Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

Abstract:

:The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguide technique measures only in the most superficial capillaries. Laser Doppler flux (LDF) and transcutaneous oxygen (tcpO2) measurements were also obtained concurrently. At the height of the reaction, heating did not significantly change SO2 or LDF, showing that the vessels in the skin were maximally vasodilated. Although SO2 was increased in the reaction, tcpO2 decreased. This suggests that the infiltrating cells may present a diffusion barrier to oxygen between the capillaries and the tissue cells. This study has shown that micro-lightguide spectrophotometry gives a local picture of intracapillary oxygen supply, which is useful in elucidating the pathophysiological changes occurring during chronic inflammation.

journal_name

Physiol Meas

authors

Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

doi

10.1088/0967-3334/15/2/002

subject

Has Abstract

pub_date

1994-05-01 00:00:00

pages

115-28

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

15

pub_type

杂志文章
  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in rats.

    abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/2/004

    authors: Hsiu H,Jan MY,Wang WK,Wang YY

    更新日期:2006-02-01 00:00:00

  • Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population.

    abstract:OBJECTIVE:Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals' short biologic half-lives, shipping and storage requirement...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aad947

    authors: Specht AJ,Kponee K,Nkpaa KW,Balcom PH,Weuve J,Nie LH,Weisskopf MG

    更新日期:2018-08-31 00:00:00

  • The effect of persistent U-shaped patterns in RR night-time series on the heart rate variability complexity in healthy humans.

    abstract:OBJECTIVE:U-shaped patterns, characteristic periods of time observed in tachograms, are a specific subgroup among very low frequency components characterized by relatively short periods of smooth accelerations followed by decelerations of heart rhythm. In this study, we characterize this phenomenon and its effect on he...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9376

    authors: Soliński M,Kuklik P,Gierałtowski J,Baranowski R,Graff B,Żebrowski J

    更新日期:2020-07-02 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Measurement of pupil reactivity using fast pupillometry.

    abstract::Analysis of human eye pupil reactivity is a very valuable diagnostic method used mainly for evaluation of the condition of the autonomic nervous system and the visual system. The paper presents an experimental pupillometer built in the Institute of Physics of the Wroclaw University of Technology. The apparatus makes i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/1/006

    authors: Hachol A,Szczepanowska-Nowak W,Kasprzak H,Zawojska I,Dudzinski A,Kinasz R,Wygledowska-Promienska D

    更新日期:2007-01-01 00:00:00

  • Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

    abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/040

    authors: Ahadzi GM,Liston AD,Bayford RH,Holder DS

    更新日期:2004-02-01 00:00:00

  • Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats--a pilot study.

    abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/010

    authors: Huang YJ,Huang EY,Lu YY,Chen CY,Cheng KS

    更新日期:2011-09-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Exposure to light and darkness and its influence on physiological measures of intensive care unit patients-a systematic literature review.

    abstract::Sleep-wake patterns are often significantly disturbed in critically ill patients. This disturbance is closely linked to secondary brain dysfunctions in these patients. Sedation not only impairs sleep quality in ICU patients but also has detrimental effects on short- and long-term outcome. In other contexts, light ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/37/9/R73

    authors: Weiss B,Spies C,Piazena H,Penzel T,Fietze I,Luetz A

    更新日期:2016-09-01 00:00:00

  • Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    abstract::This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital ausculta...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/1163

    authors: Riknagel D,Dinesen B,Zimmermann H,Farlie R,Schmidt S,Toft E,Struijk JJ

    更新日期:2016-07-01 00:00:00

  • Specific heat capacity of freshly excised prostate specimens.

    abstract::The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 3...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/11/N02

    authors: Patch SK,Rao N,Kelly H,Jacobsohn K,See WA

    更新日期:2011-11-01 00:00:00

  • In vivo measurement of human skin absorption of topically applied substances by a photoacoustic technique.

    abstract::A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/3/304

    authors: Gutiérrez-Juárez G,Vargas-Luna M,Córdova T,Varela JB,Bernal-Alvarado JJ,Sosa M

    更新日期:2002-08-01 00:00:00

  • Comprehensive analysis of cardiac health using heart rate signals.

    abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/5/005

    authors: Acharya U R,Kannathal N,Krishnan SM

    更新日期:2004-10-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using an adaptive observer--experimental and clinical evaluation.

    abstract::Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have draw...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/11/003

    authors: Andersson K,Manchester IR,Andersson N,Shiriaev A,Malm J,Eklund A

    更新日期:2007-11-01 00:00:00

  • Thermography and colour duplex ultrasound assessments of arterio-venous fistula function in renal patients.

