Abstract:
:The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure can result in poor delineation of the R peak, use of synchronously measured signals could allow for resolution of the R peak even scenarios with poor quality ECG recordings. Robust estimation of R peak locations from multimodal signals facilitates real time monitoring and is likely to reduce false alarms due to inaccurate derived parameters.We propose a method which fuses R peaks detected on the ECG using an energy detector with those detected on the arterial blood pressure (ABP) waveform using the length transform. A signal quality index (SQI) for the two signals is then derived. The ECG SQI is based upon the agreement between two distinct peak detectors. The ABP SQI estimates the blood pressure at various phases in the cardiac cycle and only accepts the signal as good quality if the values are physiologically plausible. Detections from these two signals were merged by selecting the R peak detections from the signal with a higher SQI. The approach presented in this paper was evaluated on datasets provided for the Physionet/Computing in Cardiology Challenge 2014. The algorithm achieved a sensitivity of 95.1% and positive predictive value of 89.3% on an external evaluation set, and achieved a score of 91.5%.The method here demonstrated excellent performance across a variety of signal morphologies collected during clinical practice. Fusion of R peaks from other signals has the potential to provide informed estimates of the R peak location in situations where the ECG is noisy or completely absent. Source code for the algorithm is made available freely online.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Johnson AE,Behar J,Andreotti F,Clifford GD,Oster Jdoi
10.1088/0967-3334/36/8/1665subject
Has Abstractpub_date
2015-08-01 00:00:00pages
1665-77issue
8eissn
0967-3334issn
1361-6579journal_volume
36pub_type
杂志文章abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2/002
更新日期:1994-05-01 00:00:00
abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/8/1273
更新日期:2016-08-01 00:00:00
abstract::Balance is the ability to maintain equilibrium while sitting or standing. There are a number of different methods which are used to assess balance: technical methods such as sway magnetometry, ataxia meter and force platforms, and clinical methods such as the functional reach test, Berg balance test and fall risk inde...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/4/309
更新日期:2000-11-01 00:00:00
abstract::Health is one of the most important non-material assets and thus also has an enormous influence on material values, since treating and preventing diseases is expensive. The number one cause of death worldwide today originates in cardiovascular diseases. For these reasons the aim of understanding the functions and the ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/37/5/R46
更新日期:2016-05-01 00:00:00
abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/001
更新日期:1994-05-01 00:00:00
abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/2/303
更新日期:2000-05-01 00:00:00
abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaaaa0
更新日期:2018-02-28 00:00:00
abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aae625
更新日期:2018-10-30 00:00:00
abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1491
更新日期:2012-09-01 00:00:00
abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/6/007
更新日期:2011-06-01 00:00:00
abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/026
更新日期:1996-11-01 00:00:00
abstract::Focused impedance measurements (FIM) are used in several fields, and address the problem of measuring the volume impedance of an object within a volume conductor. Several electrode configurations are possible, and these have different properties. Sensitivity fields of four configurations have been investigated. We pre...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/6/1067
更新日期:2014-06-01 00:00:00
abstract:OBJECTIVE:Brain waves vary between people. This work aims to improve automatic sleep staging for longitudinal sleep monitoring via personalization of algorithms based on individual characteristics extracted from sleep data recorded during the first night. APPROACH:As data from a single night are very small, thereby ma...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab921e
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVE:Currently, continuous blood pressure (BP) measurements are mostly based on multi-sensor combinations and datasets with limited BP ranges. Besides, most BP-related features derive from the photoplethysmogram (PPG) signal. The mechanism of PPG signal formation is not considered. We aimed to design a noninvasive...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abc8dd
更新日期:2021-01-01 00:00:00
abstract::Plethysmographic measurement of airway resistance (R(aw)) has been determined by single-point analysis, usually at 50% of maximum inspiratory flow (MIF). Computer-assisted (best fit) analysis, however, allows R(aw) to be calculated by applying a regression line to any portion of the plethysmograph pressure-flow loop. ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/2/304
更新日期:2002-05-01 00:00:00
abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/N61
更新日期:2015-03-01 00:00:00
abstract::The relation between the right-side (RS) electrical impedance phase angle (PA) and segmental PA in five configurations at 50 kHz was analyzed in 23 peritoneal dialysis male patients before complete drainage of the abdominal cavity. The impedance vector (Z/H) components were standardized by the height H of the subjects...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/9/N01
更新日期:2008-09-01 00:00:00
abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/1/31
更新日期:2014-01-01 00:00:00
abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/27/3/002
更新日期:2006-03-01 00:00:00
abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/29/6/S29
更新日期:2008-06-01 00:00:00
abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/5/967
更新日期:2015-05-01 00:00:00
abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/030
更新日期:2004-02-01 00:00:00
abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/303
更新日期:2001-02-01 00:00:00
abstract::A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three con...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/1/308
更新日期:2003-02-01 00:00:00
abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/1361-6579/aab2ef
更新日期:2018-04-20 00:00:00
abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aab7ac
更新日期:2018-04-26 00:00:00
abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aace95
更新日期:2018-07-16 00:00:00
abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/308
更新日期:2001-02-01 00:00:00
abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/aa5fca
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVE:This paper aims to present how physiological signals can be processed based on wavelet decomposition to calculate multiple physiological parameters in real-time on an embedded platform. APPROACH:An ECG and PPG are decomposed to the appropriate scale based on a quadratic spline wavelet base in order to obtain...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab6f52
更新日期:2020-03-06 00:00:00