Assessment of cerebrospinal fluid outflow conductance using an adaptive observer--experimental and clinical evaluation.

Abstract:

:Idiopathic normal pressure hydrocephalus (INPH) patients have a disturbance in the dynamics of the cerebrospinal fluid (CSF) system. The outflow conductance, C, of the CSF system has been suggested to be prognostic for positive outcome after treatment with a CSF shunt. All current methods for estimation of C have drawbacks; these include lack of information on the accuracy and relatively long investigation times. Thus, there is a need for improved methods. To accomplish this, the theoretical framework for a new adaptive observer (OBS) was developed which provides real-time estimation of C. The aim of this study was to evaluate the OBS method and to compare it with the constant pressure infusion (CPI) method. The OBS method was applied to data from infusion investigations performed with the CPI method. These consisted of repeated measurements on an experimental set-up and 30 patients with suspected INPH. There was no significant difference in C between the CPI and the OBS method for the experimental set-up. For the patients there was a significant difference, -0.84+/-1.25 microl (s kPa)(-1), mean +/- SD (paired sample t-test, p<0.05). However, such a difference is within clinically acceptable limits. This encourages further development of this new real-time approach for estimation of the outflow conductance.

journal_name

Physiol Meas

authors

Andersson K,Manchester IR,Andersson N,Shiriaev A,Malm J,Eklund A

doi

10.1088/0967-3334/28/11/003

subject

Has Abstract

pub_date

2007-11-01 00:00:00

pages

1355-68

issue

11

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(07)52766-8

journal_volume

28

pub_type

杂志文章
  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • Development of a noncontact heart rate monitoring system for sedentary behavior based on an accelerometer attached to a chair.

    abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/3/N61

    authors: Lim E,Lee HK,Myoung HS,Lee KJ

    更新日期:2015-03-01 00:00:00

  • Topographic distribution of idiopathic pulmonary fibrosis: a hybrid physics- and agent-based model.

    abstract:OBJECTIVE:Idiopathic pulmonary fibrosis (IPF) is a progressive and fatal disease characterized by excessive deposition of collagen and associated stiffening of lung tissue. While it is known that inflammation and dysfunction of fibroblasts are involved in disease development, it remains poorly understood how cells and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaca86

    authors: Wellman TJ,Mondoñedo JR,Davis GS,Bates JHT,Suki B

    更新日期:2018-06-28 00:00:00

  • Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm.

    abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/27/3/002

    authors: Tarvainen MP,Georgiadis SD,Ranta-Aho PO,Karjalainen PA

    更新日期:2006-03-01 00:00:00

  • Validity of an activity monitor in young people with cerebral palsy gross motor function classification system level I.

    abstract::The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, wa...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/11/2307

    authors: O' Donoghue D,Kennedy N

    更新日期:2014-11-01 00:00:00

  • Measuring the rate of change of haemodynamic response at the onset of exercise in normal limbs and those with intermittent claudication.

    abstract::Patients with claudication have an inadequate haemodynamic response to exercise. Blood flow response will not only have a magnitude, but also a rate of change. There is scope for investigating these parameters, as manipulation of the factors which control them may benefit work to improve the treatment for claudication...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/6/002

    authors: Meeson S,Srodon PD

    更新日期:2005-12-01 00:00:00

  • An intelligent ventilation and oxygenation management system in neonatal intensive care using fuzzy trend template fitting.

    abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/019

    authors: Belal SY,Taktak AF,Nevill A,Spencer A

    更新日期:2005-08-01 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • EIT data noise evaluation in the clinical environment.

    abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/006

    authors: Meeson S,Blott BH,Killingback AL

    更新日期:1996-11-01 00:00:00

  • Fetal motion estimation from noninvasive cardiac signal recordings.

    abstract::Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Dopp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/11/2003

    authors: Biglari H,Sameni R

    更新日期:2016-11-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study.

    abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/008

    authors: King J,Mochalski P,Kupferthaler A,Unterkofler K,Koc H,Filipiak W,Teschl S,Hinterhuber H,Amann A

    更新日期:2010-09-01 00:00:00

  • Triple-frequency method for measuring blood impedance.

    abstract::A method was developed for simultaneously measuring plasma resistance, cell interior resistance and cell membrane capacitance of blood. A three-element circuit model for simulating the impedance of blood was evaluated by comparing measured and calculated impedance frequency curves and was found feasible. The values of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/2/006

    authors: Zhao TX,Jacobson B,Ribbe T

    更新日期:1993-05-01 00:00:00

  • The influence of cardiac preload and positive end-expiratory pressure on the pre-ejection period.

    abstract::The pre-ejection period (PEP) has recently been described as a potential parameter for monitoring cardiac preload. This study further investigated the influence of changes in intravascular volume status and the application of positive end-expiratory pressure (PEEP) on the pre-ejection period. In ten pigs, ECG, arteria...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/012

    authors: Kubitz JC,Kemming GI,Schultheib G,Starke J,Podtschaske A,Goetz AE,Reuter DA

    更新日期:2005-12-01 00:00:00

  • Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1035

    authors: Grychtol B,Adler A

    更新日期:2014-06-01 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00

  • Localization of sources of brain alpha/theta/delta activity and the influence of the mode of spontaneous mentation.

    abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4a/004

    authors: Michel CM,Henggeler B,Brandeis D,Lehmann D

    更新日期:1993-11-01 00:00:00

  • Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

    abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/040

    authors: Ahadzi GM,Liston AD,Bayford RH,Holder DS

    更新日期:2004-02-01 00:00:00

  • 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approach.

    abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/012

    authors: Morucci JP,Granié M,Lei M,Chabert M,Marsili PM

    更新日期:1995-08-01 00:00:00

  • The T-SCAN technology: electrical impedance as a diagnostic tool for breast cancer detection.

    abstract::In this paper we present the T-SCAN technology and its use as a diagnostic tool for breast cancer detection. We show, using theoretical models with simplified geometries, that displaying planar two-dimensional maps of the currents detected at the breast's surface relate to the electric field distribution within the br...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/301

    authors: Assenheimer M,Laver-Moskovitz O,Malonek D,Manor D,Nahaliel U,Nitzan R,Saad A

    更新日期:2001-02-01 00:00:00

  • Variability in estimating shunt from single pulse oximetry measurements.

    abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/967

    authors: Karlen W,Petersen CL,Dumont GA,Ansermino JM

    更新日期:2015-05-01 00:00:00

  • Invasive and noninvasive means of measuring intracranial pressure: a review.

    abstract::Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space ar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa7256

    authors: Zhang X,Medow JE,Iskandar BJ,Wang F,Shokoueinejad M,Koueik J,Webster JG

    更新日期:2017-07-24 00:00:00

  • Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1149

    authors: Khor JM,Tizzard A,Demosthenous A,Bayford R

    更新日期:2014-06-01 00:00:00

  • Fractal analysis of foetal heart rate variability.

    abstract::Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dime...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/3/009

    authors: Gough NA

    更新日期:1993-08-01 00:00:00

  • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/026

    authors: Nopp P,Zhao TX,Brown BH,Wang W

    更新日期:1996-11-01 00:00:00

  • A pH-mucosa area unit of measure to consider morphology of the oesophagus when evaluating oesophagitis.

    abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/4/006

    authors: Haylett KR,Vales P,Lee SH,McCloy RF

    更新日期:2003-11-01 00:00:00

  • Combined electrocardiogram and photoplethysmogram measurements as an indicator of objective sleepiness.

    abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/8/001

    authors: Chua CP,McDarby G,Heneghan C

    更新日期:2008-08-01 00:00:00