 1.2%) and prSO2 (83.7 ± 0.9% versus 83.5 ± 0.9%). In conclusion, long-term NIRS measurements of crSO2 and prSO2 are feasible, since most artefacts are due to missing values and therefore easy to recognize.

journal_name

Physiol Meas

authors

Schmitz J,Pichler G,Schwaberger B,Urlesberger B,Baik N,Binder C

doi

10.1088/0967-3334/35/7/1349

subject

Has Abstract

pub_date

2014-07-01 00:00:00

pages

1349-55

issue

7

eissn

0967-3334

issn

1361-6579

journal_volume

35

pub_type

杂志文章
  • The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise.

    abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/5/008

    authors: Wang L,Poon CC,Zhang YT

    更新日期:2010-05-01 00:00:00

  • Wavelet bidomain sample entropy analysis to predict spontaneous termination of atrial fibrillation.

    abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/1/005

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-01-01 00:00:00

  • Age-related changes in pulse risetime measured by multi-site photoplethysmography.

    abstract:OBJECTIVE:It is accepted that changes in the peripheral pulse waveform characteristics occur with ageing. Pulse risetime is one important feature which has clinical value. However, it is unclear how it varies across the full age spectrum from child to senior and for different peripheral measurement sites. The objective...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9b67

    authors: Allen J,O'Sullivan J,Stansby G,Murray A

    更新日期:2020-08-11 00:00:00

  • Wearable oxygen uptake and energy expenditure monitors.

    abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab3827

    authors: Tamura T

    更新日期:2019-09-03 00:00:00

  • Real time impedance plots with arbitrary frequency components.

    abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/1/008

    authors: Searle A,Kirkup L

    更新日期:1999-02-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • Ballistocardiography and seismocardiography detection of hemodynamic changes during simulated obstructive apnea.

    abstract:OBJECTIVE:To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS:Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab924b

    authors: Morra S,Hossein A,Gorlier D,Rabineau J,Chaumont M,Migeotte PF,Van De Borne P

    更新日期:2020-07-09 00:00:00

  • A clinical distortion index for compressed echocardiogram evaluation: recommendations for Xvid codec.

    abstract::This paper introduces a new clinical distortion index able to measure the decrease in diagnostic content in compressed echocardiograms. It is calculated using cardiologists' answers to a clinical testbed composed of two types of tests: one blind and the other semi-blind. This index may be used to compare clinical perf...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/5/001

    authors: Alesanco A,Hernández C,Portolés A,Ramos L,Aured C,García M,Serrano P,García J

    更新日期:2009-05-01 00:00:00

  • Effect of lower body negative pressure and gravity on regional lung ventilation determined by EIT.

    abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/003

    authors: Frerichs I,Bodenstein M,Dudykevych T,Hinz J,Hahn G,Hellige G

    更新日期:2005-04-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

    abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2/002

    authors: Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

    更新日期:1994-05-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms.

    abstract::The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/1/318

    authors: Al Hatib F,Trendafilova E,Daskalov I

    更新日期:2000-02-01 00:00:00

  • Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab7ac

    authors: Ivanović MD,Petrovic J,Savić A,Gligorić G,Miletić M,Vukčević M,Bojović B,Hadžievski L,Allsop T,Webb DJ

    更新日期:2018-04-26 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.

    abstract:OBJECTIVE:Currently, continuous blood pressure (BP) measurements are mostly based on multi-sensor combinations and datasets with limited BP ranges. Besides, most BP-related features derive from the photoplethysmogram (PPG) signal. The mechanism of PPG signal formation is not considered. We aimed to design a noninvasive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc8dd

    authors: Hu Q,Deng X,Wang A,Yang C

    更新日期:2021-01-01 00:00:00

  • Single-sector thermophysiological human simulator.

    abstract::Thermal sweating manikins are used to analyse the heat and mass transfer phenomena in the skin-clothing-environment system. However, the limiting factor of present thermal manikins is their inability to simulate adequately the human thermal behaviour, which has a significant effect on the clothing microenvironment. A ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/2/002

    authors: Psikuta A,Richards M,Fiala D

    更新日期:2008-02-01 00:00:00

  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • An automated quasi-continuous capillary refill timing device.

    abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/83

    authors: Blaxter LL,Morris DE,Crowe JA,Henry C,Hill S,Sharkey D,Vyas H,Hayes-Gill BR

    更新日期:2016-01-01 00:00:00

  • Multimodal heart beat detection using signal quality indices.

    abstract::The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure ca...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/8/1665

    authors: Johnson AE,Behar J,Andreotti F,Clifford GD,Oster J

    更新日期:2015-08-01 00:00:00

  • Non-constrained monitoring of systolic blood pressure on a weighing scale.

    abstract::In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured usin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/011

    authors: Shin JH,Lee KM,Park KS

    更新日期:2009-07-01 00:00:00

  • Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1435

    authors: Di Marco LY,Duan W,Bojarnejad M,Zheng D,King S,Murray A,Langley P

    更新日期:2012-09-01 00:00:00

  • The feasibility of transoesophageal bioimpedance measurements for the detection of heart graft rejection.

    abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S10

    authors: Giovinazzo G,Ribas N,Cinca J,Rosell-Ferrer J

    更新日期:2011-07-01 00:00:00

  • Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients.

    abstract::A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes cl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/11/1931

    authors: Schwenk M,Gogulla S,Englert S,Czempik A,Hauer K

    更新日期:2012-11-01 00:00:00

  • Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs.

    abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1439

    authors: Svenmarker S,Häggmark S,Johansson G,Axelsson B,Wiklund U,Haney M

    更新日期:2014-07-01 00:00:00

  • Modelling of the immunoassay element of an optical immunosensor.

    abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/318

    authors: Keating SM,Flanagan MT

    更新日期:2001-08-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Improved ultrasound transducer positioning by fetal heart location estimation during Doppler based heart rate measurements.

    abstract:OBJECTIVE:Doppler ultrasound (US) is the most commonly applied method to measure the fetal heart rate (fHR). When the fetal heart is not properly located within the ultrasonic beam, fHR measurements often fail. As a consequence, clinical staff need to reposition the US transducer on the maternal abdomen, which can be a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa8a1a

    authors: Hamelmann P,Vullings R,Schmitt L,Kolen AF,Mischi M,van Laar JOEH,Bergmans JWM

    更新日期:2017-09-21 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00