    abstract::Vascular and clinical assessments of arterio-venous fistula (AVF) function and access are important in patients undergoing or preparing to undergo renal dialysis. Objective assessment techniques include colour duplex ultrasound and more recently medical infrared thermography. Ideally, these should help assess problems...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/1/005

    authors: Allen J,Oates CP,Chishti AD,Ahmed IA,Talbot D,Murray A

    更新日期:2006-01-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • Hemodynamic evaluation in pregnancy: limitations of impedance cardiography.

    abstract::Impedance cardiography (ICG) has been proposed to estimate the stroke volume (SV) and cardiac output (CO) in various medical indications. The aim of this study was to explore the reliability of ICG during pregnancy with respect to SV and CO measurements. Blood pressure, heart rate and thoracic impedance were monitored...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/6/1015

    authors: Moertl MG,Schlembach D,Papousek I,Hinghofer-Szalkay H,Weiss EM,Lang U,Lackner HK

    更新日期:2012-06-01 00:00:00

  • Automatic detection of detached and erroneous electrodes in electrical impedance tomography.

    abstract::One unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper presents an automatic approach to detect such erroneous electrodes. It is based on the assumption that all valid m...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/2/017

    authors: Asfaw Y,Adler A

    更新日期:2005-04-01 00:00:00

  • An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallers.

    abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/009

    authors: Weiss A,Herman T,Plotnik M,Brozgol M,Giladi N,Hausdorff JM

    更新日期:2011-12-01 00:00:00

  • Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.

    abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/3/L1

    authors: Anagnostopoulou P,Egger B,Lurà M,Usemann J,Schmidt A,Gorlanova O,Korten I,Roos M,Frey U,Latzin P

    更新日期:2016-03-01 00:00:00

  • A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.

    abstract:OBJECTIVE:Currently, continuous blood pressure (BP) measurements are mostly based on multi-sensor combinations and datasets with limited BP ranges. Besides, most BP-related features derive from the photoplethysmogram (PPG) signal. The mechanism of PPG signal formation is not considered. We aimed to design a noninvasive...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc8dd

    authors: Hu Q,Deng X,Wang A,Yang C

    更新日期:2021-01-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1149

    authors: Khor JM,Tizzard A,Demosthenous A,Bayford R

    更新日期:2014-06-01 00:00:00

  • Magnetographic assessment of fetal hiccups and their effect on fetal heart rhythm.

    abstract::Fetal hiccups emerge as early as nine weeks post-conception, being the predominant diaphragmatic movement before 26 weeks of gestation. They are considered as a programmed isometric inspiratory muscle exercise of the fetus in preparation for the post-natal respiratory function, or a manifestation of a reflex circuitry...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/6/005

    authors: Popescu EA,Popescu M,Bennett TL,Lewine JD,Drake WB,Gustafson KM

    更新日期:2007-06-01 00:00:00

  • Network proteomics of human dermal wound healing.

    abstract:OBJECTIVE:The healing of wounds is critical in protecting the human body against environmental factors. The mechanisms involving protein expression during this complex physiological process have not been fully elucidated. APPROACH:Here, we use reverse-phase protein microarrays (RPPA) involving 94 phosphoproteins to st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaee19

    authors: Gao X,Petricoin EF 3rd,Ward KR,Goldberg SR,Duane TM,Bonchev D,Arodz T,Diegelmann RF

    更新日期:2018-12-07 00:00:00

  • Comparison of four different FIM configurations--a simulation study.

    abstract::Focused impedance measurements (FIM) are used in several fields, and address the problem of measuring the volume impedance of an object within a volume conductor. Several electrode configurations are possible, and these have different properties. Sensitivity fields of four configurations have been investigated. We pre...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1067

    authors: Pettersen FJ,Ferdous H,Kalvøy H,Martinsen ØG,Høgetveit JO

    更新日期:2014-06-01 00:00:00

  • Assessment of cerebrospinal fluid outflow conductance using constant-pressure infusion--a method with real time estimation of reliability.

    abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/022

    authors: Andersson N,Malm J,Bäcklund T,Eklund A

    更新日期:2005-12-01 00:00:00

  • Classification of glucose concentration in diluted urine using the low-resolution Raman spectroscopy and kernel optimization methods.

    abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/5/011

    authors: Park C,Kim K,Choi J,Park K

    更新日期:2007-05-01 00:00:00