Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

Abstract:

:ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. In addition there arises an increase in p' in early systole towards the periphery of the lung. Frequency behaviour of p' changes with location. At all times after the R-wave, in the centre of the lung p' is higher at higher frequency f whereas in the periphery it is lower at higher f. The principal decrease in p' can be explained by increasing pulmonary blood volume due to cardiac contraction. The early systolic increase is presumably due to venous return to the left atrium locally leading blood output from the right ventricle which is delayed by the windkessel effect. Based on a model taking extracapillary and capillary blood volume increase into account, the change in frequency behaviour of p' is explained by regional variations in extracapillary blood vessel size determining the relative contributions of extracapillary blood volume and capillary blood volume change to p' at a certain frequency.

journal_name

Physiol Meas

authors

Nopp P,Zhao TX,Brown BH,Wang W

doi

10.1088/0967-3334/17/4a/026

subject

Has Abstract

pub_date

1996-11-01 00:00:00

pages

A213-25

eissn

0967-3334

issn

1361-6579

journal_volume

17 Suppl 4A

pub_type

杂志文章
  • Electroencephalography as a predictor of self-report fatigue/sleepiness during monotonous driving in train drivers.

    abstract:OBJECTIVE:In this study, electroencephalography activity recorded during monotonous driving was investigated to examine the predictive capability of monopolar EEG analysis for fatigue/sleepiness in a cohort of train drivers. APPROACH:Sixty-three train drivers participated in the study, where 32- lead monopolar EEG dat...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae42e

    authors: Lees T,Chalmers T,Burton D,Zilberg E,Penzel T,Lal S,Lal S

    更新日期:2018-10-30 00:00:00

  • Pulmonary perfusion measured by means of electrical impedance tomography.

    abstract::Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/2/013

    authors: Vonk Noordegraaf A,Kunst PW,Janse A,Marcus JT,Postmus PE,Faes TJ,de Vries PM

    更新日期:1998-05-01 00:00:00

  • Effect of organic and inorganic nitrates on cerebrovascular pulsatile power transmission in patients with heart failure and preserved ejection fraction.

    abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1361-6579/aab2ef

    authors: Londono-Hoyos F,Zamani P,Beraun M,Vasim I,Segers P,Chirinos JA

    更新日期:2018-04-20 00:00:00

  • Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation.

    abstract:OBJECTIVE:The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation. APPROACH:Twenty-four consecutive patients requiring intubation with a double-lumen tube and subs...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaeb2

    authors: Zhao Z,Wang W,Zhang Z,Xu M,Frerichs I,Wu J,Moeller K

    更新日期:2018-03-29 00:00:00

  • Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats--a pilot study.

    abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/010

    authors: Huang YJ,Huang EY,Lu YY,Chen CY,Cheng KS

    更新日期:2011-09-01 00:00:00

  • Treading on the unknown-the feasibility of a novel approach to investigating the motor control of walking.

    abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/1361-6579/aab659

    authors: Koren Y,Raanan Y,Parmet Y,Bar-Haim S

    更新日期:2018-04-26 00:00:00

  • The influence of cardiac preload and positive end-expiratory pressure on the pre-ejection period.

    abstract::The pre-ejection period (PEP) has recently been described as a potential parameter for monitoring cardiac preload. This study further investigated the influence of changes in intravascular volume status and the application of positive end-expiratory pressure (PEEP) on the pre-ejection period. In ten pigs, ECG, arteria...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/012

    authors: Kubitz JC,Kemming GI,Schultheib G,Starke J,Podtschaske A,Goetz AE,Reuter DA

    更新日期:2005-12-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Novel technology to help understand the context of physical activity and sedentary behaviour.

    abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1834

    authors: Loveday A,Sherar LB,Sanders JP,Sanderson PW,Esliger DW

    更新日期:2016-10-01 00:00:00

  • Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms.

    abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/357

    authors: Patterson RP,Zhang J

    更新日期:2003-05-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.

