Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

Abstract:

:The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patients (M:F 19:6,) were studied, and further subdivided into two groups of patients, one group with a high BMI (25 kg m-2) and the other with a low BMI (<25 kg m-2). Segmental (arm, trunk, leg) and wrist-to-ankle bioimpedance measurements on each patient were performed using a modified Xitron 4000B system (Xitron Technologies, San Diego, CA). No differences in extracellular resistance (R(E), ohms) between wrist-to-ankle (R(W)) and sum of segments (R(S)) were noted for either the high BMI (489.2+/-82 ohm versus 491.6+/-82 ohm, p=ns) or low BMI groups (560.8+/-77 ohm versus 557.5+/-75 ohm, p=ns). UF volume (UFV, liters) did not differ significantly between the groups (4.0+/-0.9 L versus 3.3+/-1.0 L, p=ns), but change in ECV (DeltaECV) differed not only between methods: WBIA versus SBIA in the high BMI group (2.74+/-1.1 L versus 3.64+/-1.4 L, p<0.001) and in the low BMI group (1.86+/-0.9 L versus 2.91+/-1.0 L, p<0.05) but also between the high and lower BMI groups with WBIA (2.74+/-1.1 L versus 1.86+/-0.9 L, p<0.01). However, there was no significant difference in SBIA between BMI groups. This study suggests that the segmental bioimpedance approach may more accurately reflect changes in ECV during HD with UF than whole body impedance measurements.

journal_name

Physiol Meas

authors

Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

doi

10.1088/0967-3334/26/2/009

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

S93-9

issue

2

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(05)86068-X

journal_volume

26

pub_type

临床试验,杂志文章
  • Video rate electrical impedance tomography of vascular changes: preclinical development.

    abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/3/006

    authors: Halter R,Hartov A,Paulsen K

    更新日期:2008-03-01 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • Cooperative dry-electrode sensors for multi-lead biopotential and bioimpedance monitoring.

    abstract::Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a mu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/4/767

    authors: Rapin M,Proença M,Braun F,Meier C,Solà J,Ferrario D,Grossenbacher O,Porchet JA,Chételat O

    更新日期:2015-04-01 00:00:00

  • Detection of acute periodontal pain from physiological signals.

    abstract:OBJECTIVE:To investigate the feasibility of the detection of brief orofacial pain sensations from easily recordable physiological signals by means of machine learning techniques. APPROACH:A total of 47 subjects underwent periodontal probing and indicated each instance of pain perception by means of a push button. Simu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aadf0c

    authors: Teichmann D,Klopp J,Hallmann A,Schuett K,Wolfart S,Teichmann M

    更新日期:2018-09-27 00:00:00

  • Multi-frequency parameter mapping of electrical impedance scanning using two kinds of circuit model.

    abstract::Electrical impedance scanning (EIS) is a kind of potential bio-impedance measurement technology, especially aiding the diagnosis of breast cancer in women. By changing the frequency of the driving signal in turn while keeping the other conditions stable, multi-frequency measurement results on the object can be obtaine...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S07

    authors: Liu R,Dong X,Fu F,You F,Shi X,Ji Z,Wang K

    更新日期:2007-07-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00

  • Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs.

    abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1439

    authors: Svenmarker S,Häggmark S,Johansson G,Axelsson B,Wiklund U,Haney M

    更新日期:2014-07-01 00:00:00

  • Non-invasive measurements of respiratory system mechanical properties by the forced oscillation technique in spontaneously breathing, mixed-breed, normal term lambs from birth to five months of age.

    abstract:OBJECTIVE:To provide a non-invasive approach to monitoring lung function in spontaneously breathing lambs, from birth to five months of life, by the forced oscillation technique (FOT). This report describes the experimental set-up, data processing, and identification of normal predicted values of resistance (Rrs) and r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab3493

    authors: Veneroni C,Dahl MJ,Lavizzari A,Dawson E,Rebentisch A,Studstill S,Bowen S,Albertine KH,Dellaca RL

    更新日期:2019-11-04 00:00:00

  • Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

    abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/4/N01

    authors: Dellacà RL,Gobbi A,Pastena M,Pedotti A,Celli B

    更新日期:2010-04-01 00:00:00

  • Empirical estimators of gamma fits to tracer-dilution curves and their technical basis and practical scope.

    abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/4/401

    authors: Lopatatzidis A,Millard RK

    更新日期:2001-11-01 00:00:00

  • Performance measurements of an infrared digital scanning laser ophthalmoscope.

    abstract::Direct digital acquisition of images using a scanning laser ophthalmoscope (SLO) offers several advantages over the conventional fundus camera; in particular, the ability to produce tomographic images using a confocal aperture. This note describes measurements of the performance of an SLO. Spatial resolution, measured...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/3/010

    authors: Manivannan A,Sharp PF,Forrester JV

    更新日期:1994-08-01 00:00:00

  • Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging.

    abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/12/2529

    authors: Long X,Yang J,Weysen T,Haakma R,Foussier J,Fonseca P,Aarts RM

    更新日期:2014-12-01 00:00:00

  • Development of a novel method for assessing balance: the quantitative posturography system.

    abstract::Balance is the ability to maintain equilibrium while sitting or standing. There are a number of different methods which are used to assess balance: technical methods such as sway magnetometry, ataxia meter and force platforms, and clinical methods such as the functional reach test, Berg balance test and fall risk inde...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/4/309

    authors: Browne J,O'Hare N

    更新日期:2000-11-01 00:00:00

  • A novel curve fitting method for AV optimisation of biventricular pacemakers.

    abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/36/9/1889

    authors: Dehbi HM,Jones S,Sohaib SM,Finegold JA,Siggers JH,Stegemann B,Whinnett ZI,Francis DP

    更新日期:2015-09-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • An electrical impedance tomography system for gynecological application GIT with a tiny electrode array.

    abstract::The paper describes the development of an electrical impedance tomography (EIT) system for gynecologic research. The GIT (gynecological impedance tomography) system has 48 electrodes and is embedded on a small space (30 mm diameter and 20 mm height) inside of the vaginal probe. The system provides real-time (one shot ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/5/849

    authors: V A C,Y V G,A V K,S A S,T S T

    更新日期:2012-05-01 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab7ac

    authors: Ivanović MD,Petrovic J,Savić A,Gligorić G,Miletić M,Vukčević M,Bojović B,Hadžievski L,Allsop T,Webb DJ

    更新日期:2018-04-26 00:00:00

  • Real time impedance plots with arbitrary frequency components.

    abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/1/008

    authors: Searle A,Kirkup L

    更新日期:1999-02-01 00:00:00

  • A new method for measurement of gas exchange during anaesthesia using an extractable marker gas.

    abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/001

    authors: Peyton PJ,Robinson GJ,Terry D,Junor PA

    更新日期:2004-02-01 00:00:00

  • Novel technology to help understand the context of physical activity and sedentary behaviour.

    abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1834

    authors: Loveday A,Sherar LB,Sanders JP,Sanderson PW,Esliger DW

    更新日期:2016-10-01 00:00:00

  • A method for modelling and optimizing an electrical impedance tomography system.

    abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/5/S05

    authors: Hartinger AE,Gagnon H,Guardo R

    更新日期:2006-05-01 00:00:00

  • Adaptive filtering of ECG interference on surface EEnGs based on signal averaging.

    abstract::An external electroenterogram (EEnG) is the recording of the small bowel myoelectrical signal using contact electrodes placed on the abdominal surface. It is a weak signal affected by possible movements and by the interferences of respiration and, principally, of the cardiac signal. In this paper an adaptive filtering...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/6/005

    authors: Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2006-06-01 00:00:00

  • Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients.

    abstract::A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes cl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/11/1931

    authors: Schwenk M,Gogulla S,Englert S,Czempik A,Hauer K

    更新日期:2012-11-01 00:00:00

  • Variability in estimating shunt from single pulse oximetry measurements.

    abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/967

    authors: Karlen W,Petersen CL,Dumont GA,Ansermino JM

    更新日期:2015-05-01 00:00:00

  • Analysis of the quality of wrist movement during a simple tracking task.

    abstract::Objective assessment of stroke-patients' ability to control arm movements is vital for evidence-based therapy and progress monitoring. This study compares three different indices to quantify the quality of wrist movement during a task involving tracking a target on a screen. Each method is assessed in terms of agreeme...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/8/011

    authors: Notley SV,Turk R,Pickering R,Simpson DM,Burridge JH

    更新日期:2007-08-01 00:00:00

  • Age-related changes in pulse risetime measured by multi-site photoplethysmography.

    abstract:OBJECTIVE:It is accepted that changes in the peripheral pulse waveform characteristics occur with ageing. Pulse risetime is one important feature which has clinical value. However, it is unclear how it varies across the full age spectrum from child to senior and for different peripheral measurement sites. The objective...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9b67

    authors: Allen J,O'Sullivan J,Stansby G,Murray A

    更新日期:2020-08-11 00:00:00

  • The feasibility of in vivo quantification of bone-fluorine in humans by delayed neutron activation analysis: a pilot study.

    abstract::Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almos...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/33/2/243

    authors: Chamberlain M,Gräfe JL,Byun SH,Chettle DR,Egden LM,Orchard GM,Webber CE,McNeill FE

    更新日期:2012-02-01 00:00:00