Abstract:
:Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field complex elicited by electrical stimulation of the auditory nerve as well as the distribution of the magnetic responses over the head resemble that of auditory-evoked fields elicited by acoustic stimulation of normal subjects. The location and direction of the equivalent dipole are consistent with activation of the auditory cortex. Neuromagnetic recordings could be used in the future (i) to check activation of the auditory cortices in cochlear-implant patients; (ii) to gather information about the functional properties of this activity, and (iii) to study the integrity of central auditory pathways in totally deaf patients.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Pelizzone Mdoi
10.1088/0967-3334/14/4a/014subject
Has Abstractpub_date
1993-11-01 00:00:00pages
A81-4eissn
0967-3334issn
1361-6579journal_volume
14 Suppl 4Apub_type
杂志文章,评审abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa74d
更新日期:2018-02-28 00:00:00
abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/318
更新日期:2001-08-01 00:00:00
abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/3/L1
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac553
更新日期:2018-06-19 00:00:00
abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/28/2/007
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVE:In this research, we introduce a new methodology for atrial fibrillation (AF) diagnosis during sleep in a large population sample at risk of sleep-disordered breathing. APPROACH:The approach leverages digital biomarkers and recent advances in machine learning (ML) for mass AF diagnosis from overnight-hours o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abb8bf
更新日期:2020-11-06 00:00:00
abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/3/006
更新日期:2009-03-01 00:00:00
abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/12/F01
更新日期:2011-12-01 00:00:00
abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/4/N01
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVE:To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS:Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab924b
更新日期:2020-07-09 00:00:00
abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/8/1335
更新日期:2012-08-01 00:00:00
abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/17/4a/006
更新日期:1996-11-01 00:00:00
abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/8/001
更新日期:2008-08-01 00:00:00
abstract::Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule in...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1197
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab0daa
更新日期:2019-04-03 00:00:00
abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/2/009
更新日期:2005-04-01 00:00:00
abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/7/012
更新日期:2010-07-01 00:00:00
abstract::False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/8/1298
更新日期:2016-08-01 00:00:00
abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/0967-3334/27/4/005
更新日期:2006-04-01 00:00:00
abstract::Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when rec...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/32/10/002
更新日期:2011-10-01 00:00:00
abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/12/005
更新日期:2010-12-01 00:00:00
abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/6/1035
更新日期:2014-06-01 00:00:00
abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/3/309
更新日期:2003-08-01 00:00:00
abstract::During anaesthesia awareness and nociception are serious complications that may further lead to haemodynamic instability. Specific monitoring of depth of hypnosis and depth of analgesia based on heart rate variability (HRV) analysis is eligible to improve patient safety and reduce efforts in post-operative care. Conse...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/33/2/207
更新日期:2012-02-01 00:00:00
abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1669
更新日期:2016-10-01 00:00:00
abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/29/6/S29
更新日期:2008-06-01 00:00:00
abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaaaa0
更新日期:2018-02-28 00:00:00
abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab921d
更新日期:2020-06-30 00:00:00
abstract::A multi-frequency electrical impedance tomography system for cardiopulmonary monitoring has been designed with specialized digital signal processors developed primarily for the telecommunications sector. The system consists of two modules: a scan-head and a base-station. The scan-head, located close to the patient's t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/6/S04
更新日期:2009-06-01 00:00:00
abstract::Monitoring the brain state in anaesthesia is crucial for clinical doctors. In this study, we propose a novel nonlinear method, the permutation Lempel-Ziv complexity (PLZC) index, which describes the complexity in the electroencephalographic (EEG) signal to quantify the effect of GABAergic anaesthetics on brain activit...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/12/2483
更新日期:2015-12-01 00:00:00