Abstract:
:A multi-frequency electrical impedance tomography system for cardiopulmonary monitoring has been designed with specialized digital signal processors developed primarily for the telecommunications sector. The system consists of two modules: a scan-head and a base-station. The scan-head, located close to the patient's torso, contains front-end circuits for measuring transfer impedance with a 16-electrode array. The base-station, placed at the bedside, comprises 16 direct digital synthesizers, 32 digital down-converters, digital circuits to control the data acquisition sequence and a USB-2.0 microcontroller. At every step of the scan sequence, the system simultaneously measures four complex variables at eight frequencies. These variables are the potential difference between the selected pair of sense electrodes, the currents applied by the source and sink electrodes, and the current flowing through the ground electrode. Frequencies are programmable from 10 kHz to 2 MHz with a resolution of 2 mHz. Characterization tests were performed with a precision mesh phantom connected to the scan-head. For a 5 Hz frame rate, the mean signal-to-noise ratio and accuracy are, respectively, 43 dB and 95.4% for eight frequencies logarithmically spaced from 70 to 950 kHz. In vitro and in vivo time-difference images have been reconstructed.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Robitaille N,Guardo R,Maurice I,Hartinger AE,Gagnon Hdoi
10.1088/0967-3334/30/6/S04subject
Has Abstractpub_date
2009-06-01 00:00:00pages
S57-71issue
6eissn
0967-3334issn
1361-6579pii
S0967-3334(09)00941-1journal_volume
30pub_type
杂志文章abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/1361-6579/aab2ef
更新日期:2018-04-20 00:00:00
abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/28/2/007
更新日期:2007-02-01 00:00:00
abstract::In electrical impedance tomography (EIT) two-dimensional models continue to be applied despite their known inability to provide correct reconstruction. In this paper, a reconstruction algorithm that assumes a translationally invariant conductivity distribution is described. A more precise forward solver is obtained by...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/1/308
更新日期:2000-02-01 00:00:00
abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9e53
更新日期:2020-11-06 00:00:00
abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/1/004
更新日期:1993-02-01 00:00:00
abstract::Previous studies demonstrate that it is possible to evaluate a heart graft rejection condition using a bioimpedance technique by means of an intracavitary catheter. We propose to use a less invasive technique consisting in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S10
更新日期:2011-07-01 00:00:00
abstract::Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/2/013
更新日期:1998-05-01 00:00:00
abstract::The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 3...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/11/N02
更新日期:2011-11-01 00:00:00
abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/30/9/R01
更新日期:2009-09-01 00:00:00
abstract::The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, wa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/11/2307
更新日期:2014-11-01 00:00:00
abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac553
更新日期:2018-06-19 00:00:00
abstract::Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dime...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/3/009
更新日期:1993-08-01 00:00:00
abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/31/5/008
更新日期:2010-05-01 00:00:00
abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac7aa
更新日期:2018-06-25 00:00:00
abstract:OBJECTIVE:Physical activity has been shown to impact future health outcomes in adults, but little is known about the long-term impact of physical activity in toddlers. Accurately measuring the specific types and amounts of physical activity in toddlers will help us to understand, predict, and better affect their future...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab6ebb
更新日期:2020-03-06 00:00:00
abstract::The widening application of automatic external defibrillators (AEDs) presents very strong requirements for external electrocardiogram (ECG) signal analysis. Highly accurate detection of shockable rhythms is required, aimed to approach the maximum of 100% sensitivity and specificity. In a previous study the performance...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/2/302
更新日期:2001-05-01 00:00:00
abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab921d
更新日期:2020-06-30 00:00:00
abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1834
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:Video and sound acquisition and processing technologies have seen great improvements in recent decades, with many applications in the biomedical area. The aim of this paper is to review the overall state of the art of advances within these topics in paediatrics and to evaluate their potential application for ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab0096
更新日期:2019-02-26 00:00:00
abstract::Easily applicable and inexpensive water-specific techniques to evaluate local oedema, swollen tissue problems and fluid retention in humans are not available. In the present investigation a recently constructed non-invasive device for a local measurement of changes in tissue water in human skin and subcutaneous fat (S...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/2/004
更新日期:2004-04-01 00:00:00
abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aab7ac
更新日期:2018-04-26 00:00:00
abstract::Electroneurograms (ENGs) from the vagus nerve (VN), the splanchnic nerve (SN) and the pancreatic nerve (PN) innervating the pancreas of a dog, were recorded with chronically implanted 33-electrode spiral cuffs (cuff) before and after the pancreas were stimulated with intravenously (i.v.) administered glucose. In the c...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/4/309
更新日期:2002-11-01 00:00:00
abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/37/3/418
更新日期:2016-03-01 00:00:00
abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/2/357
更新日期:2003-05-01 00:00:00
abstract::The objective of this study was to adapt a novel near-infrared diffuse correlation spectroscopy (DCS) flow-oximeter for simultaneous and continuous monitoring of relative changes in cerebral blood flow (rCBF) and cerebral oxygenation (i.e. oxygenated/deoxygenated/total hemoglobin concentration: Δ[HbO2]/Δ[Hb]/ΔTHC) dur...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/10/2135
更新日期:2014-10-01 00:00:00
abstract::Epidemiological studies have associated the negative effects of sedentary time and sedentary patterns on health indices. However, these studies have used methodologies that do not directly measure the sedentary state. Recent technological developments in the area of motion sensors have incorporated inclinometers, whic...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/11/1887
更新日期:2012-11-01 00:00:00
abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/6/022
更新日期:2005-12-01 00:00:00
abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/5/807
更新日期:2014-05-01 00:00:00
abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/26/2/003
更新日期:2005-04-01 00:00:00
abstract::Despite significant advances in adult clinical electrocardiography (ECG) signal processing techniques and the power of digital processors, the analysis of non-invasive foetal ECG (NI-FECG) is still in its infancy. The Physionet/Computing in Cardiology Challenge 2013 addresses some of these limitations by making a set ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/8/1569
更新日期:2014-08-01 00:00:00