    abstract:OBJECTIVE:Currently, continuous blood pressure (BP) measurements are mostly based on multi-sensor combinations and datasets with limited BP ranges. Besides, most BP-related features derive from the photoplethysmogram (PPG) signal. The mechanism of PPG signal formation is not considered. We aimed to design a noninvasive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc8dd

    authors: Hu Q,Deng X,Wang A,Yang C

    更新日期:2021-01-01 00:00:00

  • A shape-based quality evaluation and reconstruction method for electrical impedance tomography.

    abstract::Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1161

    authors: Antink CH,Pikkemaat R,Malmivuo J,Leonhardt S

    更新日期:2015-06-01 00:00:00

  • Impedance analyser module for EIT and spectroscopy using undersampling.

    abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/303

    authors: Dudykevych T,Gersing E,Thiel F,Hellige G

    更新日期:2001-02-01 00:00:00

  • A finite element model of needle electrode spatial sensitivity.

    abstract::We used the finite element (FE) method to estimate the spatial sensitivity of a needle electrode for bioimpedance measurements. This current conducting needle with an insulated shaft was inserted in a saline solution and the current was measured at the neutral electrode. Model resistance and reactance were calculated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/006

    authors: Høyum P,Kalvøy H,Martinsen ØG,Grimnes S

    更新日期:2010-10-01 00:00:00

  • 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approach.

    abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/012

    authors: Morucci JP,Granié M,Lei M,Chabert M,Marsili PM

    更新日期:1995-08-01 00:00:00

  • Video rate electrical impedance tomography of vascular changes: preclinical development.

    abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/3/006

    authors: Halter R,Hartov A,Paulsen K

    更新日期:2008-03-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

    abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/022

    authors: Andersson N,Malm J,Bäcklund T,Eklund A

    更新日期:2005-12-01 00:00:00

  • The influence of dilution on the offline measurement of exhaled nitric oxide.

    abstract:OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The internati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa455

    authors: MacBean V,Pooranampillai D,Howard C,Lunt A,Greenough A

    更新日期:2018-02-26 00:00:00

  • Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab7ac

    authors: Ivanović MD,Petrovic J,Savić A,Gligorić G,Miletić M,Vukčević M,Bojović B,Hadžievski L,Allsop T,Webb DJ

    更新日期:2018-04-26 00:00:00

  • An automated quasi-continuous capillary refill timing device.

    abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/83

    authors: Blaxter LL,Morris DE,Crowe JA,Henry C,Hill S,Sharkey D,Vyas H,Hayes-Gill BR

    更新日期:2016-01-01 00:00:00

  • Potential neuroprotective effects of acupuncture stimulation on diabetes mellitus in a global ischemic rat model.

    abstract::Acupuncture (ACU) is known to be effective in ischemia treatment, and glutamate (GLU) excitotoxicity is an important factor in neuronal cell death. We observed the effect of ACU on cerebral blood flow (%CBF) and DeltaGLU (the changes in GLU release) in the ischemic stroke rat model of diabetic mellitus (DM). A global ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/5/003

    authors: Choi S,Lee GJ,Chae SJ,Kang SW,Yin CS,Lee SH,Choi SK,Park HK

    更新日期:2010-05-01 00:00:00

  • Wavelet bidomain sample entropy analysis to predict spontaneous termination of atrial fibrillation.

    abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/1/005

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-01-01 00:00:00

  • Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs.

    abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1273

    authors: Krasteva V,Jekova I,Leber R,Schmid R,Abächerli R

    更新日期:2016-08-01 00:00:00

  • Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

    abstract::A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/4/010

    authors: Hovorka R,Canonico V,Chassin LJ,Haueter U,Massi-Benedetti M,Orsini Federici M,Pieber TR,Schaller HC,Schaupp L,Vering T,Wilinska ME

    更新日期:2004-08-01 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/9/1624

    authors: Gade J,Greisen G

    更新日期:2016-09-01 00:00:00

  • Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG.

    abstract:OBJECTIVE:To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND:Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physic...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840a

    authors: Kinnunen H,Rantanen A,Kenttä T,Koskimäki H

    更新日期:2020-05-07 00:00:00